ADAPT Aeroderivative Monitor
                                                    
                                                    
                                                        
                                                        Displacement: 0–500 µm peak-to-peak
Velocity: 0–20 mm/s RMS
Acceleration: 0–50 g peak
Frequency Response: 0.5 Hz to 30 kHz
Sampling Rate: Up to 100 kHz 
Operating Temperature: -40°C to +85°C 
                                                    
                                                
Wind Turbine Monitor
                                                    
                                                    
                                                        
                                                        Vibration Velocity: Typical range 0–20 mm/s RMS 
Vibration Acceleration: 0–50 g peak
Frequency Range: 0.5 Hz to 10 kHz
Speed Range: 0–3,000 RPM 
Analog Outputs: 4–20 mA 
Operating Temperature: -40°C to +85°C 
Voltage: 18–30 VDC
Power Consumption: <5 W
                                                    
                                                
Wind Turbine Monitor
                                                    
                                                    
                                                        
                                                        Vibration Velocity: Typical range 0–20 mm/s RMS 
Vibration Acceleration: 0–50 g peak
Frequency Range: 0.5 Hz to 10 kHz
Speed Range: 0–3,000 RPM 
Analog Outputs: 4–20 mA 
Operating Temperature: -40°C to +85°C 
Voltage: 18–30 VDC
Power Consumption: <5 W
                                                    
                                                
Emergency Shutdown Device
                                                    
                                                    
                                                        
                                                        Ethernet-6 Ports:10/100 Mbps
Protocol :TCP/IP
Input Range:18-36 Vdc Voltage
Power Consumption:24 W Typical/35 W Maximum
Closed StateImpedance:57 KΩ Maximum
Open StateImpedance:187 KΩ Minimum
Internal WettingVoltage:10-15 Vdc
Input Resistance:150 KΩ Typical
Faulted InputTolerance:±40 V
                                                    
                                                
Wind Turbine Monitor
                                                    
                                                    
                                                        
                                                        Input Power:24V DC (±10%) or 100–240V AC
Power Consumption:<20W (typical)
Analog Inputs:4–20mA, ±10V, IEPE (2-wire)
Relay Outputs:4x SPDT (5A @ 250V AC)
Communication:Ethernet, Modbus TCP/RTU
                                                    
                                                

 
 
	
		Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.