Enclosure: Plastic
Mounting: Onto a standard mounting rail
Settings: Via drive interface (control panel)
Current Consumption: 70 mA at 24 V d.c
All materials are UL/CSA approved
Complies with EMC Standards EN 50081-2 and EN 50082-2
Power Supply :24 V DC
Module Type : NETA-01 V1.x
Mounting: On to a standard mounting rail
Settings : Through drive parameters and/or DIP switches
Current consumption: 80 mA at 24 V DC ±10%
3 digital inputs
3 + 1 digital outputs
DDCS communication link
+24 VDC (500 mA) to supply auxiliary equipment
isolated firing pulses
voltage measurements
Uc (DC busbar voltage)
Uac (supplyvoltage), synchronisation
heatsink temperature measurement
current measurement
earth fault current measurement
7-segment display
Input Signal Types: Voltage (0-10V, ±10V)
Accuracy: ±0.1% of full scale
Output Resolution: 12-bit or 16-bit
Output Load Resistance: 500Ω max
Voltage Supply Range: 24V DC nominal
Power Consumption: < 10 W
Operating Temperature:-20°C to +60°C
Storage Temperature:-40°C to +85°C
Differential push-pull HTL encoders
Single-ended push-pull HTL encoders
Open collector HTL encoders
Open emitter HTL encoders
+15 V DC ± 20% 200mA (max.)
+24 V DC ± 20% 200mA (max.)
Power Supply Voltage: 24 VDC ± 10%
Power Consumption: Typically less than 2 W
Resolver Excitation Voltage: 4-8 V RMS
Resolver Frequency Range: 2 kHz to 15 kHz
Input Channels: 1 Resolver input
Resolution: 12-bit to 16-bit resolution depending on configuration
Accuracy: ±0.05 degrees
Output voltages:
+5.5 V DC -5%, -8%, 180 mA
+24 V DC ±15%, 150 mA
Maximum cable length:
30 m with a 5 V encoder
(0.5 mm2 cable for power supply)
CH A, CH B, CH Z, CH U, CH V, CH W: RS-422/485,
Device used for controlling andprogramming
Can be attached directly to
the module ordoor of the cabinet
The keys are flat, labeled push-buttons
LCD display: 4x20 characters
Input Voltage: 24V DC
Current Consumption: 100-500mA
Power Rating: Usually around 5-10W
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% non-condensing
Operating Voltage: Typically 24V DC or 48V DC
Current Consumption: 5-10 A
Communication Interface: Ethernet/IP, Modbus
Operating Temperature Range: -20°C to 60°C (-4°F to 140°F)
Storage Temperature Range: -40°C to 85°C (-40°F to 185°F)
Humidity: 5% to 95%, non-condensing
Input Voltage: 24 V DC (typical)
Operating Voltage Range: 18 - 32 V DC
Power Consumption: Typically 2.5 W
Isolation Voltage: 500 V AC
Input Type: Digital (24 V DC)
Digital: 3 kΩ
Digital: 0.5 A per channel
PHARPS32000000
DISCONTINUED BY MANUFACTURER
POWER SUPPLY MODULE
90-264 VAC INPUT
47-63 HZ
11.5 AMP
1150 VA
5/15/24 VDC OUTPUT
Tariff Code: 8504409530
Country of Origin: United States
Input: ±10 V DC, 4–20 mA
Power Supply:24 V DC
Power Consumption: ≤ 15 W
Isolation:1500 V AC
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity:
5–95% non-condensing
Channels:16 Digital Inputs
Voltage Levels:
Input:24 V DC (10–30 V DC range)
Output (Transistor): 24 V DC, ≤0.5 A per channel
Field-to-Logic Isolation: 1.5–2 kV
Operating Temperature: -25°C to +60°C (ambient)
Humidity: ≤95%, non-condensing
Power mounting unit
Mounting:Standard 483-mm (19-in.) cabinet
Storage and transport temperature
–40° to 85°C (–40° to 185°F)
Primary power:120/240 VAC, 24/48 VDC
Regulated DC voltages:+5 VDC, +15 VDC
Vibration:13.2 to 100 Hz