Low Voltage (LV): 380–480V AC
Optional High Voltage (HV):500–690V AC
Short-Circuit Current Rating (I_SC): ≤100 kA
Inrush Current Limit: ≤150% × rated input current
Isolation: ≥2.5 kV
Dynamic braking fuses:690V AC, 100–800A
Ambient Temp Range: -15°C to +45°C
Storage Humidity: ≤95% non-condensing
R8 SINGLE MODULE SP KIT
Forward Voltage: 1200–2500V range
Average On-State Current:500–2000A
Surge Current :10–50 kA
Isolation: ≥2000 V AC
Junction Temperature:>125°C
Supply Voltage:24V DC
Analog Inputs: 0–10 V / 4–20 mA
Communication Ports: Terminals for RS-485
Isolation Rating: ≥1500 V AC
Power Handling: 5-10A
Operating Temperature: -25°C to +70°C
DC Link Voltage Range: 380–525V/690V DC
Current Capacity:50–500 kW
Switching Components:high-power IGBT module
Gate Driver Outputs: 2–16 kHz
Isolation: 2.5 kV
Protocol Support:24V DC signals
Temperature: -10°C to +80°C
Humidity: <95% RH non-condensing
DC Link:1200V
Continuous: 1400A
Pulsed Current: 2000–2800A
Frequency: ≤5 kHz typical
Max. withstand voltage of 1800V
Typical Motor Load: 500–2000 HP induction motors
Voltage Class:1200V
Continuous Current : 650A
Maximum Current: Up to 1300A
Collector-Emitter Saturation Voltage : 2.0–3.0V
Isolation: ≥2500 V DC
Thermal Resistance <0.1°C/W
Voltage: +15V/-8V gate control
Operating Temperature: -40°C to +125°C
Number of inputchannels:8, isolated channels
Input frequency :0 to 10 kHz
Minimum input pulse width:40 µs
Pull-up resistance:68 kΩ (12 V DC or 24 V DC)
Filter:Filter for eliminating chattering can be set
Data update period:2 ms
EC401 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Function: ESB bus interface function
Number of connectable units: Max. 9 units (*1)
Transmission speed: 128 Mbps
Transmission distance: Max. 10 m
Current consumption: 0.5 A
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Actuator Compatibility:spring-return actuators
Supply Pressure Range: 3–30 psi
Input Signal: 4–20 mA
Port Sizes: 1/4" NPT or G1/4 threaded ports
Temperature Range: -40°C to +85°C (-40°F to +185°F)
Ability to de-energizel
Ability to de-energize via secondary meansl
Cross talk between outputsl
Function of the suppression diodesl
Lead breakage in the (external) output wiringl
Short circuit of the outputs
Communication Protocol:Modbus TCP/IP, DeviceNet
Data Rate:Up to 1 Mbps
Power Consumption:L ess than 4W
Operating Temperature:-40C to +70°C
Mounting Type:Panel Mount
ACS880-04 drives
3AXD10000497831
LV AC industrial single drive module
IEC: Pn 500 kW, 715 A, 500 V
UL: Pld 600 Hp, 705 A, 460 V
Number of Phases:3-phase
Enclosure Type NEMA:Open Type
Operating Humidity (RHamb):5 ... 95
Sound dB (A):72 dB(A
Frequency (f): 47.5 ... 63 Hz
Frame Size: R11
Input Voltage (Uin):380 ... 500 V
MotiFlex e180
MFE180-04AN-05A0-4+L518+N8020
3P, 380 VAC
IN: 5 A, HALL incremental encode
A free Mint programming license
easy positioning tasks
drive supports various feedback types
LV AC machinery drive module
IEC: Pn 3 kW, 8 A, 400 V
UL: Pld 5 Hp, 7.6 A, 480 V
(ACS880-M04-08A0-5)
Number of Phases:3-phase
Degree of Protection:IP20
Enclosure Type NEMA:Open Type
Altitude:1000 m
Operating Humidity (RHamb):5 ... 9
Power Factor:0.98
Sound dB (A):47 dB(A)
Output Power: 1.1 kW
Output Voltage: 380–480 V AC, 3-phase ±10%
Continuous current: 4.5 A (at 40°C)
Dynamic peak current: Up to 7.0 A
Input Voltage: 3-phase 380–480 V AC
Input Current (Typ.): 4.6 A @ 480 V AC
Supply Voltage: 24 V DC
Power Consumption: ≤ 5 W
Isolation Voltage: 500 V AC
Voltage range: 0–30 V DC
Logic thresholds: ≤ 5 V DC
Ethernet/IP: TCP/IP, IPv4,
AC Input: 380–480 VAC
DC Input:500–750 VDC
Output Charging Voltage: 24/48/110 VDC
Range: 10–50 A
Current Accuracy: ±1%
Efficiency: ≥92% under full load
Full performance: -10°C to +50°C
Humidity: ≤95% RH (non-condensing)
RS-485 or CAN Bus
Modbus RTU/TCP compatibility
Overvoltage/Undervoltage Protection
Overcurrent Protection
Short-Circuit Protection
Temperature Monitoring with automatic derating
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
68295505
System Voltage:380–500V AC
Frequency Range:10–20 kHz
Filter Topology:LC filters (inductors + capacitors)
Operating Temperature:-15°C to +50°C
ACS880 Liquid-Cooled Multi-Drives
ACS600 Single Drives
VARISTOR UNIT
Protects ACS600 single drives
Protection DutyAC Input Line Transients
Voltage Rating:380–500V AC (50/60 Hz)
Energy Absorption:≥ 120 joules
Clamping Voltage:1.3–1.5x V
Maximum Continuous Voltage:550 V DC link