Backplane (IMB) Supply:20 Vdc to 32 Vdc
Power Dissipation:30 W
Maximum Application Size:960 KB
SOE Buffer:1000 events
Operating Temperature:0 °C to 60 °C (+32 °F to +140 °F)
Storage Temperature: -25 °C to 70 °C (-13 °F to +158 °F)
Input Voltage:24V DC
Output Voltages:+24V DC
Current Capacity:+24V: 2A max
Efficiency:≥85% (full load)
Ripple Noise:<1% of output voltage
Reinforced Isolation :1500V AC input-to-output)
Processor:Dual-core ARM Cortex
Memory:2GB RAM
I/O Capacity:Supports up to 512 I/O points
Power Supply:24V DC
Power Consumption:≤15W (typical)
Ethernet: 2× 10/100/1000 Mbps
Fieldbus: PROFIBUS DP, Modbus TCP/RTU
Outputs per module:32
Galvanic Isolation:2 groups of 16 outputs
Operating Voltage:10.5 to 32 VDC
Output Type:High side driver
Peak Voltage:32 VDC
AC Frequency:N/A
ON Voltage Drop:0.15 VDC @ 0.5 A load
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Operating Voltage:24 V DC
Operating Temperature:-40°C to +85°C (-40°F to +185°F)
Humidity:5–95% RH (non-condensing)
Experience gained from over 100,000 units installed worldwide
Improved reliability
Optional HART® over 4-20mA output
Can detect a wide range of hydrocarbon gases including solvents
Increased reliability with no moving parts
Increased stability from self compensating optics
Immune to long term component drift
Remote functional gas test facility
Response time: T50 < 3 seconds, T90 < 4 seconds (methane)
Operational and certified: -40° to + 65°C temperature range
Number of Phases:3-phase
Degree of Protection:IP21
Enclosure Type NEMA:Type1
Altitude:1000 m
Operating Humidity (RHamb):5 ... 95
Sound dB (A):63 dB(A)
Frequency (f):47.5 ... 63 Hz
Frame Size:R5
Input Voltage (Uin):380 ... 480 V
Input Voltage:24V DC ±10%
Gate Drive Output:+15V/-8V (typical for IGBTs)
Isolation Voltage:2500V AC
Current Sensing Accuracy:±1% of full scale
Switching Frequency:Up to 20kHz
Fiber optic for control signals
Terminal blocks for power connections
Multi-pin headers for auxiliary signals
Emitter Voltage:1700V
Collector Current: 300A @ 80°C
Pulsed Current : Up to 600A
Switching Frequency: Up to 20kHz
Low Saturation Voltage:2.0V
Isolation Voltage: 2500V AC (min)
Supply Voltage: 24V DC (±10%)
Power Consumption: <5W (typical)
Operating Current: 200mA @ 24V DC
Communication Speed: Up to 12Mbps
Optical: ST or BFOC type
Electrical: Terminal block or D-sub
Interface:RS-422/RS-485
Communication function:Half-duplex
Transmission code :ASCII/binary
Character length:7/8 bits
Stop bit length:1/2 bits
Lag time after data transmission:1 ms
Transmission distance:Maximum 1200 m
Number of outputs 16-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 3.4 A minimum
Maximum leak current at output off status 1.6 mA
Output format Current source
Minimum load current 35 mA
Load resistance range 120 to 685 Ω
Output response time 30 ms maximum
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
Rated Current (In): 1 A or 5 A
Current Input: ≤ 0.1 VA
Frequency Range: 45–65 Hz
Binary Inputs: 5 (24–250 V DC/AC)
LED Indicators: 9 (Trip, Start, Alarm, Ready, etc.)
Operating Temperature: -25°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: ≤ 95% RH (non-condensing)
Supply Voltage: 24V DC (±10%)
Power Consumption: 15W typical
Isolation: 500V AC
2x RJ45 Ethernet ports
USB port for local configuration
8 digital inputs (24V DC)
4 digital outputs (24V DC, 0.5A)
2 analog inputs (±10V or 0/4-20mA)
2 analog outputs (0/4-20mA)
Supply Voltage: 24V DC (±10%)
Power Consumption: 2W
Backplane Current: 1A maximum per slot
Isolation: 500V AC
System Connection: S800 bus to main controller
Field Connection: Screw terminals for I/O wiring
Bus Speed: 1.5Mbps
Power Range: 0.55kW
Low Voltage: 380-480V AC
Medium Voltage: 500-690V AC
Input Frequency: 47-63Hz
Output Frequency: 0-300Hz
Overload Capacity: 110% continuous
Digital Outputs: 3 relay (2A/250V AC)
Analog Outputs: 2 (0/4-20mA or 0-10V)
Input Voltage:24V DC nominal
Output Voltage:+5V DC (±1%)
Current Capacity:10A (50W)
Total Power: 170W maximum
Efficiency: >85% at full load
Ripple Noise: <50mV p-p
Reverse polarity protection
Overvoltage protection (35V DC max)
Inrush current limiting
Input16 group isolated and independent channels
Input Range (each channel)0 to 20.4 mA DC (each channel current limited to33 mA)
Accuracy (includes linearity)±0.03% of span
Accuracy temperature coefficient: ±50 ppm/° C
Common Mode Rejection>100 db at 50 or 60 Hz
Normal Mode Rejection>35 db at 50 or 60 Hz
Input Channel Impedance61.9 Ω nominal
INPUT VOLTAGE RANGE (REDUNDANT)24 V DC +5%, -10%
CONSUMPTION7 W (maximum) at 24 V DC11 W (maximum) at 24 V DC with all inputs at20.4 mA (internal power)
Rated Voltage (Vn): 100/110V AC
Burden: <0.2 VA per phase
Rated Current (In): 1A or 5A
Burden: <0.1 VA per phase at In
Digital Inputs: 8–16
Contact Rating: 5A @ 250V AC/DC
Power Consumption: <15W (typical)
3-pole
front operated
base mounted
DIN-rail mountable switch-diconnector
non-fusible diconnect switch
with front protected clamp terminals
handle and shaft are not included
Input Voltage Range: 24V DC
Operating Voltage: 15–30V DC
Current Consumption: 50–200 mA
Isolation Voltage: ≥500V
Analog inputs: ±10V, 4–20mA
Digital inputs :TTL/relay contact