Analog Input Module
Input Type:Thermocouple and / or RTD
Input channels:64 fully-isolated channel-to-channe
Input scan rate:1 Second fixed by IOM
Channel bandwidth:0 to 4.7 Hz (-3 dB)
Nominal input range:-20 to +100 millivolts
Temperature stability:+/-20 ppm per deg C max
Long term drift:500 ppm
Analog Input Module
Extensive self-diagnostics
Optional redundancy
Open Wire Detection
Supplies non-incendive field power
Non-incendive Power
Analog Output Module
Extensive self-diagnostics
Optional redundancy
HART-capable for Status and Configuration
Safe-state (FAILOPT) behaviors configurable
on aper channel basis
Non-incendive output
Analog Input Module
Extensive self-diagnostics
Optional redundancy
Supplies non-incendive field power
Suitable for Configure / Status for HART devices
HART-capable, multivariable instruments for
fastcollection of control variables
Fast loop scan
Non-Incendive Power
CONTROL INTERFACE MODULE
TCPCIC01
DISCONTINUED BY MANUFACTURER
CONTROL INTERFACE MODULE
CNET PCI
5.25 VDC @ 700 MA
CLASS 2
(96365671)
I/O Card
Voltage Rating:24 VDC
Module current rating:430 mA
Operating Temperature:0 to 60 °C
Storage temperature:-40 to 85 °C
Supervisory network type Series:8 PGM is a standard FTE node
Analog Input Module
AI IOTA Redundant
Extensive self-diagnostics
Optional redundancy
Supports either Single Ended / DifferentialInputs
HART-capable, multivariable instruments
and multiplemodems for fast collection of control variables
Fast loop scan

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.