Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
Order Code:3BHE019958R0101
Functional Designation:UA D206 A
Power Supply:5 V DC
Consumption: 500 mA (max)
Data Rate:300 bps – 115.2 kbps (per port)
Isolation:500 V AC
Processor: 1.2 GHz
Power Supply: 24V DC ±10%
Power Consumption: 120W
MTBF: >200,000 hours
Control Loop Speed: 0.5–5 ms (configurable)
Max I/O Points: 5,000 digital / 2,000 analog
Function:16 AI: U, I, RTD, DI
Number of Analog Configurable I/Os:0
Analog Inputs:16
Input Signal:U, I, RTD, DI
Resolution:Analog Input 13 bit
Degree of Protection:Housing IP20
Supply Voltage:24 V DC
Ambient Air Temperature:
Operation 0 ... +60 °C
Storage -40 ... +70 °C
Supply Voltage: 24V DC (±10%), 5A max.
Atomization air pressure control
Fluid flow regulation (via PWM or analog valve)
HV electrostatic control (up to 100 kV)
Solvent purge management
Diagnostic monitoring (clogs, pressure faults)
Power Consumption: 120W (peak)
Range: Typically 20.4 V DC
Series: 83SR Safety Relay System
Channel-to-Backplane/Logic: Yes
Isolation Voltage: Typically 250V AC
Safety Certification: TÜV Rheinland certified
Output Current: 105 A
Integrated Filter: L500
Frame Size: R7
Cooling Method: Air cooling
Voltage:3-phase 380–480 V AC (±10%)
Frequency:47–63 Hz
Input Current:120 A
Motor Power Range:55–75 kW
Apparent Power (S1):89 kVA (at 480 V)
Measurement Range:0–50 kN
Accuracy"±0.5% of full scale (typical)
Digital Option:RS-485 Modbus RTU
Excitation Voltage:10–30 V DC
Bridge Resistance:350 Ω ±1%
Cable Length:Standard 10m
Overload Capacity:150% of rated range
Rated Operational Voltage (Ue):230/400V AC (50/60 Hz)
Rated Insulation Voltage (Ui):500V AC
Rated Current (In):Up to 100A
Short-Circuit Capacity (Icn):10 kA
Mounting Depth:10–120 mm
Material:Galvanized steel
System Voltage:24 V DC (19.2–30 V DC)
Power Consumption:≤ 1.5 W (typical)
Communication Protocol:Profibus DP-V1
Modbus RTU (via FCI module)
Isolation:Galvanic isolation between
Input Channels:16
Input Type:Dry Contact or 24V DC Sourcing
Voltage Range:19–30 V DC
Input Current:3–5 mA per channel
Logic Levels:"1" (ON): +15–30 V DC
"0" (OFF): 0–5 V DC
Response Time:≤ 2 ms (ON/OFF)
Overvoltage Protection:60 V DC (continuous), 75 V DC (1s)
Isolation:1500 V AC
Input Voltage :24 V DC (±20%)
or 48 V DC (±20%)
Analog Inputs:6 channels
Digital Inputs:8 channels
Analog Outputs:4 channels
(0–20 mA / 4–20 mA)
Digital Outputs:6 channels
Processing Speed:32-bit DSP
Communication:RS-485 Modbus RTU, CANopen
Input Channels:16x Binary Inputs
Output Channels:10x Binary Outputs
Contact Rating (Outputs):5A @ 250V AC/30V DC
Input Voltage Ranges:24/48/110/125 V DC
Input Threshold (ON):>70% of rated voltage
Response Time:<10 ms
Isolation Voltage:2.5 kV AC
Power Consumption:≤ 5 W
Isolation Voltage:1.5 kV AC
Power Supply:24 V DC (±15%), 5 W typical
Redundancy:Dual fiber ports
Fiber Interface:2x ST/PC connectors
Data Rate:10 Mbps
Max. Distance:2 km