Voltage:Standard 500 V DC
Accuracy: ±5% of reading
Operating Temperature:Typically -10°C to +55°C
Storage Temperature:-20°C to +70°C
Relative Humidity:10% to 95%, non-condensing
Input Voltage:24 V DC or 230 V AC
Single-phase supply 230V +10%/-1
Frequency 50/60
Control signal 0 to 10V
Power supply for possible manual control (+V terminal) 20 Vdc 40
Input Voltage:230 VAC ± 10%, 50/60 Hz
Operating Temperature:0°C to +50°C
Storage Temperature: -20°C to +70°C
Relative Humidity:10% to 90% RH, non-condensing.
Power Supply Voltage:24 VDC
Analog Input Channel :4 channels per module
Analog Input Range: ±10V
Digital Data Range :±2000
Resolution :12 bits (1LSB=5 mV)
Input Impedance :200 KΩ and above
Response Time: 3 ms × channels
Absolution Input Range :±15 V
Analog Output Range: 0~10V
Digital Data Range :0~4000
Temperature Range: Typically -50°C to 300°C
Accuracy: ±0.1°C
Input Voltage: 100-240 VAC, 50/60 Hz
Output Type:4-20 mA or 0-10 V
Operating Temperature Range: Typically -10°C to +60°C
Storage Temperature Range: Typically -20°C to +70°C
Housing design (light emission) Cylindrical
Housing length 70.2 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0.05 m ... 7 m
Sensing range 0.05 m ... 6 m
Type of light Visible red light
Light source LED
Adjustment Potentiometer, 270
Operating temperature range: 0...+ 100°C
Operating frequency range: 0...15 kHz (-3dB)
Displacement measuring range: 2,15 mm
Sensitivity: 7,87 V/mm (200 mV/mil)
Mean voltage: -10,00 V
Power supply: -24 V nominal
Standard cable: 4 - core (4 x 0,2 mm2)
Operating Voltage:120/230 V AC
Current Rating :16 A
Power Output :1.6 kW
Communication Interface:Profibus DP
Control Signals:Up to 16 digital inputs and outputs
Temperature Range:-25°C to 55°C
SIMATIC S7-1500
Analog I/O modules
Fully modular connection
Connection module
at DC / rated value 24 V
rated value 50 V
at DC / maximum 50 V
current / rated value 1 A
during operation 0 ... 60 °C
during storage -40 ... +70 °C
SIMATIC S7-1500
mounting rail 245 mm (approx. 9.6 inch)
incl. grounding screw
integrated DIN rail for mounting of
incidentals such as terminals
automatic circuit breakers and relays
SIMATIC S7-1500
CPU 1511-1 PN
central processing unit with work
memory 300 KB for program
and 1.5 MB for data, 1st interface
PROFINET IRT with 2-port switch
25 ns bit performance
SIMATIC Memory Card
Processor1.2 GHz AMD G Series Quad Core
Operating SystemVxWorks
Power requirementsInput Power (Max) - 20 Watts,
Input Voltage (Min) - 18 VDC
Input Voltage (Max) - 30 VDC
DisplayOLED
SecuritySecure Boot and Trusted Platform Module (TPM)
MarineABS, DNV-GL, BV, LR
Processor1.2 GHz AMD G Series Quad Core
Operating SystemVxWorks
Power requirementsInput Power (Max) - 20 Watts,
Input Voltage (Min) - 18 VDC
Input Voltage (Max) - 30 VDC
DisplayOLED
SecuritySecure Boot and Trusted Platform Module (TPM)
MarineABS, DNV-GL, BV, LR
Product type designation DQ 8x24VDC/2A HF
HW functional status FS03
Firmware version V2.2.0
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Current consumption, max. 40 mA
Rated value (DC) 24 V
Power available from the backplane bus 0.9 W
SIMATIC S7-1500 Analog input module
AI 8xU/I/R/RTD BA
16 bit resolution,Accuracy 0.5%, 8 channels in groups of 8
Common mode voltage 4 V DC,Diagnostics
Hardware interrupts; Delivery including infeed element
shield bracketand shield terminal
Front connector (screw terminals or push-in)
to be orderedseparately
The thinner cable is the signal cable.
It connects theSEMD or MEMD to the mastering box.
The thicker cableis the EtherCAT cable.
It is connected to the mastering boxand to the robot at X32.
Description of adjusting set withSEMD and MEMD
(Micro Electronic Mastering Device)
21000 aluminum probe housing assembly
A dome cover that screws into the body of the housing
Threaded ports for conduit connections
A probe sleeve of optional lengthl 0-rings
A reverse mount proximity probe
A thread seall Optional conduit fittings
An optional standoff adapter
Series:PACSystem RX3i
Product Description Rackless: CPU
RAM:64 MB
Operating System:VxWorks
Flash Memory:64 MB
Operating system:VxWorks
No. of Program blocks:768 Program block
Input Power Requirement:20 Watts
Maximum Program block size 128 KB
Display:OLED
Local display:OLED display
Rated Voltage: 230 VAC
Frequency: 50/60 Hz
Rated Current: Approximately 0.22 A
Power Consumption: ~50 W
Maximum Speed: 2800 RPM
Operating Temperature Range: -25°C to +55°C
Product specific application:Complex machines
Format of the drive:Compact
Mounting mode:Wall mount
rated supply voltage:380...500 V - 15...10 %
Nominal output current:5.5 A
Motor power kW:2.2 kW for heavy duty
Discrete input number:7
Transient overtorque:170…200 % of nominal motor torque
Number of inputs 16-channel, module isolatio
Input current 6 mA ± 20 %
Contact rating 24 V DC +20 % / -10 %
External power supply 24 V DC +20 % / -10 %
Instantaneous maximum permissibleinput voltage 30.0 V DC
Input response time 40 ms maximum
Number of input channels 16 channels, module isolatio
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum