350045
GENERAL ELECTRIC
BENTLY NEVADA
DIFFERENTIAL EXPANSION THRUST MONITOR
AVAILABLE
REBUILD SURPLUS
NEW
NEVER USED
REPAIR YOURS
24 HOUR RUSH REPAIR
5-10 DAY REPAIR
2 YEAR RADWELL WARRANTY
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum unthreaded length: 50 mm
Minimum case length: 130 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
PowerConsumption 5.8 watts typical
Relay ArcSuppressor250 VrmsInstalled as standard
Relay ContactLife 10,000 cycles
Min SwitchedCurrent 100 mA @ 5 Vdc
Max SwitchedCurrent 5 A
Max SwitchedVoltage 125 Vdc
Series:PACSystem RX3i
Part Number:IC694MDL754
No. of groups:Two (2)
Description:32-Point Output Module
No of Channels:Thirty-Two (32)
Output voltage range:10.2-30.0 VDC
Operating Voltage:12/24 Volts DC
No. of output groups:Two (2)
Output current:0.75 Amps per point
Switching Current:0.75 Amps per Point
No. of channels per group:Sixteen (16), isolated
Response time, maximum (On and Off):0.5 ms
I/O Capacity:32 Discrete Outputs
Product Type:Discrete Output Module
Module Type:Output Module
No. of outputs: Eight (8) Individually Isolated
Input Type:Relay Output
Power Supply Distance rating:8
Communication Cable:8 Point
Voltage Category:AC/DC normally open relay
Shipping Weight:2 pounds
Operating Voltage range:5 to 265V ac 5 to 125V dc
Power Dissipation:3.5 W
Module Type:Safety Partner module
Series:GuardLogix 5560
Current draw @ 5.1 VDC:1200 mA
Current draw @ 24VDC:14 mA
Thermal Dissipation:11.9 BTU/Hr.
Current Draw (5.1 Volts DC):1200 Miliamperes
Current Draw (24 Volts DC);14 Miliamperes
Thermal Dissipation:11.9 BTU per hour
Isolation Voltage:30 Volts Continuous
Isolation Voltage:30 Volts Continuous
Power Dissipation:2.5 Watts
Current Draw (5.1 Volts):800 Miliamperes
Current Draw (1.2 Volts DC):5.0 Miliamperes
Module Type:ControlLogix Controller
Series:ControlLogix
I-O Memory:0.98 MB
User Memory:8 MB
Maximum I-O:128,000
Maximum Analog I-O:4,000
Maximum Digital I-O:128,000
Inputs:6 Isolated Thermocouple, 1 CJC
Module Type:Analog Thermocouple Module
No. of Inputs:Six (6) Point Isolated Thermocouple Inputs
Supported Sensors:B, C, E, J, K, N, R, S, T
Backplane Current (5Volts):250 milliamps
Removeable Terminal Blocks:1756-TBNH, 1756-TBSH
Backplane Current at 24 Volts:2 milliamperes
Power Dissipation (Max):4.3 Watts
1756DNB
BRIDGE SCANNER MODULE
CONTROLLOGIX
DEVICENET
64 NODE
COMMUNICATION RATES 125 KBPS / 500 M MAX / 250 KBPS / 250 M MAX / 500 KBPS / 100 M MAX
Tariff Code: 8517620050
Country of Origin: United States
Analog: 0–10 VDC or 4–20 mA
Response Time: ≤1 ms
Accuracy: ±0.1% of full scale
Supply Voltage: 24 VDC (±10%) or 100–240 VAC
Power Consumption: ≤10 W (typical)
Operating Temperature: 0°C to +55°C (32°F to +131°F).
Humidity: 5–95% non-condensing.