Function: ESB Bus optical transport function
Connection method: Star type connection
Chain type connection
Available for both star and chain type connection.
Number of connecting stage: Maximum two
Transmission distance: Maximum 5 km (total two stages)
In case of Vnet/IP system with the R1.03 or later,
the total distance of two stagesis maximum 10 km.
Current consumption: 0.5 A
Number of output channels 8 channels, module isolation
Rated output range 4 to 20 mA
Maximum range of guaranteed precision 1.25 to 23 mA
Output range 1.25 to 23 mA
Allowable load resistance @ rated range 230 to 600 Ω
Accuracy ±48 µA
Data update frequency 40 ms
Temperature drift ±16 µA/10 ºC
Withstand voltage 1.5 kV AC between output signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
External power supply 24 V DC +20 %/–10 %
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 2 A/output line
Minimum load current 100 mA
Load resistance range 12 to 240 Ω)
Maximum lamp load (*1) 1 A/output line
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of inputs 16-channel, module isolation
Input current 6 mA ± 20 %
Contact rating 24 V DC +20 % / -10 %
External power supply 24 V DC +20 % / -10 %
Input response time 40 ms maximum
Withstand voltage (*1) (*2) 2 kV AC between input signal and system for 1 minute, 16-input line collectivelyconnected
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
Output format Current source
Maximum load current 2 A/output line (8 A in total output lines) (*4)
Minimum load current 100 mA
Load resistance range 12 to 240 Ω (*6)
Analog Inputs:0-10V or 4-20m
Digital Outputs:24V DC
Analog Outputs: 0-10V or 4-20mA
Power Supply:24V DC
Digital Inputs: Typically 8 or 16 digital inputs
Operation method:Unipolar constant current drive
Applied Motor:2-phase stepper motor
Resolution:Intelligent type
Power supply:24-35VDC
Max. Run Current:2A/Phase
Max. Current Consumption:3A
Number Of Axes:1-axis
Environment_Ambient temperature:0 to 50℃, storage: -10 to 60℃
Environment_Ambient humidity:35 to 85% RH, storage: 35 to 85% RH
Dynalco Part No.: LMD-120D
Description: Current Loop-Powered Digital Indicator
Input Signal: 4–20 mA or 10–50 mA, jumper-selectable
Loop Burden: 2 volts maximum, i.e. 100 Ohms at 20 mA
Display: 3½ digits standard;
4½ digits with fixed zero at right-most digit.
Selectable decimal point.
Span and zero adjust:
25-turn potentiometers permit span adjustment from
100 up to 2000 units, and zero adjustment
from – 1000 up to +1000 units
Accuracy: 0.1% linearity,
0.5% stability over the environmental range
Voltage Rating:400V AC
Current Rating:45A at 400V
Frequency Range:0-500 Hz
Input Power: 3-phase 400V AC
Control Inputs/Outputs:0-10V or 4-20mA
Operating temperature range: Typically -10°C to +50°C
Storage temperature range: -40°C to +70°C
User memory:10 megabytes
Safety memory:5 megabytes
Digital I/O / Analog I/O:128,000 / 4000 max
Ethernet performance:10/100/1000 megabits per second
Current draw at 1.2 Volts DC:5.0 milli Amps
Current draw at 5.1 Volts DC:1.2 Amps
Armored and Unarmored Options
Multiple Connector Options
Complete Interchangeability of Units and Cabling
Compact Form Factor
-18 to -24VDC VT
Wide Temperature Range: -55°C to 100°C
11mm Probe Diameter
Aluminum body with 304stainless steel sleeve
28 3300 XL 8mm probe,
selectablehazardous area approvals
05 0.5 m (20 in)
00 Without fittings
023/4-14 NPT
3300 XL 8 mm Probe
3/8-24 UNFthread
without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 11 mm Probe
5/8-18 UNF-2A, without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C
Storage Temperature:-40°C to +85°C
Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C
Storage Temperature:-40°C to +85°C
Input Voltage:24V DC
Current Consumption:Typically 100-200 mA
Fieldbus Power:24V DC
Operating Temperature:Typically -10°C to +60°C
Storage Temperature:-40°C to +85°C
Communication profile CiA 301
Number of installed NFLC121 modules 4 max. for FCN-500
Number of slave devices 126 slave devices per
CANopen Communication Module
Node Bootup
SYNC producer
Heartbeat Consumer/Producer
Number of output channels 16
Rated applied voltage 24 to 125 V DC
100 to 240 V AC, 50/60 Hz
Output response time 12 ms or less
Maximum current consumption 780 mA (5 V DC)
External connection Pressure clamp terminal
Number of input channels 8, isolated channels
Input signal (*1) Contact ON/OFF, voltage pulse
Input frequency 0.1 Hz to 10 kHz
Frequency accuracy 0.1% of reading
Minimum input pulse width 40 μs
Shunt resistance Select from OFF/1000 Ω
Pull-up resistance 68 kΩ (12 V DC or 24 V DC)
Data refresh cycle 10ms
Maximum current consumption 300 mA (5 V DC), 400 mA (24 V DC)
100 to 120 V AC
Duplex configuration: Possible
Hot-Swap: Possible
Rated output: +5.1 V DC, 7.8 A
Analog field power supply: Input: 24 V DC ±10 %, 4 A,
Duplexed (matching-diode)• LED: SYS
(5 V system power output ON)
FLD (24 V field power supply ON)
Checking terminals: +5 V, +24 V
Transmission method Serial communication
Baud rate 128 Mbps
Transmission distance Max. 8 m per line
Extension units Max. 2 units
Duplex configuration Possible
Supplyvoltage 5 V DC±5%
Currentdissipation Max. 500 mA
Rated input voltage:220 to 240 V AC
Input voltage range:170 to 264 V AC (rms)
Input frequency:47 to 66 Hz (Rating: 50/60 Hz)
Input current: Max. 0.7 A
Fuse rating:3.15 A
Leak current Max. :1 mA
Withstanding voltage:3000 V AC for 1 minute
Insulation resistance:50 MΩ at 500 V DC
Input signal 4 to 20 mA
Allowable input current 24 mA
Accuracy ±0.1% of full scale
Overcurrent protection Provided
Data refresh cycle 10 ms
Input step response time 100 ms
Temperature drift Max. ±0.01%/°C
Operation -40 to +70 °C
Transportation/storage -40 to +85 °C
Dust 0.3 mg/m3 or less
Protection class IP20
Altitude 3000 m or less
Electric field 3 V/m or less (26 MHz to 1 GH
Magnetic field 30 A/m (AC) or less, 400 A/m (DC) or less
01 110 to 220 Vac @ 50 to 60 Hz (externalsupply)
00 No display
03 Fiberglass NEMA 4X/IP66 WP housingwith window in door
00 None
00 None
EQUIPMENT MONITOR
GENERAL PURPOSE
1900/65A SERIES