Backplane - 5-Slot
                                                    
                                                    
                                                        
                                                        1 to 16 module slots
Seamless connection / possible
Stabile mechanics / compact design
Vibration proof fixing of modules
Can be snapped on EN 60715 DIN rail
                                                    
                                                
SERCOS Master Module
                                                    
                                                    
                                                        
                                                        SERCOS 2 Standard IEC 61491
Fiber optic technology
Bus with ring structure
2 Kb x 32 DPRAM
Transfer rates: 2/4/8/16 Mbaud
Cycle times: 62.5 µs to 65 ms
Multiple masters can be synchronized
                                                    
                                                
Digital Input/Output Module
                                                    
                                                    
                                                        
                                                        48/64 or 80 digital channels
16 channels can be configured as input or output
Configurable interrupt inputs
Configurable 32 bit counter
Mode: event counter, incremental encoder, gate measurement, cycle time or frequency measurement
Configurable input filter
PWM output mode for e.g. valve economy mode
Status display for each channel via LED
Supply voltage 18 to 34 VDC
Supply voltage protected against reverse polarity
Cost effective and space saving
                                                    
                                                
Temperature Input Module
                                                    
                                                    
                                                        
                                                        4 analog inputs 
±10 V / ±1 V / 0 to 20 mA
12 inputs for Pt100/Pt1000 sensors
Single-ended or differential inputs for analog signals
2-wire inputs for Pt100/Pt1000 sensors
Resolution 14 bit (AI) / 12 bit (Pt100/Pt1000)
Sample time 2.5 ms (AI) / 480 ms (Pt100/Pt1000)
Channels galvanically isolated from system
Wire break detection for the inputs
Monitoring of the external power supply
                                                    
                                                
FastBus Fx210 Module
                                                    
                                                    
                                                        
                                                        Up to 15 distributed substations
Distances to between 2 stations:
40 m for POF cables
150 m for HCS cables
180 m for special HCS cables
Status display (RUN/ERR) 
and display for fiber type
Minimal signal delay
                                                    
                                                
Digital Input Module
                                                    
                                                    
                                                        
                                                        DI232
DISCONTINUED BY MANUFACTURER
INPUT MODULE DIGITAL
32 INPUTS
SUPPLY 24 VDC.
Tariff Code: 8538907080 
Country of Origin: Germany
                                                    
                                                
MX200 Processor Module w/ 512MB Card
                                                    
                                                    
                                                        
                                                        MX213
PROCESSOR MODULE
CPU MODULE LX700 (266MHZ)
256MN DRAM / 512KB NVRAM
16MB FILE-FLASH
2X ETH100
1 X CAN/CANOPEN
1 X RS232
1 X RS232/422/485
1 X USB2.0
INTEGRATED POWER SIPPLY 17 WATT
CF SLOT
2GB CF CARD
                                                    
                                                
Canopen Master Module
                                                    
                                                    
                                                        
                                                        Up to 4 CM202 modules per M200 controller
Up to 8 CAN networks per controller
Operation mode is selected independently for each network
Node Guarding or Heartbeat protocol for network monitoring
Easy configuration
Monitors for commissioning and diagnosis in SolutionCenter
Extensive API for SDO, LMT, LSS, Emergency messages
Maximum cable length depending on baud rate
Maximum number of network nodes depending on baud rate
Transfer rate 10 Kbaud to 1 Mbaud
Galvanically isolated
Short-circuit-proof
                                                    
                                                
Analog Input/Output Module
                                                    
                                                    
                                                        
                                                        8 analog inputs
8 analog outputs
Connection possibility single-ended or differential
Power supply for up to 4 potentiometers
Temperature inputs for up to 4 Pt100/Pt1000 sensors
2-wire or 4-wire inputs for Pt100/Pt1000 sensors
Wire break detection for the inputs (for voltage and temperature)
Short circuit proof outputs
Overload detection for potentiometer power supplies
Monitoring of the external supply voltage
                                                    
                                                
Master module
                                                    
                                                    
                                                        
                                                        FASTBUS master modules 
with 1 or 2 FO interfaces
FASTBUS slave modules 
with integrated power supply
Up to 15 distributed substations
Connection technology via robust 
Harting PushPull® connector or LC patch cable
Distances to 2000 m via multimode cable
Minimal signal delay
ColdClimate models 
                                                    
                                                
FASTBUS Module
                                                    
                                                    
                                                        
                                                        FASTBUS master modules 
with 1 or 2 FO interfaces
FASTBUS slave modules 
with integrated power supply
Up to 15 distributed substations
Connection technology via robust Harting PushPull
connector or LC patch cable
Distances to 2000 m via multimode cable
Minimal signal delay
ColdClimate models 
                                                    
                                                
                                                    
                                                    
                                                        
                                                        FM211
BACHMANN ELECTRONIC
FASTBUS MASTER MODULE
1FO INTERFACE
HCS/PCF 150M
POF 40M
24VDC
17W
                                                    
                                                
Digital Input/Output Module
                                                    
                                                    
                                                        
                                                        Digital Input/Output Module
Tariff Code: 8538909100
Country of Origin: Germany
                                                    
                                                

 
	
		Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.