With dual-redundant
pressure clamp terminal block for analog
Rated Voltage: 30 V AC
Current Rating:≤4 A
Contact Resistance:≤10 mΩ
Isolation Voltage:300 V AC
Terminal Material :Tin-plated copper alloy
Operating Temperature:-40°C to +85°C
With dual-redundant
pressure clamp terminal block for analog
Rated Voltage: 30 V AC
Current Rating:≤4 A
Contact Resistance:≤10 mΩ
Isolation Voltage:300 V AC
Terminal Material :Tin-plated copper alloy
Operating Temperature:-40°C to +85°C
With dual-redundant
pressure clamp terminal block
Rated Voltage:300 V AC/DC
Current Rating:10–20 A
Contact Resistance:≤5 mΩ
Isolation Voltage:500 V AC
Contact Material:Tin-plated copper alloy
Operating Temperature:-40°C to +85°C
With dual-redundant
pressure clamp terminal block for digital input
Rated Voltage:300 V AC/DC
Current Rating:10–20 A
Contact Resistance:≤5 mΩ
Isolation Voltage:500 V AC
Contact Material:Tin-plated copper alloy.
Operating Temperature:-40°C to +85°C
With dual-redundant
pressure clamp terminal block for digital input
Rated Voltage:300 V AC/DC
Current Rating:10–20 A
Contact Resistance:≤5 mΩ
Isolation Voltage:500 V AC
Contact Material:Tin-plated copper alloy
Operating Temperature:-40°C to +85°C
Max Collector-Emitter Voltage:1000 V
Rated Collector Current:1700 A
Max Pulsed Current :3000–3400 A
Gate-Emitter Voltage:±20 V
Switching Frequency Range:0.5 kHz – 5 kHz
High speed switching
Voltage drive
Low Inductance module structure
Inverter for Motor Drive
AC and DC Servo Drive Amplifier
Uninterruptible Power Supply
Industrial machines, such as Welding machines
Max Collector-Emitter Voltage:1400 V
Rated Collector Current:120 A
Max Power Dissipation:400–600 W
Gate-Emitter Voltage: ±20 V
Switching Frequency Range:1 kHz – 20 kHz
Temperature:150°C – 175°C
Input Type Current (2-wire or self-powered transmitters)
Input Channels 16 Channels (16 Single Ended)
Common Mode Rejection Ratio, dc to 60 Hz 70 dB
A/D Converter Resolution 16 bits
Input Range 4-20 mA (through 200 Ω)
Normal Mode Rejection Ratio, at 60 Hz 20 dB
Normal Mode Filter Response Single-pole RC, -3 dB @ 6.0 Hz
Maximum Normal Mode Input ± 30 Volts
Power Supply: 24 VDC (±10%) or 110–240 VAC
1–2 x RJ45 Ethernet ports.
Serial ports (RS-232/485) for legacy devices
Fiber-optic or coaxial connectors
Operating Temperature: -20°C to +60°C
Humidity: 5–95% non-condensing
Input Type:24V DC
Number of Channels:16 channels per module
Input Voltage Range:ON State: 15–35V DC
OFF State: 0–5V DC
Input Current: Typical: 3–7 mA
Update Rate: ≤ 10 ms
Operating Temperature: -40°C to +70°C (-40°F to +158°F)
Storage Temperature: -40°C to +85°C (-40°F to +185°F)
Rated Load: Up to 1000 kN
Overload Protection: 200% of rated capacity
Accuracy: ±0.1% FS (full-scale linearity).
Output Signal Analog: 4–20 mA (2-wire), ±10V DC
Output Signal Digital: Optional Profibus DP, Modbus RTU
Excitation Voltage: 10–30V DC
Frequency Response: ≤1 kHz
Compression/Tension: Up to 500 kN
Overload Protection: 150% of rated capacity
Accuracy: ±0.1% of full scale (FS) linearity error
Output Signal :Analog: 4–20 mA or ±10V DC
Rated Excitation Voltage: 10–15V DC
Bridge Resistance: 350 Ω ±1%.
Operating Temperature:
-40°C to +120°C (-40°F to +248°F)
Analog Inputs: 8–16 channels
Voltage Ranges: ±10V, 0–10V, 1–5V
Current Ranges: 4–20 mA, 0–20 mA
Analog Outputs: 4–8 channels
Voltage: 0–10V, ±10V
Current: 4–20 mA
Resolution:16-bit ADC/DAC
Inputs per module:8 (isolated)
Input types:mV, V, T/C, RTD, ohms, mA
A/D Converter:One per module
A/D Resolution:15 Bits
Update rate:500ms
Long term Stability:0.1% per year
Inputs per module:16 (sinking)
Input Voltage Range:10 VDC to 32 VDC
Peak Voltage;32 VDC
AC Frequency:N/A
Minimum ON Current:1.0 mA
Maximum OFF Current:0.7 mA
OFF to ON response time:4 ms max
ON to OFF response time:4 ms max
Electronic short circuit protection1 Fast Scan (Priority I/O Module Scan) Safe-state (FAILOPT) behaviors configurable on aper channel basis for Digital / Analog Output HART 7 support (Analog I/O) HART Modem per Channel for Fast Performance Extended Temperature Range -40 to +70°Cmodule ambient
Electronic short circuit protection1
Fast Scan (Priority I/O Module Scan)
Safe-state (FAILOPT) behaviors configurable
on aper channel basis for Digital / Analog Output
HART 7 support (Analog I/O)
HART Modem per Channel for Fast Performance
Extended Temperature Range -40 to +70°Cmodule ambient
Operating Voltage: 24 V DC
Input Current: 1 A
Output Power: 20 W
Bus Interface: RS-485
Operating Temperature: -20°C to +70°C
Humidity Range: 5% to 95% non-condensing
Certifications: CE, UL, ISO 9001
IGCT MODULE
4500V
91MM
ALT PART NUMBER: 5SHY 3545L0016
DC Bus Voltage: 510–930 V DC
Output Current: Up to 600 A
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
ABB SYNCHROTACT 4 multi motor
Voltage Inputs: 3-phase AC, 110–690 V
Frequency Range: 45–65 Hz
Frequency Matching: Precision ±0.01 Hz
Voltage Matching: ≤ ±1% deviation
Operating Temperature: -25°C to +55°C
Input Voltage Range: 230 V AC to 690 V AC
Frequency Range: 0–300 Hz
Efficiency: ≥ 98% under standard load conditions
Operating Temperature: -10°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 5% to 95% (non-condensing)
ACS880 frequency converter drive board
Operating Voltage: 24 Vdc
Analog Inputs: 0–10 V or 4–20 mA
Operating Temperature: -10°C to +50°C
Humidity: 5–95% non-condensing
Output Power: 160 kW (215 HP) at 400 V AC.
Output Current: 302 A
Input: 380–480 V AC, 3-phase (±10%), 50/60 Hz.
Output: 0–480 V AC
Efficiency: ≥97% (typical at full load)
Control I/O: 5x analog inputs (2x 0–10 V / 0–20 mA)
Switching Frequency: 1–8 kHz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC / 4–20 mA
Fieldbus Support: PROFIBUS DP
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F)
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
Input Voltage: 24 VDC (±10%)
Analog Inputs: 0–10 VDC or 4–20 mA
Operating Temperature: -25°C to +55°C (-13°F to +131°F).
Humidity: Up to 95% non-condensing.
Vibration Resistance: 5–150 Hz
RAM: Typically 512 MB to 1 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
RAM: Typically 512 MB to 1 GB
Flash Memory: 2–4 GB
Supply Voltage: 24 VDC (±10%).
Power Consumption: Typically 5–10 W
Operating Temperature: -20°C to +70°C (-4°F to +158°F).
Storage Temperature: -40°C to +85°C (-40°F to +185°F).
Humidity: 5–95% non-condensing
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy