AC DRIVE
UNIDRIVE SP WITHOUT KEYPAD
1 TO 1000HP
460VAC
200V - 690V
3-PHASE
NEMA 4X (IP66)
MAX CONT OUTPUT CURRENT (HP):
NORMAL DUTY -168A (150HP)
HEAVY DUTY -156A (125HP)
OPEN/CLOSED LOOP & SERVO
DC INJECTION
DYNAMIC BRAKING TRANSISTOR INCLUDED
Digital Inputs/Outputs:
Supports discrete I/O for control and status monitoring.
Analog Inputs/Outputs:
Can include support for continuous analog signals
Operating Temperature: 0°C to 60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95%, non-condensing
RAM: Suitable for real-time
data processing.
Input Voltage: 24V DC or 110-240V AC
Communication Ports: Ethernet, RS232/RS485
Operating Temperature: 0°C to +60°C.
Storage Temperature: -20°C to +80°C.
Humidity: 5% to 95%, non-condensing
Data Transfer Rate: Up to 2.5 Mbps
Dimensions: Standard 6U card size for easy installation
in GE control system racks.
Power Requirements:
Logic Power: +5V DC.
Auxiliary Power: 3.3V DC or as specified by the system.
Power Consumption: <10W (typical).
Connector: Multi-pin slot connectors compatible
Input Channels 16 or more digital inputs,
Output Channels 16 or more digital outputs
Operating Voltage 24 VDC (nominal)
Power Consumption Typically <20 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Type DIN rail or panel mount
Communication Protocols Modbus TCP, Profibus,
EtherCAT, CANopen, and other industrial protocols
Operating Voltage 24 VDC
Power Consumption Typically <20 W
Communication Protocols Modbus TCP,
Profibus, EtherCAT, CANopen,
and other standard industrial protocols
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
and other relevant safety standards
Input Channels Configurable digital and analog inputs
Output Channels Digital and relay outputs
tailored for controlling safety-critical systems
Communication Protocols
Modbus TCP, Profibus,
EtherCAT, CANopen, and
other standard industrial protocols
Safety Certification IEC 61508
SIL2/3, ISO 13849
Processor High-performance processor
with fault tolerance
Operating Voltage 24 VDC
Power Consumption <20 W
Operating Temperature -20°C to +70°C
Storage Temperature -40°C to +85°C
Humidity 5% to 95% non-condensing
Mounting Options DIN rail or panel-mounted
System interconnection cables
connect Safety Manager SC IO modules
to SCA (via an IOTA)
The female 37 position d-sub
connects to channel 1 thru 16
(CN1 position)
or channel 17 thru 32 (CN2 position) of theIOTA
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
Safety Standard Compliance
IEC 61508 SIL3, ISO 13849-1
Operating Voltage 24 VDC
Power Consumption <15 W
Operating Temperature -10°C to +60°C
Storage Temperature -40°C to +85°C
Mounting Options DIN rail or panel mount
Length 30 feet
Shielding Shielded Twisted Pair (STP)
Unshielded Twisted Pair (UTP)
Operating Temperature Range -20°C to +75°C
Storage Temperature Range -40°C to +85°C
Bandwidth Up to 1 Gbps (Cat5e) or 10 Gbps (Cat6)
Impedance 100 Ohms ± 15%
Certifications CE, RoHS, TIA/EIA-568 compliant
Communication Protocol Ethernet
with fault-tolerant mechanisms
Redundancy Support
Dual redundant communication paths
Input Voltage 24 VDC or 120/240 VAC
Power Consumption Low power, typically under 10 W
Operating Temperature Range -20°C to +60°C
Storage Temperature Range -40°C to +85°C
Humidity 5% to 95% non-condensing
37-pole sub-D male connector
(CN1) that must be connected
with (16) RUSIO channelsl 16 sets
of two knife terminals for the sixteen channels
Each channel has a the following knife
terminal connections:l A+ terminal that is the (RUSIO)
signal connection.l A- terminal that is
the common 0 Volt connection.
Temperature -40°C to +75°C
(-40°F to +167°F )
Approvals CE, TUV
DIN EN rails: TS32 / TS35 x 7.5
Input voltage:24 VDC +30/-15%
Input current:10 mA maximum 25 mA
Voltage typically +4.1 VDC
Resistor (R)approximately 2.8 kOhm
Product Type : SM RIO 36 inch Carrier
Operating temperature : -40 .. +70 degC
Storage temperature : -40 .. +85 degC
Relative humidity : 10..95% (non condensing)
Pollution : Pollution degree 2 or better
Approvals : CE; UL pending
Module Type I/O Link Module
Power Supply 24 VDC
Operating Temperature -20°C to +60°C
Storage Temperature -40°C to +85°C
Humidity5% to 95% non-condensing
2x Quad-Core/Dual-Core Intel®
Xeon® LV Processors
Four SO-RDIMMs for up to 1
6GB REG/ ECC memory
Four PCI-Express Gigabit Ethernet ports
64bit/66MHz PMC/PCI-Express x8 XMC
Onboard SATA HDD, CompactFlash and USB NAND flash storage
Input Voltage Range
85-264 VAC / 90-350 VDC
Frequency Range 47-63 Hz
Output Voltage 24 VDC (nominal)
Output Current Up to 10 A
Power Output Capacity 240 W
Efficiency ≥ 90%
Ripple and Noise ≤ 50 mV
IS module power supply carrier 8724-CA-PS
Accommodates one 8920 PSU module
DIN rail or panel mounting
printed wiring board
rugged polycarbonate moulding
32- and 64-slot address capable
CARRIER MOUNTING MODULE:
System Power Supply module: 8920-PS-DC
8920-PS-DC
Power Module-Field Input
24VDC In
5A@12VDC Out
Power for 2/1 (IS) modules
Use2/1 (IS)
modules power with
support for load sharing redundancy
PAC8000 I/O
Power Module-Field Input24VDC In
5A@12VDC Out;
Power for 2/1 (IS) modules
Use2/1 (IS) modules power
with support for load sharing redundancy
PAC8000 Intrinsically Safe module
DC power supply (8 modules)
Input Voltage Range 12-24 VDC
Output Voltage Range 12-24 VDC
Output Current Capacity 0.5A to 2A per channel
Response Time <10 ms for input and output signals
Power Supply 24 VDC
Mounting DIN rail or rack-mountable
Operating Temperature -10°C to 60°C
Storage Temperature -20°C to 85°C
Humidity5% to 95% non-condensing
Series Genius I-O
Part Number IC660BBR100
Product Type Relay Output Block
Output Block Type Normally Closed
Number of Outputs 16
Output Configuration 4 Groups of 4 Outputs Each
Output Voltage Type AC or DC
Power Requirements 87 Milliamps at 115 Volts AC
Series Genius I-O
Part Number IC660BBR100
Product Type Relay Output Block
Output Block Type Normally Closed
Number of Outputs 16
Output Configuration 4 Groups of 4 Outputs Each
Output Voltage Type AC or DC
Power Requirements 87 Milliamps at 115 Volts AC
Input Voltage 24 VDC
Mounting Type Rack-mounted or integrated
within the robot controller system
Connection Types Multi-port connectivity
for cables and communication modules
Operating Temperature-10°C to 55°C
Storage Temperature -25°C to 70°C
Humidity 5% to 95% non-condensing
Input Voltage Range: 24 V DC
Current Consumption:
Depends on the configuration of the I/O channels
Signal Type: Digital
Input Type: 24 V DC
Output Type: Relay contacts or transistor outputs
Relay Output Rating: 30 V DC / 2 A per relay
Channels: 15
Signal Types:
standard current input:4-20 mA
voltage inputs0-5 VDC
Input Range: 0-10 VDC, ±10 VDC,
Signal Conversion: 16-bit
Input Impedance: High input impedance f
or accurate measurements without significant loading.
Input Accuracy: Typically ±0.1%
Operating Temperature: -20°C to +60°C
Channels: 16 or 32
current output:4-20 mA
voltage output:0-10 VDC or ±10 VDC
Output Range:0-10 V, ±10 V, 4-20 mA
Resolution: 16-bit
Accuracy:
±0.1% of full scale for voltage outputs
±0.1% of full scale for current outputs
SIPLUS S7-300
SM 331-20-pole -25...+70°C
with conformal coatingbased on
Analog input isolated 2 AI
Resolution 9/12/14 bits
U/I/thermocouple/resistor
alarm diagnostics
1x 20-pole
Removing/inserting with active backplanebus
Design Euro card
Functionality Valve specific
valve parametersfixed
User software Application parameters from
PC viauser software ProVRD
Operating system MS-DOS
Supply voltage 18...30VDC
Solenoid current ranges 0,8 / 2,7 / 3,5A
Current consumption max. 2,0A
Pre-fuse 1,6 / 3,15A fast
Ambient temperature 0...+50°C
Connection DIN 41612F, 48-pole
Command signal inputs 0...+/- 10V
Analog Inputs:4-20 mA, 0-10 VDC
Digital Inputs/Outputs: TTL, 24 VDC
Power Supply Input: 24 VDC or 48 VDC
Logic Supply: 5 VDC or 3.3 VDC
Operating Temperature: -20°C to +70°C
Storage Temperature: -40°C to +85°C
Analog Inputs 4-20 mA, 0-10 VDC
Digital Inputs/Outputs TTL or 24 VDC
Power Supply Input: 24 VDC or 48 VDC
Operational voltage for logic and I/O circuitry: 5 VDC or 3.3 VDC
Operating Temperature: -20°C to +70°C
Storage Temperature: -40°C to +85°C
Current/Ground Fault Sensing Module
for E300 Overload Relays,
0.5-30A
DIN Rail / Panel Mount,
with Line- and Load-Side Power Conductor Terminals,
Directly Replaces 193-ECPM2
Series A
Operating Temperature 0° to 50° C
Storage Temperature -20° to 80° C
Operating Humidity 5 to 95% (non-condensing)
Air Composition No corrosive gases permitted
Power Budget Requirements 5 VA @ 8--30 VDC
Fuse (external) 10 A time-lag (T)
Buffer for date/time Gold capacitor
Temperature class T4 (Zone 2)
Operating temperature 0 °C...+60 °C
Storage temperature -40 °C...+85 °C
Processor Atom E3815 1.46 GHz
Main 256 MB with ECC
Static RAM 2 MB with ECC
backed up by battery
1 GB on-boad flash memory
SDHC (4 to 32 GB) Class 10
D-sub 9 pins, male (*2)
Full/Half duplex (software settings)
Synchronisation Asynchronous
Operation 0° to 55°C
Transportation/storage 40° to 85°C (*1)
Dust 0.3 mg/m3 or less
Resistance to corrosive gases
ANSI/ISA S71.04 Class G2 (Standard)
(ANSI/ISA S71.04 Class G3, option)
Resistance to vibration
0.15 mm P-P (5 to 58 Hz), 1 G (58 to 150 Hz)
Resistance to shock
15 G, 11 ms
(during power-off, for sine half-waves in XYZ-directions)
Altitude 2000 m or less
High-performance
high-elibility modular controller
Memory with ECC
Low heat dissipation eliminates the need for a fan
Awealth of RAS features -CPU self-diagnostics
temperature monitoring. 1/0 diagnostics, and more
power supply module, local bus (SB bus)
and control network can all be duplexed
and all modules are hot-swappable
Can function as link active schedulers
(L ASs) for low-speed voltage mode (H1)
FOUNDATION Fieldbus segments
and link up FOUNDATION Fieldbus-enabled feld devices
Processor Atom E3815 1.46 GHz
Main 256 MB with ECC
Static RAM 2 MB with ECC
backed up by battery
1 GB on-boad flash memory
SDHC (4 to 32 GB) Class 10
D-sub 9 pins, male (*2)
Full/Half duplex (software settings)
Synchronisation Asynchronous
operating 0 to 60°C ambient
storage -40 to 85°C
Humidity 5% to 95% non condensing
Altitude 10,000 ft (3,000 m)
Vibration 0.015 inch (0.38 mm)
Peak to Peak displacement with 2.5 g peak (max)
accelerationover 5 to 2000 Hz
Shock 0 g, 11 ms duration, half-sine shock pulse
Current +5V @ 0.30A
MC68030 at 25 MHz with MMU
MC68882 at 25 MHz
Data and Instruction, each 256 KByte
On-board via the FGA-002B
16 MByte DRAM with Byte Parity
4 MByte, 32-bit
An electronic converter used
in combination with the VITO probes
HART® communication to tank gauging ATG *2
ATEX KEMA 01ATEX1212
IECEx KEM 05.0014
Kosha certificate; 13-AV4BO-0487
FM I. D. 3015746
CSA certificate 1635480
Nominal Voltage 24 VDC
Type Control Module
Output Signals 32, commoned
Voltage Range 16-32 VDC
Maximum Voltage 36 VDC
Voltage Drop < 2.8 VDC @ 1.7A, typical
Power Module Load < 13 watts
MPC8240 32-bit microprocessor
L1 cache—16KB/16KB MPC60x class
32MB of on-board SDRAM
with optional ECCprotection
Two 32-pin PLCC/CLCC sockets for Flash memory;
upto 1MB capacity for on-board firmware
or userspecified requirements
operating 0 to 60°C ambient
storage -40 to 85°C
Humidity 5% to 95% non condensing
Altitude 10,000 ft (3,000 m)
Vibration 0.015 inch (0.38 mm)
Peak to Peak displacement with 2.5 g peak (max)
accelerationover 5 to 2000 Hz
Shock 0 g, 11 ms duration, half-sine shock pulse
Current +5V @ 0.30A
operating 0 to 60°C ambient
storage -40 to 85°C
Humidity 5% to 95% non condensing
Altitude 10,000 ft (3,000 m)
Vibration 0.015 inch (0.38 mm)
Peak to Peak displacement with 2.5 g peak (max)
accelerationover 5 to 2000 Hz
Shock 0 g, 11 ms duration, half-sine shock pulse
Current +5V @ 0.30A
Holds All 3500 Monitor Modules
Rack Power Supplies
Manufactured in (2) Sizes:
Full-Size Rack and Mini-Rack
Manufactured in (3) Formats:
Panel Mount, Rack Mount, and Bulkhead Mount
7 or 14 Rack Postitions
Architecture: 32-bit RISC
Clock Speed: Up to 1 GHz
Voltage 5V DC or 12V DC
Operating Temperature: 0°C to 60°C.
Storage Temperature: -20°C to 85°C.
Humidity: 10%–90% RH(non-condensing)
A16:D8
Four Full-Duplex Channels
Fully Programmable Synchronous
Asynchronous Operation
RS-232C, RS-423, RS-422A,
and RS-485 Compatible
0 to 1 Mbaud Data Rate
Self-Test Capability
Programmable Interrupt Capability
Modem Control Lines for Each Channel
Uses Four Industry-Standard 25-Pin Subminiature D Connectors
Double Eurocard Form Factor
Four Programmable Baud Rate Generators
(8) Sample-and-Hold
Analog Input Channels
12-Bit A/D Converter
PGA Provides Program-Controlled
Gains of x1, x2, x4, x8 and x16
125 kHz Maximum Scan Rate (Gain = x1)
Dual 128 KB Data Buffers for Analog Inputs / Outputs
Analog Function Generation
Voltage: 5V DC or 24V DC
Operating Temperature: -20°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity: 10%–90% RH
Likely used in industrial control systems
Analog I/O channels
Voltage 24V DC or 5V DC
Operating Temperature: -20°C to 70°C
Storage Temperature: -40°C to 85°C
Humidity: 10–90% RH, non-condensing
8TP-1A865 #A6-4
HDMI, VGA, DVI, or composite
Voltage: Typically 12V DC or 24V DC
Operating Temperature: 0°C to 50°C
Humidity: 10–90% RH, non-condensing