Processor module
CPU module ME203/EN (33MHz)
8MB DRAM / 512kB SRAM
8MB file-flash
1x Eth100
1x RS232
1x RS232/422/485
Integrated power supply 17W
PCC slot
CPU module
CPU module 386EX (33MHz)
8MB DRAM / 512kB SRAM
8MB file-flash
1x CAN/CANopen
1x RS232
1x RS232/422/485
Integrated power supply 17W
PCC slot
Serial Interface Module
4 interfaces on one module
Any number of interfaces possible per controller
RS232 / RS422 / RS485 can be combined
High speed interfaces with up to 1.5 Mbaud
Auto-flow control for automatic handshake
Integrated terminating resistors (connect/disconnect)
Interfaces galvanically isolated
Galvanic isolation from system and between interfaces 500 V
LCD Screen Display Panel
TFT-LCD
200-600 cd/m²
Usually between 0°C and 50°C
Typically between -20°C and 60°C
I/O MODULE
E3L020
INPUT/OUT MODULE
16-WAY
16 X 24 VDC
40 MA INPUTS OR OUTPUTS. EACH WAY FREELY PROGRAMMABLE
CAN BE USED IN CONJUNCTION WITH Z3B171 TO PROVIDE 250 VAC / 10 A CONTROL OUTPUTS
LCD display panel
6 O’clock
1/144 Duty Cycle, 1/12 Bias
3.0 Volt (typ.)
14.5 Volt
240 x 128 Dots
White, LED, Long-Lifetime
Touch screen
Renata 950 mAh
Lithium ion
0.8 µs
Resolution 1 s
448 kB FlashPROM
1024 kB FlashPROM
300 kB SRAM
115.2 kbit/s
9-pin male DSUB connector
I/O function per channel, status
ControlNet Bridge Module
ControlNet Bridge Module
5 megabits-second
970 milliamps at 5.1 Volts DC, 1.7 milliamps at 24 Volts DC
17.4 BTU per Hour
5.1 Watts
0.57 pounds (0.26 kilograms)
PXI Matrix Switch Module
512-Crosspoint Matrix in a Single 3U PXI Slot
2,000 Cycles/S
Onboard Relay Count Tracking
Sixteen 2x16 Matrix Banks for Custom Matrix Configurations
Multiple-Module Synchronization with Hardware Triggers
TERMINATION CABLE 8FT
TERMINATION UNIT CABLE
I/O Modules Termination
I/O Module to Termination Unit Cable
TERMINATION CABLE 18FT
TERMINATION UNIT CABLE
I/O Modules Termination
Infi 90 Termination Cable Assy
I/O Module to Termination Unit Cabl
CABLE TERMINATION LOOP 19FEET
TRMNTN UNIT CABLE
19FT
I/O Module to TU Cable
I/O Module to Termination Unit Cable
3300 XL 8 mm Proximity Transducer
3300 XL 8 mm Proximity Probes
4 - 4 mm
54- 540mm
2 - 1.0 metre (3.3 feet)
11 - Miniature coaxial ClickLoc connector, FluidLoc cable
Agency Approval Option: 00 - Not required
Standard Interconnect Cables
Cable length option in feet: -32 - 32 ft
Input : Accepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.
Requires +12 to +35 Vdc input at the transmitter terminal.
Maximum Loop Resistance : 1,000 Ω including cable at 35 Vdc.
Conductors:2 twisted pairs, 22 AWG
Jacket:PUR (Polyurethane)
Capacitance:≤ 100 pF/m (typical).
3300 XL 8 mm Proximity Transducer
330104 3300 XL 8 mm Probe,
M10 x 1 thread,with armor
Minimum unthreaded length: 140 mm
Minimum case length: 190 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
3300 XL 8 mm Proximity Transducer
69.9 pF/m (21.3 pF/ft)
0.787 V/mm (20 mV/mil)nominal
45 g/m (0.5 oz/ft)
-35°C to +200°C (-31°F to+392°F)
+250 °C (482 °F) max for lessthan 24 hours
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.