Local or Remote Visual Indication
of 3500 Machinery Protection System
(4) Display Mounting Types
Up to (2) Displays per 3500 Rack
Input Signal: -10 Vdc to +10 Vdc
Power Consumption: 10.5 watts
Ethernet: 100Base-FX Fiber-Optic
Power Consumption:4.75 watts, typical
Standard:RS232 serial communications
Data Rate:38.4 k baud
Normally closed contacts:Arc suppressors are provided
Maximum Current:<1 mA dc, Dry Contact to Common
Signal :Accepts from 1 to 4 proximitytransducer signals
Power consumption :7.7 Watts, typical
Standard I/O: 10 kΩ
Output Impedance:550 Ω
Transducer Power Supply:-24 Vdc
Gap filter:-3 dB at 0.09 Hz
Smax : 0.125 to 15.8 times runningspeed
System Event List
Alarm Event List
All module and channel data
3300 style rack view (API-670)
Current alarm data (quick view)
Nine custom display options
7 0 7.0 metres (23.0 feet)
0 2 Bulkhead screws
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
7 0 7.0 metres (23.0 feet)
0 1 35 mm DIN rail clips
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical
5 0 5.0 metres (16.4 feet)
0 2 Bulkhead screws
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
5 0 5.0 metres (16.4 feet)
0 2 Bulkhead screws
0 0 Not required
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
5 0 5.0 metres (16.4 feet)
0 1 35 mm DIN rail clips
0 5 CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes ABS maritimeapprova
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
5 0 5.0 metres (16.4 feet)
0 1 35 mm DIN rail clips
0 1 CSA Division 2
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
0 1 35 mm DIN rail clips
CN CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes ABS maritimeapproval
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
0 4 0-4 mils pp (0-100 μm pp)
5 0 5.0 metres (16.4 feet)
0 1 35 mm DIN rail clips
0 5 CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes
ABS maritimeapproval
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.
Sensitivity 3.94 mV/mm/s (100 mV/in/s)±5%.
TemperatureSensitivity-8% to +5%
AmplitudeLinearity±2% to 63.5 mm/s pk
MountedResonantFrequency9 kHz, minimum
DynamicOutputImpedance<400 Ω typical
BroadbandNoise Floor 0.229 mm/s (0.009 in/s) pk.
OperatingTemperature-40 °C to +85 °C
StorageTemperature-40 °C to +100 °C
Shock Limit 5000 g pk, maximum.
HumidityLimit100% condensing
3300 XL 8 mm Probe
M10 x 1 thread
with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector with connectorprotector,
standard cable
00 Not required
Order in increments of 10 mm
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
7200 5mm / 8mm Series
Proximity Transducer Systems
Frequency Response:
0 Hz (DC) to 10 kHz
Noncontacting
Gap-to-Voltage Transducer Systems
Measures Static and Dynamic Distances
3300 XL 8 mm Probe
3/8-24 UNFthread
with armor
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector,
standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.
3300 NSv Probe
M8X1 thread
without armor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
Order in increments of 10 mm.
Length configuration:
Maximum unthreaded length:230 mm
Minimum unthreaded length:0 mm
Example:06 = 60 mm
10 0-10 mils pp (0-250 μm pp)
70 7.0 meters (23.0 feet)
01 35 mm DIN rail clips
00 Not required
Operating temperature
-35°C to +85°C(-31°F to +185°F)
Storage temperature
-52°C to +100°C(-62°F to +212°F).
Probe Cable 75Ω coaxial,
fluoroethylenepropylene (FEP) insulated
AC DRIVE
UNIDRIVE SP WITHOUT KEYPAD
1 TO 1000HP
460VAC
200V - 690V
3-PHASE
NEMA 4X (IP66)
MAX CONT OUTPUT CURRENT (HP):
NORMAL DUTY -168A (150HP)
HEAVY DUTY -156A (125HP)
OPEN/CLOSED LOOP & SERVO
DC INJECTION
DYNAMIC BRAKING TRANSISTOR INCLUDED
Digital Inputs/Outputs:
Supports discrete I/O for control and status monitoring.
Analog Inputs/Outputs:
Can include support for continuous analog signals
Operating Temperature: 0°C to 60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95%, non-condensing
RAM: Suitable for real-time
data processing.
Input Voltage: 24V DC or 110-240V AC
Communication Ports: Ethernet, RS232/RS485
Operating Temperature: 0°C to +60°C.
Storage Temperature: -20°C to +80°C.
Humidity: 5% to 95%, non-condensing