Resolution 14 bit (16 bitmeasured value averaging)
Averaging of measured values for interference suppression
Wire break detection the inputs
Channels isolated against the system
Monitoring of the external power supply
Cold junction temperature compensated
Control of up to (8) Axes
Point to Point Moves
(20) Digital Inputs
(12) Digital Outputs
(4) Differential Analog Inputs with 12-Bit Resolution
CANopen Protocol for Peer-to-Peer Communications with MintMT Controllers
High-Power, Extra-Compact Controller
8 Standard Control Templates
Flexible Control Logic
Easy setup = front panel or industry's
easiest configuration software
Easy-TuneTM PID self-tuning algorithm
Expandable /0 Options
RS-232 & RS-485 Communication Options
Easy to Install
Rugged, NEMA 4 Packaging
Data Transferred at up to 13.4 MBps
Error Detection
Redundant Transmission Mode for Suppressing Errors
No Processor Overhead
No Processor Involvement in Network Operation
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V, 85A FRAME
SIZE: BOOKSIZE INTERNAL AIR COOLING
OPTIMIZED PULSE SAMPLE
AND SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS INCL
DRIVE-CLIQ CABLE
TELEPERM XP INTERFACE MODULE IM308C
INTERFACE MODULE LOCATED IN THE AP OR EG FOR
THE CONNECTION BETWEEN AP AND ET200
INTELLIGENT FIELD DEVICES,
FOR THE SUPPORT OF
THE CENTRALIZED ENGINEERING OF
THE INTELLIGENT FIELD DEVICES
TELEPERM XP MODULE FUM 210
FOR SENSOR CONDITIONING FAST BINARY SIGNAL ACQUISITION,
OR DRIVE CONTROL SENSOR, MONITORING AND SIGNAL.
MODULE CONDITIONING:
14 CHANGEOVER OR 28 SINGLE CONTACTS
WITH SENSOR SUPPLY AND MONITORING,
28 BINARY INPUTS WITHOUT SENSOR SUPPLY
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Migration of Contronic P, E, 3 to System 800xA with AC 870P
Migration of Maestro UX Operations
Maestro UX and System 800xA Operations in parallel
Evolution of SymBatch to 800xA Batch Management
TELEPERM XP MODULE FUM 211,
BINARY SIGNAL COUPLING MODULE
16 BINARY INPUTS
WITE ELECTRICAL ISOLATION
VIA OCTOCOUPLERS 16 BINARY
OUTPUTS 250 MA (WITH LIMITATION)
STEADY OR FLASHING (8, 2, 0,5 HZ)
SUITABLE TO CONNECT CONSOLE CONTROL TILES.
CAPABLE FOR 2 DESK TILES USE IN SPPA-T200
TELEPERM XP MODULE FUM 210
SENSOR CONDITIONING FAST BINARY SIGNAL ACQUISITION,
OR DRIVE CONTROL SENSOR,
MONITORING AND SIGNAL. MODULE CONDITIONING:
14 CHANGEOVER OR 28 SINGLE CONTACTS
WITH SENSOR SUPPLY AND MONITORING,
28 BINARY INPUTS WITHOUT SENSOR SUPPLY
Series:Series 90-30
Part Number:IC693MDL752
Product type:Digital I/O
Product Description:Discrete output module
Compatibility:GE Fanuc 90-30 PLCs
No of Channels:Thirty-Two (32)
Output points:32
No. of output groups:Four (4)
Output groups:4
Channels per group:Eight (8)
Maximum inrush current:4.6 A for 20 ms
Output connection:2 x 24-pin connectors
Brand:GE Fanuc
Series:Series 90-30
Range:-10 to +10 Volts
Part Number:IC693ALG390
Product Description:Analog Voltage Output
No of Channels:2
External Supply Voltage Range:18 to 30 VDC
External Supply Voltage Ripple:10%
Isolation:1500 Volts RMS field to the logic side
Update Rate:5 ms all channels
Resolution:2.5 mV
Accuracy:+/- 5 mV at 25 degrees Celsius
SIMATIC NET,
DP/AS-INTERFACE LINK ADVANCED;
GATEWAY PROFIBUS
DP/AS-INTERFACE WITH MASTER PROFILE M3, M4 ACC.
TO EXTENDED AS-I SPEC.
V3.0 FOR INTEGRATION IN PROFIBUS DP;
DOUBLE MASTER WITH DISPLAY;
DEGREE OF PROTECTION IP20.
10 HP/7.5 KW 380V to
Inverter 380
480V ±10%
3PH 9.5A
Position control/Digital lock
Programmable logic functions
Two programmable thresholds
Mains dip ride through
Frequency slaving
Catch a spinning motor
Eight preset speeds/accelerations/decelerations
Control Techniques Unidrive
Classic 4kW
Inverter 380...480V AC
3PH 9.5A
Position control/Digital lock
Programmable logic functions
Two programmable thresholds
Mains dip ride through
Frequency slaving
Catch a spinning motor
Eight preset speeds/accelerations/decelerations
Injection and dynamic breaking
For Vnet/IP and FIO, for 19-inch Rack Mountable
100–120 V AC power supply
220–240 V AC power supply
Basic type
LFS1500 Control Function for Field Control Station (for Vnet/IP and FIO)
Power Supply Module
Two modules in case of
dual-redundant configuration.
Power supply to the I/O modules
and supply power to the transmitters
The power supply terminals use M4 screws
FASTBUS master modules with 1 or 2 FO interfaces
FASTBUS slave modules with 1 or 2 FO interfaces
FASTBUS slave modules with integrated power supply
Up to 15 distributed substations
Distances to between 2 stations:
40 m for POF cables
150 m for HCS cables
180 m for special HCS cables
Status display (RUN/ERR) and display for fiber type
Minimal signal delay
2 or 4 analog inputs
Input current 0 to 20 mA
Input impedance 75 Ω
Resolution: 16 bit
Refresh cycle time 250 ms / channel
Galvanic isolation of channels
Galvanic isolation from system
Monitoring of internal voltages
4 interfaces on one module
Any number of interfaces possible per controller
RS232 / RS422 / RS485 can be combined
High speed interfaces with up to 1.5 Mbaud
Auto-flow control for automatic handshake
Integrated terminating resistors (connect/disconnect)
Interfaces galvanically isolated
Galvanic isolation from system and between interfaces 500 V
E3L020
INPUT/OUT MODULE
16-WAY
16 X 24 VDC
40 MA INPUTS OR OUTPUTS. EACH WAY FREELY PROGRAMMABLE
CAN BE USED IN CONJUNCTION WITH Z3B171 TO PROVIDE 250 VAC / 10 A CONTROL OUTPUTS
Renata 950 mAh
Lithium ion
0.8 µs
Resolution 1 s
448 kB FlashPROM
1024 kB FlashPROM
300 kB SRAM
115.2 kbit/s
9-pin male DSUB connector
I/O function per channel, status
330104 3300 XL 8 mm Probe,
M10 x 1 thread,with armor
Minimum unthreaded length: 140 mm
Minimum case length: 190 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
Nominal input voltage range100 V AC ... 240 V AC
Input voltage range 85 V AC ... 264 V AC
Input voltage range AC 85 V AC ... 264 V AC
Input voltage range DC 90 V DC ... 350 V DC
Voltage type of supply voltage AC/DC
Inrush current < 15 A (typical)
Number of phases 1.00
Insulation voltage input/output 4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE500 V DC (routine test)