3300 XL 11 mm Extension Cable
                                                    
                                                    
                                                        
                                                        080 8.0 meters (26.2 feet)
01 Armored cable
05 Multiple Approvals
Outputresistance50 Ω
                                                    
                                                
3300 XL 8 mm Proximity
                                                    
                                                    
                                                        
                                                        Tip Diameter: 8 mm
Cable Length: 130 inches (10.8 feet)
Measurement Range: Up to 2 mm (80 mils)
Linear Range: 0.25–2.0 mm (10–80 mils)
Output Sensitivity: -7.87 V/mm (-200 mV/mil)
Frequency Response: 0–10 kHz
                                                    
                                                
16710 Interconnect Cables
                                                    
                                                    
                                                        
                                                        3-conductor shielded 
22 AWG (0.5 mm2) 
armored cable with 3- socket plug at one end, 
terminal lugs at the other end
Minimum length of 3.0 ft (0.9 m),
 maximum length of 99 ft (30 m).
Cable Length Option in feet : 35 = 35ft
                                                    
                                                
3300 5mm Proximity Probes
                                                    
                                                    
                                                        
                                                        330171 3300 5mm Probe
1/4-28 UNFthread, without armor
0 0 = 0.0 in.
Minimum unthreaded length: 20 = 2.0 in
0 5 0.5 meter (1.6 feet)
0 2Miniature coaxial ClickLocconnector
standard cable
0 0 Agency Approval Option
                                                    
                                                
990 Vibration Transmitter
                                                    
                                                    
                                                        
                                                        05 0-5 mils pp (0-125 μm pp)
50 5.0 meters (16.4 feet)
70 7.0 meters (23.0 feet)
01 35 mm DIN rail clips
05CSA Division 2, ATEX Zone 0
ATEXZone 2 and includes 
ABSmaritime approval
                                                    
                                                
3300 NSv Extension Cable
                                                    
                                                    
                                                        
                                                        3300 NSv Extension Cable
060 6.0 meters (19.7 feet)
06 FluidLoc cable without stainlesssteel armor
Extension cabledc resistance
Center conductor: 0.220Ω/m (0.067 Ω/ft)
Shield: 0.066 Ω/m (0.020Ω/ft)
                                                    
                                                
3300 NSv Proximity Probes
                                                    
                                                    
                                                        
                                                        330905  3300 NSv Probe
M10X1 thread,without armor
Minimum unthreaded length:80 mm
Minimum length: 130 mm
10 1.0 meter (39 in)
12 Miniature coaxial ClickLoc connector
FluidLoc cable
                                                    
                                                
3300 NSv Extension Cable
                                                    
                                                    
                                                        
                                                        060 6.0 meters (19.7 feet)
04With stainless steel armor
withFEP jacket
with connectorprotector
05 Multiple Approvals
                                                    
                                                
Interconnect Cable
                                                    
                                                    
                                                        
                                                        Impedance: Probable 50 Ohms
Voltage Rating: ≤30 V DC
Operating Temperature: -40°C to +85°C 
Shielding: Dual-layer (foil + braided shield) for robust EMI/RFI protection
Bend Radius: ≥10x cable diameter
                                                    
                                                
3300 XL Standard Extension Cable
                                                    
                                                    
                                                        
                                                        065 6.5 meters (21.3 feet)
01 With stainless steel armor, withFEP jacket
00 Not Required
                                                    
                                                
Case ExpansionTransducer Systems
                                                    
                                                    
                                                        
                                                        Input Power:+24 Vdc, 30 mA minimum
Input Power:+13.5 to +26 Vdcunregulated
30 mAminimum
Voltage:+1 to +6 Vdc, all models
Output Noise:<10 mV
135613-01 and -11 0.20 V/mm (5.0 V/in)
                                                    
                                                
3300 XL 11 mm Extension Cable
                                                    
                                                    
                                                        
                                                        3300 XL 11 mm Extension Cable 
080 8.0 meters (26.2 feet) 
11 Armored FluidLoc cable
05 Multiple Approvals
                                                    
                                                
Emergency Shutdown Device
                                                    
                                                    
                                                        
                                                        Ethernet-6 Ports:10/100 Mbps
Protocol :TCP/IP
Input Range:18-36 Vdc Voltage
Power Consumption:24 W Typical/35 W Maximum
Closed StateImpedance:57 KΩ Maximum
Open StateImpedance:187 KΩ Minimum
Internal WettingVoltage:10-15 Vdc
Input Resistance:150 KΩ Typical
Faulted InputTolerance:±40 V
                                                    
                                                
Vibration Monitors
                                                    
                                                    
                                                        
                                                        DC Input :18~36 Vdc, max 7.5 W
Scale Factorrange:5 to 1000 mV/g
Full scale range: 2 to 80 g peak
Current SinkSource:3.3 mA ± 5%
Open CircuitVoltage:-21 to -24 Vdc
ConfigurableBandpass filter:0.2 Hz to 20 kHz
Supply Voltage :-22.8 to –25.2 Vdc
Maximum RatedCurrent:15 mA
                                                    
                                                
330103 3300 XL 8 mm Probe
                                                    
                                                    
                                                        
                                                        330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Example: 0 6 = 60 mm
Maximum case length: 250 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
                                                    
                                                
Rack Interface I/O Module
                                                    
                                                    
                                                        
                                                        RIM I/O Module with Modem Interface
Voltage: 24V DC (±10%)
Consumption: ≤15W
Analog Inputs:4–20mA
Digital Inputs:24V DC dry contact
RS-485:Modbus RTU @ 115.2kbps max
                                                    
                                                
TRANSDUCER
                                                    
                                                    
                                                        
                                                        0 1 ¼-28 UNF integral stud
0 5Multiple approvals (CSA, ATEX, IECEx,)
Sensitivity 2.5 mV/m/s2 (25 mV/g) ±5%.
AmplitudeLinearity ±1% to 735 m/s2 (75 g) peak.
TransverseSensitivity Less than 5% of axial.
Amplitude ofResonantPeak20 dB maximum
                                                    
                                                
Interconnect Cable
                                                    
                                                    
                                                        
                                                        Shielding:100% foil/braid shielding
Impedance: 50Ω ±10%
Max Signal Frequency: Up to 20 kHz 
Operating Range: –55°C to +250°C
Flexibility: 500+ flex cycles
Bend Radius: 8x cable diameter 
                                                    
                                                
Control Transformer Module
                                                    
                                                    
                                                        
                                                        Input Voltage:120V AC ±10%
Output Voltage:24V DC regulated
Power Rating: 100VA (typical)
Efficiency: >85% at full load
Isolation: 1500V AC input-to-output
Thermal Protection: Shutdown at >85°C 
                                                    
                                                
Dual Differential Expansion Monitor
                                                    
                                                    
                                                        
                                                        Sensor Input:-24V DC @ 4mA 
Analog Output:4-20mA
Relay Outputs:3 per channel
Communication:RS-485 Modbus RTU (optional)
Measurement Range:±4mm (±0.16 in) standard
Resolution:0.1% of full scale
Frequency Response:DC to 10Hz (-3dB)
Channels:2 fully independent monitoring channels
                                                    
                                                
Dual Accelerometer Monitor
                                                    
                                                    
                                                        
                                                        1 5 0-25 mm/s pk 
1 5 0-25 mm/s pk
val Option0 0 Not required 
0 0 None 
Measures Absolute Machine Housing
Provides Two Independent Channels
Provides Over 10,000 High-Pass and Low-Pass Filter Combinations
                                                    
                                                
Dual Vibration XY/GAP Monitor
                                                    
                                                    
                                                        
                                                        1 5 0-500 µm pp
0 1 3300 8 mm, 3300 XL 8mm 
or7200 5 mm and 8 mm
0 3 7200 11 mm Proximitor®Sensor(not XL), 100 mV/mil 
0 0 No Relays 
0 0 Not required
0 2 Internal 
                                                    
                                                
Proximitor Seismic Monitor
                                                    
                                                    
                                                        
                                                        Signal Accepts from:1 to 4 proximity
velocity or accelerationtransducer signals
Power consumption:7.7 watts, typical
Standard:I/O 10 kΩ
Output Impedance:550 Ω
Transducer Power Supply:-24 Vdc
Voltage Compliance:0 to +12 Vdc range acrossload
                                                    
                                                
3300 XL 11 mm Probe
                                                    
                                                    
                                                        
                                                        330707 3300 XL 11 mm Probe
5/8-18 UNFthread, without armor
Example: 2 40 = 2.0 in
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
                                                    
                                                
3300 XL Proximitor Sensor
                                                    
                                                    
                                                        
                                                        3300 XL Proximitor Sensor
11 1.0 meter (3.3 feet) system length
51 5.0 meters (16.4 feet) system length
91 9.0 meters (29.5 feet) system length
05 CSA, ATEX, IECEx  Approvals
                                                    
                                                

 
	
		Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.