Rated Operational Voltage (Ue):230/400V AC (50/60 Hz)
Rated Insulation Voltage (Ui):500V AC
Rated Current (In):Up to 100A
Short-Circuit Capacity (Icn):10 kA
Mounting Depth:10–120 mm
Material:Galvanized steel
System Voltage:24 V DC (19.2–30 V DC)
Power Consumption:≤ 1.5 W (typical)
Communication Protocol:Profibus DP-V1
Modbus RTU (via FCI module)
Isolation:Galvanic isolation between
Input Channels:16
Input Type:Dry Contact or 24V DC Sourcing
Voltage Range:19–30 V DC
Input Current:3–5 mA per channel
Logic Levels:"1" (ON): +15–30 V DC
"0" (OFF): 0–5 V DC
Response Time:≤ 2 ms (ON/OFF)
Overvoltage Protection:60 V DC (continuous), 75 V DC (1s)
Isolation:1500 V AC
VALVE POSTITONER
ELECTROPNEUMATIC
SIPART PS 2
2/3/4 WIRE
4-20 MA
WITH HART INTERFACE
SINGLE ACTION
FOR LINEAR AND PART-TURN ACTUATORS
30 V
20 MA
18 UAUX
35 VDC
100 MA MAX
Input Voltage :24 V DC (±20%)
or 48 V DC (±20%)
Analog Inputs:6 channels
Digital Inputs:8 channels
Analog Outputs:4 channels
(0–20 mA / 4–20 mA)
Digital Outputs:6 channels
Processing Speed:32-bit DSP
Communication:RS-485 Modbus RTU, CANopen
330105-02-12-10-02-05
DISCONTINUED BY MANUFACTURER
PROXIMITY PROBE
3300 XL 8 MM
5.0 INCH OVERALL CASE LENGTH
1.0 M (3.3 FT) TOTAL LENGTH
3/8-24 UNF THREAD
WITH ARMOR
Voltage Rating: Typically 300V AC/DC
Impedance: 50Ω or 100Ω for coaxial cables
Insulation: High-temperature thermoplastic
Temperature Range:
Operating: -40°C to +85°C (-40°F to +185°F).
Storage: -50°C to +105°C.
Systems: Designed for Bently Nevada 3500 Series
02 M8 x 1
01 CSA/US/C
Sensitivity3.94mV/mm/s (100 mV/in/s)±5%.
TemperatureSensitivity-14% to +7.5%
Velocity Range 1270 mm/s (50 in/s) peak.
TransverseSensitivityLess than 5% of sensitivity
3-conductor shielded 22 AWG(0.5 mm2)
armored cable with3-socket plug at one end
terminal lugs at the other end.
Minimum length of 3.0 ft (0.9 m)
maximum length of 99 ft (30 m)
330104-06-06-90-02-05
DISCONTINUED BY MANUFACTURER
PROXIMITY PROBE
3300 XL 8 MM
5.0 INCH OVERALL CASE LENGTH
1.0 M (3.3 FT) TOTAL LENGTH
3/8-24 UNF THREAD
WITH ARMOR
3300 NSv Probe
3/8-24 UNF thread
withoutarmor
5.0 metres (16.4 feet)
CN Multiple Approvals
Maximum case length: 9.9 in
Minimum case length: 0.8 in
Example: 2 4 = 2.4 in
085 8.50 metres (335 inches)
00 Without armor
Frequency Response: 0 Hz (DC) to 10 kHz
Noncontacting
Gap-to-Voltage Transducer Systems
Measures Static and Dynamic Distances
0 2 M8 X 1 integral stud
0 5Multiple approvals (CSA, ATEX, IECEx,)
Sensitivity 2.5 mV/m/s2 (25 mV/g) ±5%
AmplitudeLinearity ±1% to 735 m/s2 (75 g) peak
FrequencyResponse10 Hz to 15 kHz
TransverseSensitivity Less than 5% of axial.
MountedResonantFrequencyGreater than 30 kHz
Amplitude ofResonantPeak20 dB maximum
Product Type : 3300 XL Standard Extension Cable
Can add on Certificate Of Origin (COO)
Cable Length Option : 060 = 6.0 metres (19.7 feet)
Connector and Cable Option : 00 = Without stainless steel armor
Agency Approval Option : CN = Approvals country specific (CN Approvals Option Quick Reference Guide and Field Notification Letter are in the download section)
3300 XL 8 mm Probe
3/8-24 UNFthread
with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Minimum case length: 0.2 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Example: 0 4 = 0.4 in
Minimum case length: 16 in
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
10 1.0 meter (3.3 feet)
Input Channels:16x Binary Inputs
Output Channels:10x Binary Outputs
Contact Rating (Outputs):5A @ 250V AC/30V DC
Input Voltage Ranges:24/48/110/125 V DC
Input Threshold (ON):>70% of rated voltage
Response Time:<10 ms
Isolation Voltage:2.5 kV AC
Power Consumption:≤ 5 W
Isolation Voltage:1.5 kV AC
Power Supply:24 V DC (±15%), 5 W typical
Redundancy:Dual fiber ports
Fiber Interface:2x ST/PC connectors
Data Rate:10 Mbps
Max. Distance:2 km
Operating Voltage:24V DC (±10%), 3W typical
Accuracy:±0.5% of full scale
Resolution:0.1% (for bargraph display)
Update Rate:100 ms
Isolation: 1.5 kV AC
MODE Switch: Toggle MAN/AUTO/CAS
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
Minimum case length: 10 mm
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
Control Platform:32-bit RISC processor with FPGA logic
Control Methods:DTC , Scalar, Vector
I/O Capacity:16x DI
Operating Voltage:24 V DC (±10%)
Power Consumption:25 W (typical)
Memory:2 GB Flash (firmware/logs)
Rated System Voltage:3300V AC (2.3–4.16 kV range)
DC Link Voltage:5600V DC (max)
IGCT Control :24x Gate driver channels
Gate Drive Voltage:+20V / -5V
Auxiliary Power:24V DC (±10%), 150W
Isolation Voltage:6 kV AC
Response Time:<2 µs
Product Type : Power Supply Module
Model : SPW481 =
100-120V AC Input Power Supply Module
Standard type with no explosion protection
With ISA Standard G3 and temperature (-20C - 70C)
Input Channels :16 Channels
A/D Converter Resolution:16 bits
Input Range:1 4-20 mA only (through 200 Ω)
Normal Mode Rejection Ratio, at 60 Hz:19 dB
Maximum Normal Mode Input: ± 30 Volts
Crosstalk, dc to 60 Hz (channel-to-channel):-60 dB
Input Scan Rate:50 ms
Power supply:24V DC
Rated Current:55mA at 24V
Power Consumption:1.32W at 20mA
Power/DCS to Field:1500 VAC
DCS side connections:
37 pin DSUB connector on CC-UGIA01
Voltage Input:24V DC
Interface to DCS:4 to 20mA with HART