3300 XL 8 mm Probe, M10 x 1 thread
without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector, FluidLoc cable
CN CSA, ATEX, IECEx Approvals
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
Product Type : Standard Interconnect Cables
Length : 17 = Minimum length, 17 ft
2-conductor twisted,
shielded 22AWG cable with 2-socketmoisture-resistant
femaleconnector at one end,
terminallugs at the other end.
Used with monitors.
Not for usewith 21128 Velocity Transducer
Housing.Minimum length: 2.0 ft (0.6 m)
Maximum length: 99 ft (30 m)
3300 XL 8 mm Probe, M10 x 1 thread,without armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector, standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
3300 XL 8 mm Probe, M10 x 1 thread,without armor
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector, standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
3300 XL 8 mm Probe, M10 x 1 thread,without armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector, standard cable
05 CSA, ATEX, IECEx Approvals
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
3300 XL 8 mm Probe, M10 x 1 thread,without armor
10 1.0 meter (3.3 feet)
02 Miniature ClickLoc coaxialconnector
05 CSA, ATEX, IECEx Approvals
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
3300 XL 8 mm Probe,
3/8-24 UNFthread
without armor
05 0.5 meter (1.6 feet)
05 CSA, ATEX, IECEx Approvals
02 Miniature coaxial ClickLocconnector, standard cable
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.
Measurement Range: +/- 50 mils (1.27 mm)
Frequency Range: DC to 10 kHz
Output Signal: 4-20 mA
Power Supply: 24 VDC nominal, 18-32 VDC
Temperature Range: -40°C to +85°C
3300 NSv Probe, M10X1 thread, witharmor
Order in increments of 10 mm.
Metric thread configurations:
Maximum length: 250 mm
Minimum length: 20 mm
Example: 06 = 60 mm
Example: 0 4 = 0.4 in.
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector,standard cable
CN Multiple Approvals
3300 XL 8 mm Probe, 3/8-24 UNFthread, with armor
Order in increments of 0.1 in.Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.
10 1.0 meter (3.3 feet)
11 Miniature coaxial ClickLocconnector with connectorprotector, FluidLoc cable
00 Not required
Product No.: 8502-BI-DP
Product Type: Bus Interface Module (BIM)
Protocol: Profibus
Function: Links MTL8000
node to Profibus-DP host LAN
I/O Support: Supports up to 24 I/O modules
Diagnostics: Extended diagnostics
for module and channel status
LAN Speed: Up to 6 Mbaud
Memory: Non-volatile memory for configuration
Input Power Rating 30 VDC @ 100m A
AmbientTemperature-40 °C to +70 °C
Shock 10 g half-sine wave for 11 ms
Vibration
1 mm peak to peak from 2 to 13.2 Hz;
0.7 g from 13.2 to 150 Hz
AirborneContaminants
ISA-S71.04 –1985 Airborne
Contaminants Class G3
Relative Humidity 5 to 95% non-condensing
CHARM Bus power rating +6.3 VDC at 0 mA
Field circuit power rating+24 VDC at 78 mA
AmbientTemperature-40°C to +70°C
Shock 10g ½ Sinewave for 11msec
Vibration 1mm Peak to Peak from 2 to13.2Hz;
0.7g from 13.2 to 150Hz
Airborne Contaminants
ISA-S71.04 –1985 Airborne
Contaminants Class G3
VFD-L Series Drive
Item Category: Drives
Subcategory: AC
Series: VFD-L
Nominal Input VAC: 240 Volts AC
HP (CT): 1 Horsepower
Amps (CT): 4.2 Amps
Input Phase: 1 or 3
Operator Controls: Built In
Max. Frequency: 400 Hertz
Braking Type: DC Injection
Motor Control-Max Level: V/Hz (Scalar)
Closed Loop: No
Operating Temperature -20°C to +80°C
handle temperatures -40°C or as high as +120°C
Humidity Resistance 5% to 95% non-condensing
Damping Force 100 N to 5000 N
GSI 24
GALVANIC SEPARATION
Measuring Range: 0.1 to 1000 Hz
Sensitivity 1 mV/g to 100 mV/g
Operating Voltage 24V DC
Operating Temperature -40°C to +85°C
Signal Type: 4-20 mA or 0-10V
Operating Temperature -20°C to +80°C
handle temperatures -40°C or as high as +120°C
Humidity Resistance 5% to 95% non-condensing
Damping Force 100 N to 5000 N
Operating Temperature -20°C to +80°C
handle temperatures -40°C or as high as +120°C
Humidity Resistance 5% to 95% non-condensing
Damping Force 100 N to 5000 N
Operating Temperature -20°C to +80°C
handle temperatures -40°C or as high as +120°C
Humidity Resistance 5% to 95% non-condensing
Damping Force 100 N to 5000 N
Operating Voltage: +5V DC or +24V DC
Power Consumption: 2W to 15W
Operating Temperature :0°C to +60°C or -20°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% non-condensing
Operating Voltage: +24V DC
Power Consumption: 10W to 30W
Operating Temperature: 0°C to +60°C
Storage Temperature: -20°C to +70°C.
Humidity: Operates in 5% to 95% non-condensing
PC BOARD ASSEMBLY
CMOS MEMORY BOARD
Memory Capacity: 128KB to 1MB
Operating Voltage:operates on +5V DC
Operating Temperature: 0°C to +60°C
Storage Temperature: Typically -40°C to +85°C.
Humidity: Generally 5% to 95% non-condensing
PC BOARD
DIGITIZING INTERFACE BOARD
(502-02777-50)
Analog to Digital Conversion: 4-20mA, 0-10V
4-20mA current loop inputs.
0-10V or 0-5V voltage inputs.
Operating Temperature: -20°C to +70°C
Storage Temperature: -40°C to +85°C.
Humidity: 5% to 95% non-condensing.
Nominal Bus Output Voltage 300V DC
Continuous Current(RMS) 45.0 A
Peak Current(RMS) 90.0 A
Continuous Power Output 15.0 kW
Peak Power Output 30.0 kW
Input Circuit Breaker Rating 38A RMS
Circuit Breaker Interrupt Rating 1300 A
Static Gain 1.5x Rated Motor I/RPM
Input voltage 0 to +30VDC,+24VDC nominal
On state voltage +15 to +30VDC
Off state voltage 0 to +5VDC
Off state current 2.0 to 5.5mA0 to 0.5mA
Off response time 0.5ms maximum
Configurable filtertime0 ms, 1.0ms (default), or 7.0ms
Input impedance 10kOhms maximum
Series: MicroNet Digital Controllers
Flash Memory: 64 MB
Input Voltage: 110 VAC/125 VDC
Features: 10/100 Base T Ethernet
Maximum Stub Length: 300 mm
Dimensions: 9.50 x 10.50 x 1.00
Model: 10BaseT Ethernet Connector
Potential Voltage Range: 80-150
SIMATIC S7-1500
CPU 1517-3 PN/DP
Central processing unit
with work memory2 MB for
Program and 8 MB for data
1st interface: PROFINET IRT with 2-portswitch
2nd interface: PROFINET RT
3rd interface: PROFIBUS
2 ns bitperformance
SIMATIC Memory Card required
SIMATIC S7-400H
412-5H system bundle H-system
with 1 x UR2-H, withoutmemory card
2 x PS407 UC120/230V
10 A, 4 x sync modules up to 10 m
2 xsync cables 1 m
2 x CPU 412-5H
in addition 2 memory cards and
4 backupbatteries required
4 x 0-10V or 4-20mA inputs
High precision A/D conversion
for accurate measurements of pressure
flow, and other hydraulic parameters
4 x 0-10V or 4-20mA outputs
Sampling Rate: 1 kHz
Resolution: 12-bit or 16-bit resolution for analog I/O
Precision: ±0.1% full scale
4 x 0-10V or 4-20mA inputs
High precision A/D conversion
for accurate measurements of pressure
flow, and other hydraulic parameters
4 x 0-10V or 4-20mA outputs
Sampling Rate: 1 kHz
Resolution: 12-bit or 16-bit resolution for analog I/O
Precision: ±0.1% full scale
32 channel
voltage monitor132 V AC or 150 V DC
maximumLogic Zero - 0 to 20 V AC; 0to 20 V DC
Logic One - 80 to 132 V AC;75 to 150 V DC
Input Current for Logic One;2.6 mA
maximumChannel isolation provided by
termination assembly
01 19-inch Rack (14 module slots)
02 Rack Mount Option, Full-Size Rack
(mounts to19-inch EIA Rack)
01 CSA/NRTL/C (Class 1, Division 2)
00 None
01 CE
The 3500/05 mini-rack is not available
in theBulkhead Mount option.
Accepts from 1 to 16 signals
Input impedance: Greater than 1 MΩ
Power consumption: 3 watts
Front panel LEDs: OK, TX/RX, Bypass
Type E, J, K, T thermocouples
100 Ω 3-wire and 4-wire platinum RTD
8 channels AIO208, 16 channels AIO216
Analog inputs and outputs
Filter adjustable from 4 kHz to 0.5 Hz per channel
All outputs overload, short circuit and external voltage-proof
Measuring range monitoring freely adjustable (±105 %)
Error message on overload and overtemperature and undervoltage of the supply
Galvanic isolation from the system 500 V
Modes that can be selected per channel:
Analog voltage input ±10 V to ±10 mV
Analog current input 0(4) to 20 mA