VGA Display Monitor
System Event List
Alarm Event List
All module and channel data
3300 style rack view (API-670)
Current alarm data (quick view)
Nine custom display options
Proximitor I/O Module with Internal Terminations
(4) Channel Monitor
Internal terminations
Dual-level alarms (Alert/Danger)
Dynamic and static measurement
Various "Static Value" Parameters
Accepts Input from Proximity Transducers
Proximitor I/O Module with Internal Terminations
Vibration Transmitter
7 0 7.0 metres (23.0 feet)
0 2 Bulkhead screws
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
Vibration Transmitter
7 0 7.0 metres (23.0 feet)
0 1 35 mm DIN rail clips
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical
Vibration Transmitter
5 0 5.0 metres (16.4 feet)
0 2 Bulkhead screws
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
Vibration Transmitter
5 0 5.0 metres (16.4 feet)
0 2 Bulkhead screws
0 0 Not required
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
Vibration Transmitter
06 0.6-0-0.6 mm
50 5.0 meters (16.4 feet)
01 35 mm DIN-rail clips
05CSA Division 2, ATEX Zone 0
ATEXZone 2 and includes
ABSmaritime approval
Vibration Transmitter
5 0 5.0 metres (16.4 feet)
0 1 35 mm DIN rail clips
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
Vibration Transmitter
0 1 35 mm DIN rail clips
CN CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes ABS maritimeapproval
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
Vibration Transmitter
04 0-4 mils pp (0-100 μm pp)
50 5.0 meters (16.4 feet)
01 35 mm DIN rail clips
5CSA Division 2, ATEX Zone 0
ATEXZone 2 and includes
ABSmaritime approval
3300 XL 8 mm Probe
3300 XL 8 mm Probe
M10 x 1 thread
with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector with connectorprotector,
standard cable
00 Not required
Order in increments of 10 mm
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
PROBE PROXIMITY VIBRATION 8MM
7200 5mm / 8mm Series
Proximity Transducer Systems
Frequency Response:
0 Hz (DC) to 10 kHz
Noncontacting
Gap-to-Voltage Transducer Systems
Measures Static and Dynamic Distances
5 mm and 8 mm Standard Mount Probe
Minimum unthreaded length:0.0 in
Minimum length:60 mm
10 1.0 metre (39 inches)
02 With miniature male coaxial conncctor
3300 XL 8 mm Proximity Probes
330102 3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
Minimum unthreaded length: 0.5 in
Minimum case length: 4.0 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Extension Cable
060 6.0 meters (19.7 feet)
03 Without stainless steel armor
with connector protector
05 Multiple Approvals
3300 NSv Extension Cable
3300 NSv Proximity Probes
330905 3300 NSv Probe
M10X1 thread,without armor
Minimum unthreaded length:0 mm
Maximum length: 250 mm
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required
3300 NSv Probes
330903 3300 NSv Probe
M8 x 1 thread,without armor
Minimum length: 0 mm
Minimum length: 30 mm
10 1.0 meter (3.25 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05Multiple Approvals
Vibration Transmitter
10 0-10 mils pp (0-250 μm pp)
70 7.0 meters (23.0 feet)
01 35 mm DIN rail clips
00 Not required
UNIDRIVE SP MODULAR DRIVE COMPONENT
SPMD 1604
UNIDRIVE SP SPM
3 PHASE MAX CONT
168A, TYP
OUTPUT 160KW
150HP
690VAC +/-10%
DBC,HD
UNIDRIVE SP MODULAR DRIVE COMPONENT
UNIDRIVE SP SPMD
3 PHASE MAX CONT
144A, TYP
OUTPUT 132KW
150HP
690VAC +/-10
SPMA DC IN AC OUT KIT
UNIDRIVE SP SPMD
3 PHASE MAX CONT
125A, TYP
OUTPUT 110KW
125HP
690VAC +/-10
UNIDRIVE SP MODULAR DRIVE COMPONENT
DRIVE
90 / 110 KW
UNIDRIVE SP SPMA
3 PHASE MAX CONT
125A, TYP
OUTPUT 90KW
110HP
125VAC +/-10%
SPMA AC IN AC OUT KIT
SPMA AC IN AC OUT KIT
NO KEYPAD
575VAC
UNIDRIVE SP SPMA
3 PHASE MAX CONT
125A, TYP
OUTPUT 90KW
110HP
125VAC +/-10%

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.