SIMATIC S7-200 SMART
CPU SR20, CPU
AC/DC/relay
onboard I/O: 12DI 24 V DC; 8 DQ relay 2A
power supply: AC 85 - 264 V AC at 47-63 Hz
77 to 138 V DC
program/data memory 20 KB
Brand:GE Fanuc
Series:Versamax
Part Number:IC200PWR001
Product Type:DC Power Supply
Input Voltage:24 Volts DC
Output Voltage:5 Volts DC and 3.3 Volts DC
Input Power:11 Watts
Holdup Time:10 Milliseconds
Total Output:1.5 A maximum
3.3V Output Current:0.25 A maximum
SINAMICS V20
380-480 V 3AC -15%/+10% 47-6
Rated power 0.75 kW with 150% overload for 60 sec
unfiltered I/O interface: 4 DI, 2 DQ, 2 AI, 1 AO
Fieldbus: USS/Modbus
RTU with built-in BOP Degree of protectionIP20/UL
open Size: Size A 90x150x146
Supports a 32-bit 5 V PCI bus
16-bit A/D resolution
Up to 250 kS/s sampling rate
Output voltage: +12 V and -12 V
Resettable fuse protection: 500 mA
Operating temperature: 0˚C to 55˚C
Storage temperature: -20˚C to 80˚C
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Data Rate: Up to 12 Mbps
Isolation:1500 V AC
Power Supply: 24 V DC (±10%)
Power Consumption: Typically 5–10 W
Fieldbus Port: 9-pin D-sub or M12 for PROFIBUS
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity: 5–95% noncondensing
Series:ControlLogix
Inputs:16 Individually Isolated; SOE
Input Voltage:125 Volts DC Sink-Source
Operating Voltage Range:90-140 Volts DC
Maximum Input Current, Off-State:0.3 milliamps
Power Dissipation (Max):5.5 Watts at 60 degrees Celsius
Module Type:Digital Isolated Input Module Series of Events
Series:ControlLogix
Module Type:Diagnostic Input Module
Inputs:8 Diagnostic
Input Voltage:120 Volts AC
Operating Voltage Range:79-132 Volts AC
Input Delay Time:Programmable 9 or 18 milliseconds
Minimum Operating Current:5 milliamperes at 79 Volts AC
Maximum Operating Current:16 milliamperes at 132 Volts AC
Maximum Input Current, Off-State2.5 milliamperes
Range of product:Easy Altivar 610
Product or component type:Variable speed drive
Device short name:ATV610
Variant:Standard version
type of cooling:Forced convection
Supply frequency:50...60 Hz +/-5 %
Network number of phases:3 phases
rated supply voltage:380...460 V - 15...10 %
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:367 Amps, 200kW ND, 160kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:260 Amps, 132kW ND, 110kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:260 Amps, 132kW ND, 110kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
Manufacturer:Rockwell Automation
Product Family:PanelView Plus 6 Operator Terminal
Memory:512 MB Flash/ 512 MB RAM
Compatible Hardware:PanelView Plus 6 700-1500
Status indicators:Red and Green LED
Interfaces:Ethernet port, serial port, two USB ports
CompactFlash card slot
Marine Certified:Yes
Operating Temperature:0-55 Degree Celsius
Power input:24VDC
Power Dissipation:70 Watts
Approvals: CE, TUV, UL, CSA, FM
Number of input channels: 16
Input type: According to DIN (=NAMUR)
Switch level: 1.4-1.9 mA
Hysteresis: 0.2 mA ± 0.05 mA
Field wire resistance: Max. 50 Ω
output voltage 7.9-8.7 V
output current 170 mA (short-circuitproof)3
Maximum load capacitance: 100 nF
Test current: Typically 0.5 mA
Output voltage: Typically 0.5 V DC
Field fault voltage: Max. 250 V AC
Output Channels:32
Output Type SINK: (Open Drain)
Load Current :0.1 A per channel (Max)
On-State Voltage 0v VDC (load current @:0.1A max
Off-State Voltage:24 V (typ),
Off-State Leak Current:100 µA (max)
Turn-On/Turn-Off Time:10 ms (max)
Power supply:24V DC
Rated Current:55mA at 24V
Power Consumption:1.32W at 20mA
Power/DCS to Field:1500 VAC
DCS side connections:
37 pin DSUB connector on CC-UGIA01
Voltage Input:24V DC
Interface to DCS:4 to 20mA with HART
Power supply 24V DC
Rated Current 55mA at 24V
Power Consumption 1.32W
Power/DCS to Field 1500 VAC
DCS side connections 37 pin
DSUB connector on CC-UGIA01
Voltage Input 24V DC
Current Input 4 to 20mA with HART,
CC-UGAI01 in sink mode.
Open wire current <150uA
Two-conductor 18 AWGtwisted,
shielded cable withright angle
two-socket plugat one end,
terminal lugs atthe other end.
Used withmonitors and with
21128Velocity Transducer Housing.Min.
length: 2.0 ft (0.6 m)
Max. length: 99 ft (30 m)
Outputs:16-Points
Module Type:Digital AC Output Module
Voltage:120-140 Volts AC
No. of Outputs Sixteen (16) mechanically fused
Voltage Category:120 / 240 Volts AC
Operating Voltage Range:74-265 Volts AC
Backplane Current at 5 Volts:400 mA