Handheld design
Enhanced 4.3" diagonal anti-glare touchscreen
with color graphic display
Full QWERTY keyboard
On-Demand Help Menus and
teachable device-specific short cuts
Manage device information through PC connection
Integrated multi-language support
SINAMICS POWER MODULE
PM240-2 WITHOUT FILTER
WITH BUILT IN BRAKING CHOPPER
3AC380-480V +10/-10% 47-63HZ
OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S
150% 57S,100% 240S
AMBIENT TEMP -10 TO +50 DEG C
OUTPUT LOW OVERLOAD: 15KW FOR 150% 3S
110% 57S,100% 240S
AMBIENT TEMP -10 TO +40
FSC PROTECTION IP20
WITHOUT CONTROL UNIT AND PANEL APPROVED
FOR CU FIRMWARE- VERSION V4.6
Primary Input Voltage:3AC 380–480V
Input Frequency:50/60Hz
Auxiliary Power:24V DC ±10%
DC Link Operating Voltage Range:510–680V DC
Overvoltage Shutdown Threshold:830V DC
Peak Feedback Current Capability:≤150%
Digital Inputs:14 channels
Input Voltage:100–690V AC/DC
Frequency (AC):45–65 Hz
Starting Current:≤4 In (inrush) at 70%
Output Voltage (Main):25–28V DC
Output Power:Static-rated at 50W sustained
Max. Ripple Peak:300mVp-p at 100% load
Efficiency Efficiency:>90% at nominal load
Internal Part Number: C98043-A7007-L4
Product Description: TSE Module
Product Category: Spare Part
Application Siemens DC Drives
Export Control Regulations: ECCN: N / AL: N
SINAMICS DCM
DC converter for two-quadrant drives
B6Cconnection
Input: 400V 3AC, 174A
controllable: Field rectifierD485/210
MRE-GEEF6S22
Output: 485 V DC, 210 A
Product Type:Brake Board
Series:MICROMASTER 440
Voltage Range:up to 800 VDC
Operating Temperature:-10 °C to +50 °C
Storage Temperature:-40 °C to +70 °C
SINAMICS S120
Double Motor Module
input: 600 V DC
output: 400 V 3 AC, 3 A/3 A type of
construction: booksize internal air cooling optimized
pulse patterns and support of the extended
Safety Integrated functions
incl. DRIVE-CLiQ cable
MICROMASTER 440
built-in class A filter 380-480 V
3 AC +10/-10% 47-63 Hz
constant torque 5.5 kW overload 150% 60 s
200% 3 s square-law torque 7.5 kW
245x 185x 195 (HxWxD)
degree of protection IP20
ambient temperature -10+50 °C without AOP/BOP
Single-phase: 120–240V AC
DC bus option: 350V DC
Three-phase: 200–480V AC
Continuous: 1.2‒7.8 kW
Peak Current: Up to 28.5‒45A
Velocity/Compliance loop: 2 kHz
Current loop: ≤0.002 ms
SINAMICS G120
Control Unit CU240B-2
DP B type PROFIBUS DP 4 DI
1 DQ, 1 AI, 1 AQ PTC/KTY/thermoclick
interface USB and SD/MMC
interface degree of protection IP20
ambient temperature 0 to +50 °C
without Power Module
Digital Inputs (DI) : 8 × 24V DC
Digital Outputs:4 × Relay Outputs
AC capacity:≤250V
Operating Voltage DC:+24 VDC +10%
Power Consumption:≤5W
Storage Temperature:-10˚C- +60˚C
SIMOTICS S synchronous servo motor
1FK7 Compact 6.0 Nm, 100K, 4500 rpm 1.74 kW
naturally cooled IM B5 (IM V1, IM V3)
power/signal connector plug rotatable by 270°
ABSOLUTE ENCODER 2048 P/REV (ENCODER A-2048)
WITH DRIVE-CLIQ INTERFACE
PERFORMANCE REDUCTION BY 10% DUE TO
ABSOLUTE ENCODER
PLAIN SHAFT, TOLERANCE N
WITH HOLDING BRAKE DEGREE
OF PROTECTION IP64
Insulation Class:2500 V
Collector (DC Link) Voltage:1200 V
Emitter Voltage:1200 V
Collector Peak:≤1800 A
Isolation (DC Link):≥5.0 kV RMS
Short Circuit Peak Current Limit:≤1.8kA
SIMOTICS S synchronous servo motor
1FK7 Compact 11 Nm
100K 3000 rpm
2.29 kW naturally cooled IM B5 (IM V1, IM V3)
power/signal connector plug rotatable by 270°
ABSOLUTE ENCODER 2048 P/REV (ENCODER A-2048)
WITH DRIVE-CLIQ INTERFACE
PERFORMANCE REDUCTION
BY 10% DUE TO ABSOLUTE ENCODER
PLAIN SHAFT, TOLERANCE N
WITH HOLDING BRAKE DEGREE
OF PROTECTION IP64
SINAMICS G120 CONTROL UNIT
CU240E-2 E-TYPE SAFETY INTEGRATED
STO RS485-INTERFACE
USS-PROTOCOL 6DI, 3DO, 2AI, 2AO
MAX 1F-DI PTC/KTY INTERFACE
USB- AND SD/MMC-INTERFACE
PROTECTION IP20
AMBIENT TEMP 0 TO +50 DEG C
WITHOUT POWER MODULE AND PANEL
IGBT-TRANSISTOR MODULE
PRECHARGING RESISTOR 2 X 18 OHM
Voltage: 1500 V
DC Collector Current:160 A
Rated Pulse Current:320 A
Operating Junction Temperature:-40°C to +150°C
EASYGEN 3200-5P2
Voltage Monitoring: 50–600 V AC
Current Monitoring: 1–5 A
Frequency Range: 40–70 Hz
Digital Inputs: 16
Digital Outputs: 8
Analog I/O: 4–20 mA/0–10 V DC
Operating Temperature: -40°C to +85°C
Storage Temperature: -50°C to +105°C
Input Channels: 8 or 16 channels
Channel-to-channel: 1500 V AC
Field-to-system: 2500 V AC
Current: 4–20 mA, 0–20 mA
Current: 4–20 mA, 0–20 mA
Power Supply: 24 V DC ±10%
Accuracy: ±0.05%
CURRENT TRANSFORMER
2000 AMP
15-24VDC
AC Input Range: 0–2000 A AC
Overload Capacity: 130% of Ipn for 10 sec
DC Voltage or Current:4–20 mA (Two-Wire Loop)
Input Voltage: 15–24 V DC ±10%
Power Consumption: <2 W
Primary Current (Ipn): Range 50–600 A
Secondary Current (Isn):1 A or 5 A
Frequency: 50/60 Hz
Insulation Voltage:720 V AC
Operating: -25°C to +60°C
Storage: -40°C to +70°C
PSB11-BOARD/R3 SIC
HP/MC - SINAMICS COMPONENTS (LD)
Link Voltage (DC): Supports 600/510–720 V D
Output Voltage (AC): Up to 480 V AC 3-phase
Continuous Motor Current: Up to 1,600 A
Peak Current: Short-term 2,500 A
Switching Freq: Up to 5–20 kHz