MOD SYS 10KW IMCS TURBO W/RIO W/AXIS LNK
1394CSJT10TRL
DISCONTINUED BY MANUFACTURER 07/31/2013
SERVO AXIS DRIVE
GMC TURBO SYSTEM MOD
360/480 V AC
50/60 HZ
3 PHASE INPUT VOLTAGE
8/10 KW CONT POWER OUT (360/480V NOM.)
64K MEMORY AND 32-BIT CPU
WITH REMOTE I/O AND AXISLINK
CPU 416-2 DP Processor Module
SIMATIC S7-400
CPU 416-2 1.6 MB
WORKING MEMORY (0.8 MB CODE, 0.8 MB DATA)
1. INTERFACE MPI/DP 12 MBIT/S 2
INTERFACE DP
Profibus Module
MICROMASTER 4
PROFIBUS module
For mechanical reasons,
for MM4 FX/GX the plug
6GK1500-0EA02 must be used
CENTRAL PROCESSING UNIT
CENTRAL PROCESSING UNIT
SIMATIC S7-300
CPU 315-2 PN/DP
256 KB WORKING MEMORY
1ST INTERFACE: MPI/DP 12MBIT/S
2ND INTERFACE: ETHERNET PROFINET
MICRO MEMORY CARD REQUIRED
REPLACED BY: 6ES7315-2EH14-0AB0
CPU 314C-2 PTP Compact CPU With MPI
6ES73146BG030AB0
DISCONTINUED BY MANUFACTURER
COMPACT CPU
24VDC
24 DIGITAL INPUTS
16 DIGITAL OUTPUTS
4 ANALOG INPUTS
2 ANALOG OUTPUTS
96KB INTEGRATED MEMORY
Analog input module
Space requirements: 4 TE, 3 HE (= 4 HP, 3U)
Power requirements: 5 V DC, 35 mA/24 V DC, 35 mA
Number of input channels: 16
Input range: 0-4.1 V
Input resistance: > 1 MΩ
Maximum load capacitance: 100 nF
A/D converter: 12-bit
A/D converter inaccuracy: ± 1 LSB
Module inaccuracy: < 0.25%
Absolute max. input signal: ± 36 V DC
Range 0-4.1 V
RTD Input Module
RESISTANCE TEMPERATURE DETECTOR
8-CHANNEL INPUT
TWO TYPES OF RTD SENSORS: PT100/JPT100
5 VOLT CURRENT CONSUMPTION
18-POINT TERMINAL BLOCK
LED INDICATORS
HART Input, 8 channels
Analog Input Module
AAI143-S03
Analog Input Module
16, isolated
Input signal : 4 to 20 mA
Allowable input current : 24 mA

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.