Filter Board
PLC BOARD
FILTER ABSORBER
Up to 24V DC/230V AC
30+ MHz noise frequencies
Leakage Current: Typ. ≤2 mA
Communication components
A5E00242932
SIMATIC S7-300
PROFIBUS DP/MPI
PROFIBUS D-Sub 9-pin
Up to 12 Mbps for PROFIBUS
AC/DC DRIVE MODULE
AC/DC DRIVE
SIMOVERT MASTERDRIVES
890-930 V DC INPUT
660-690 V AC OUTPUT
3 PH
23 KW
1200 AMP
IP00
INTERFACE BOARD
INTERFACE BOARD
TERMINAL BLOCK SE300
FOR TECHNOLOGY MODULE T300
SIMOVERT MASTERDRIVES
Double Motor Module
SINAMICS S120
Double Motor Module
input: 600 V DC
output: 400V 3AC, 18 A/18 A
design: booksize D type
internal air cooling optimized pulse patterns
and support of the extended Safety Integrated
functions incl. DRIVE-CLiQ cable
Control Interface Board
MICROMASTER 430 PX
replacement Control Interface Board
for 380-480 V 3AC
50/60 Hz, 380 A AC Drive
Inverter driver board
SINAMICS S120/S150
Logic-side (control): 24 V DC
Power-side (IGBT control):up to 800 V DC peak
Signal Isolation: ≥2500 V AC
Operating: 0°C to +55°C
Storage: -40°C to +85°C
BRAKING RESISTOR
BRAKING RESISTOR
SINAMICS
160 OHM
4 KW
460 V
FOR POWER MODULE
FSB BASE MOUNTING POSSIBLE
43'' FHD Monitor
Light and cost-effective plastic housing
suitable for continuous 24/7 operation
178°H/178°V extra-wide viewing angle
High fidelity digital processing
8ms fast response time
Support multiple signal inputs
such as HDMI, VGA and USB
Physical button
infrared remote dual control mode
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3-PH 400V, 9A
FRAME SIZE: BOOKSIZE D-TYPE
INTERNAL AIR COOLING OPTIMIZED PULSE
SAMPLE AND SUPPORT OF THE EXTENDED
SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
Velomitor CT Transducer
0 1 Stud 3/8-in 24 to 3/8-in 24
0 0 MIL-C-5015 connection interface
0 1 through CSA/NRTL/C (Class I, Division 1)
ATEX/IECEx/CSA (Class I, Zone0/1)
Interconnect cable
Two-conductor 18 AWGtwisted, shielded cable
withright angle two-socket plugat one end
terminal lugs atthe other end.
Used withmonitors and with 21128Velocity
Transducer Housing
Min. length: 2.0 ft (0.6 m)
Max. length: 99 ft (30 m)
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
3300 XL Standard Extension Cable
075 7.5 meters (24.6 feet)
02 Standard cable with connectorprotector
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
15 1.5 meter (4.9 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
00 Not required
Controller Module
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Motherboard
Input Voltage: 24 V DC
Backplane Power: 5 V DC
RAM Slots: 2× DDR4 SO-DIMM
Storage: Integrated 16 GB flash
Operating: -40°C to +70°C
Humidity: 5–95% non-condensing
MTBF: >250,000 hours
Processor Module
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.