16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Data Rate: Up to 12 Mbps
Isolation:1500 V AC
Power Supply: 24 V DC (±10%)
Power Consumption: Typically 5–10 W
Fieldbus Port: 9-pin D-sub or M12 for PROFIBUS
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity: 5–95% noncondensing
Approvals: CE, TUV, UL, CSA, FM
Number of input channels: 16
Input type: According to DIN (=NAMUR)
Switch level: 1.4-1.9 mA
Hysteresis: 0.2 mA ± 0.05 mA
Field wire resistance: Max. 50 Ω
output voltage 7.9-8.7 V
output current 170 mA (short-circuitproof)3
Maximum load capacitance: 100 nF
Test current: Typically 0.5 mA
Output voltage: Typically 0.5 V DC
Field fault voltage: Max. 250 V AC
Output Channels:32
Output Type SINK: (Open Drain)
Load Current :0.1 A per channel (Max)
On-State Voltage 0v VDC (load current @:0.1A max
Off-State Voltage:24 V (typ),
Off-State Leak Current:100 µA (max)
Turn-On/Turn-Off Time:10 ms (max)
Power supply:24V DC
Rated Current:55mA at 24V
Power Consumption:1.32W at 20mA
Power/DCS to Field:1500 VAC
DCS side connections:
37 pin DSUB connector on CC-UGIA01
Voltage Input:24V DC
Interface to DCS:4 to 20mA with HART
Power supply 24V DC
Rated Current 55mA at 24V
Power Consumption 1.32W
Power/DCS to Field 1500 VAC
DCS side connections 37 pin
DSUB connector on CC-UGIA01
Voltage Input 24V DC
Current Input 4 to 20mA with HART,
CC-UGAI01 in sink mode.
Open wire current <150uA
Type: LCD or TFT color touchscreen
Operating Voltage: 24 VDC (±10%) or 110–230 VAC
Power Consumption: 10–20 W
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5–95% (non-condensing)
Model: SDCS-PIN-H41
Part Number: 3ADT320600R1501
Pulse Voltage: 5–24 V DC
Isolated Pulse Voltage: Typically 10–30 V
Output Current: 1–2 A
Primary-to-Secondary Isolation: ≥2500 V AC
Insulation Resistance: >100 MΩ
Channels: 16 digital channels
Input Type: 24 VDC
Isolation:500 VDC
Update Rate: ≤10 ms
Power Consumption: ≤5 W
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing.
Input Voltage: 24 VDC (±10%)
Output Voltage: 24 VDC
Current Capacity: Typically up to 5A
Operating Temperature: -40°C to +70°C (-40°F to +158°F).
Humidity: 5–95% non-condensing
Voltage Rating: 3.3 kV, 6.6 kV
Control Voltage: 24 VDC
Power Consumption: <20 W
Operating Temperature: 0°C to +55°C
Humidity: Up to 95% RH (non-condensing)
S-Series AO 4-20 mA HART 8-Channel
Local Bus Power 12 VDC at 150 mA
Bussed Field Power 24 VDC at 300 mA
Field Circuit24 VDC at 23 mA/Channel
Ambient Temperature -40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz
0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
S-Series AO 4-20 mA HART 8-Channel
Local Bus Power 12 VDC at 150 mA
Bussed Field Power 24 VDC at 300 mA
Field Circuit24 VDC at 23 mA/Channel
Ambient Temperature -40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz
0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
Input Power Rating 30 VDC @ 1 A
AmbientTemperature-40 °C to +70 °C
Shock 10 g half-sine wave for 11 ms
Vibration 1 mm peak to peak from 2 to 13.2 Hz
0.7 g from 13.2 to 150 Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
Relative Humidity 5 to 95% non-condensing
ANALOG MODULE
2 WIRE/16CHANNEL
4-20MA
SERIES 2
LOCALBUS POWER RATING: 12VDC AT 150MA
BUSSED FIELD POWER RATING: 24VDC AT 600MA
FIELD CIRCUIT RATING: 240VDC AT 30MA
RACK MOUNTED
Input Power Rating 35 VDC @ 500m A
AmbientTemperature-40 °C to +70 °C
Shock 10 g half-sine wave for 11 ms
Vibration 1 mm peak to peak from 2 to 13.2 Hz
0.7 g from 13.2 to 150 Hz
AirborneContaminantsISA-S71.04 –1985 Airborne
Contaminants Class G3
Relative Humidity 5 to 95% non-condensing
Local Bus Power 12 VDC at 300 mA
Fieldbus Power 9 to 32 VDC at 12 mA/Port
AmbientTemperature-40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz;0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 AirborneContaminants Class G3
Relative Humidity 5 to 95% Non-Condensing IP 20 Rating
Terminal Block keyPosition D6
Field Power 35 VDC at 1 A
AmbientTemperature-40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to 13.2Hz;0.7g from 13.2 to 150Hz
AirborneContaminantsISA-S71.04 –1985 AirborneContaminants Class G3
Relative Humidity 5 to 95% Non-Condensing
Terminal Block Key Position Set according to I/O card installed
SERIAL INTERFACE CARD
12 VDC
300 MA
2 PORT
D4 TERMINAL BLOCK KEY POSITION
Simplex SIC (Serial Interface Card),
LocalBus Power Rating 12 VDC 300mA
Ambient Temperature -40 to 70 degrees C