SIPART PS2 Smart
electropneumatic positioner
4...20mA, HART, Ex/nEx
double-acting, polycarbonate enclosure
for pneumatic linear and part-turn actuators
Non-contacting (wear-free) position detection (NCS)
Standard Without explosion protection
Connection thread el.: M20x1.5 / pneu
G 1/4 Without limit monitor.
Without option module
SIRIUS soft starter S00 17.6 A
7.5 kW/400 V
40 °C 200-480 V AC
24 V AC/DC Screw terminals
product brand name SIRIUS
product designation Soft starter
degree of pollution 3, acc. to IEC 60947-4-2
AC Power Input:90-250VAC@200mA
Power Output:Voltage: 24VDC±5%
Current: 800mA
Isolation:1000VAC
Fuse:2.0A, 250VAC
Capacity:Each TM900 can power up to 5 DTM’s
Temperature:
Operation: -40oC to +75oC
Storage: -50oC to +100oC
Humidity:90% non-condensing
Product Type : Standard 8mm Probe
Standard 8mm Probe : M10×1; without armor
Probe Type : 07
Unthreaded Length : 00 = 0 mm
Case Length : 04 = 40 mm
Total Length : 10 = 1.0 m
Connect or Type : 02 = Yes
Power Supply Voltage:24 VDC nominal
Output Signal:4-20 mA
Frequency Response:10 Hz to 10 kHz (-3 dB)
Gain Accuracy:±1% of full scale
Operating Temperature:
-40°C to +85°C (-40°F to +185°F)
Storage Temperature:
-50°C to +90°C (-58°F to +194°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 3 W
Analog Output:4-20 mA
Frequency Response:10 Hz to 1 kHz (-3 dB)
Operating Temperature:
-40°C to +85°C (-40°F to +185°F)
Storage Temperature:
-50°C to +90°C (-58°F to +194°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 5 W
Analog Output:4-20 mA
Frequency Response:2 Hz to 10 kHz (-3 dB)
Operating Temperature:-20°C to +70°C (-4°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Power Supply Voltage:24 VDC nominal
Power Consumption:≤ 5 W
Analog Output:4-20 mA
Frequency Response:2 Hz to 10 kHz (-3 dB)
Operating Temperature:-20°C to +70°C (-4°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Power Supply Voltage:24 VDC (nominal), ±10%
Power Consumption:≤ 5 W
Current Output:4-20 mA
Frequency Response:0.5 Hz to 10 kHz (-3 dB)
Operating Temperature:
-20°C to +70°C (-4°F to +158°F)
Storage Temperature:
-40°C to +85°C (-40°F to +185°F)
Power Supply:Voltage: -23 to -30VDC
Sensitivity:3.94 mV/um (100mV/mil)
Linear Range:
4.0mm (160mils)
begins at 0.40mm (16mils)
fromprobe surface (AISI4140)
Range is 0.40 - 4.40mm (16 - 173 mils)
Frequency Response (±3db):0 - 3.0 kHz
Power Supply Voltage:
24 VDC (nominal), with ±10% tolerance
Power Consumption:≤ 10 W
Signal Input Channels:4 to 16 channels
Vibration: 4-20 mA or 0-5 VDC.
Proximity Probe: -24 VDC signal bias.
Temperature: RTD or Thermocouple
Power Rating:5.5 kW
Phase:3
Supply Voltage:400 V ac
Current Rating:13.8 A
For Use With:AC Motors
Series:ACS310
Field Bus Communication Type:ModBus
IP Rating:IP20
Output Frequency:0 → 500Hz
STO:No
Drive Type:AC
Mounting Type:Module For Cabinet Building
Power Supply: 3-phase 380-480V AC, 50/60 Hz
Output Voltage: Adjustable from 0 to input voltage
Output Frequency Range: 0 to 320 Hz
Rated Power: 22 kW
Current Rating: 47.5 A
Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C
Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C
Type: Tachometer Card
Series: SADC
Input Type:0-10 V or 4-20 mA output
Input Voltage Range:0 to 10 V DC
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C
Input Voltage Range: 24 V DC
Number of Inputs: 32 discrete inputs
Operating Voltage: 24 V DC
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity Range: Typically 5% to 95%
Input Voltage: 24V DC (nominal)
Power Consumption: Typically 10W
Operating Temperature: -15°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 0 to 95% RH, non-condensing
Powermonitor 3000
Master Module with
3-Phase metering & setpoints & I/O
Data logging
5 Amps, Control Power
120V/240V AC 50/60- Hz or
125V/250V DC
Revenue metering
compliance to 1% Accuracy
I/O module:16 digital inputs 24 VDC in 4 groups
Status indicators:I/O function per channel
Operation:0 to 60°C
Storage:-25 to 70°C
Nominal voltage:24 VDC
Hardware:≤12 ms
Switchable displaysk
Text or bar graph displayk
8 limit comparatorsk
4 setpointsk
2 parameter setsk
Maths and logic modulek
Ramp and profile program function
Concept:Transparent Ready
Port Ethernet:10/100BASE-TX - 8 port(s) copper cable
Supply voltage limits:9.6…32 V DC SELV
Power consumption in W:6 W
Alarm output:1 voltfree contact 1 A
Ambient air temperature for operation:0…60 °C
rated supply voltage:12...24 V
Load cell supply 5 V alternating current supply
Input signal 0 15 mV
Sensitivity 0.6 μV / d
Unit kg, g, t, lb, N, kN
Linearity error <0.05 ‰ / 10 K
Range stability,TKc<0.04 ‰ / 10 K
Power Supply:Typically 5 to 24 VDC
Current Consumption:Typical: 40 mA
Operating Temperature:
-10°C to +70°C (14°F to 158°F)
Storage Temperature:
-20°C to +85°C (-4°F to 185°F)
Input Voltage:110/220 VAC or 24 VDC
Frequency Range:50 Hz or 60 Hz
Operating Temperature:
-20°C to +60°C (-4°F to +140°F)
Storage Temperature:
-40°C to +85°C (-40°F to +185°F)
Humidity:
5–95% RH
Input Voltage:110/220 VAC or 24 VDC
Frequency Range:50 Hz or 60 Hz
Frequency: ±10%
Operating Temperature:-10°C to +60°C (14°F to 140°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Humidity:5–95% RH
Input Voltage Range: 0–30 VDC
Output Voltage Range: 0–30 VDC
Output Current: Up to 2 A per channel
Input Voltage: 24 VDC ±10%
Power Consumption: ≤10 W
Operating Temperature: -40°C to +85°C
Storage Temperature: -55°C to +100°C
Humidity: 5–95% RH
Input Voltage Range: 0–30 VDC
Output Voltage Range: 0–30 VDC
Output Current: Up to 2 A per channel
Input Voltage: 24 VDC ±10%
Power Consumption: ≤10 W
Operating Temperature: -40°C to +85°C
Storage Temperature: -55°C to +100°C
Humidity: 5–95% RH
Analog Inputs:0–10 VDC or 4–20 mA
Relay Outputs:250 VAC, 8 A
Power Supply: 24 VDC ±10%
Power Consumption: <10 W
Operating Temperature: -20°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% RH
Enhanced display with local operator interface (LOI)
LCD display
Integral transient protection
Enhanced accuracy and stability
Transmitter-sensor matching with
Callendar-Van Dusenconstants
Variety of enclosures
Power Supply: 24 VAC/DC ±10%, 50/60 Hz
Rated voltage: 250 VAC
Maximum current: 8 A
Operating Temperature: -10°C to +60°C
Storage Temperature: -20°C to +70°C
Humidity: 10% to 90% RH
Power supply 24 VDC (12 to 35 V)
Output signal 4 to 20 mA / 2-wire
Load 0 to 1000 Ohm (35 V)
Accuracy Thermocouple at 25 °C ±2 °C (ITS-90)
Output shift by ambient temperature ±0.005 %
Operating ambient temperature -40 to +125 °C
Chipset type:Intel 945GME at 533 MHz
Display size:15 inch
Display colour:16 million colours
Luminance:350 cd/m²
Supply voltage limits:85…265 V
Inrush current:40 A
Power consumption in W:130 W
Material:Treated steel