Power Distribution Board
Connectors:4‑pin action‑pin header
Input Voltage:From controller chassis (5 VDC rails)
Mounting:DIN‑rail (TS32/TS35×7.5 mm)
Operating Temp:–40 °C to +70 °C
Humidity:Up to 95% RH, non‑condensing
Safety Manager System Module
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
3300 XL 11 mm Proximity Probes
330707 3300 XL 11 mm Probe
5/8-18 UNFthread, without armor
Minimum unthreaded length:0.0 in
Minimum case length: 2.0 in
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
00 Not required
PROXPAC XL Proximity Transducer
28 3300 XL 8 mm probe withMultiple Approvals
0 4 40 mm
047 47 mm
0 3 One M20 fitting, two plugs
0 23/4-14 NPT
PROXPAC XL Proximity Transducer
28 3300 XL 8 mm probe withMultiple Approvals
00 No standoff adapter
125 12.5 mm
0 7 One PG21 x M20 fitting, two plugs
0 23/4-14 NPT
DIGITAL INPUT MODULE
DIGITAL INPUT MODULE
SIMATIC S5
115V AC/DC
16 INPUTS
ISOLATED FOR S5-115U
Thermocouple Input Module
ANALOG INPUT MODULE
THERMOCOUPLE
8POINT
INDEPENDENT THERMOCOUPLE OR MULTIVOLT INPUTS
50/60HZ
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 3.8 in
Minimum case length: 4.9 in
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 8.0 in
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 7.8 in
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 7.6 in
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 6.1 in
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.4 in
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.3 in
15 1.5 meter (4.9 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Velomitor CT Velocity Transducer
01 Stud 3/8-in 24 to 3/8-in 24
00 MIL-C-5015 connection interface
04CSA/NRTL
Proximity Probe HousingAssemblies
PROXPAC XL Proximity Transducer
1 6 3300 XL 8 mm probe withoutapprovals
0 0 No standoff adapter
Minimum length: 307 mm
0 6One 3/4-14 NPT fitting
one 3/4-14NPT to 1/2-14 NPT
SST reducerand two plugs
0 23/4-14 NPT
PROXPAC XL Proximity Transducer
1 6 3300 XL 8 mm probe withoutapprovals
0 0 No standoff adapter
Minimum length: 200 mm
0 6One 3/4-14 NPT fitting,
one 3/4-14NPT to 1/2-14 NPT
SST reducerand two plugs
0 23/4-14 NPT
Sensor Proximity Probe Cable
Stainless steel armor
overshielded 0.382 mm2 (22 AWG)cable
with a moistureresistant female connector
atthe transducer end and
ringlugs at the monitor end
Temperature range -29 to121°C (-20 to 250°F)
Proximity Probe HousingAssemblies
343300 XL 8mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
Minimum length 2.0 in (50.8 mm)
6.2 in (157.48 mm) = 062
04 One 3/4-14 NPT plug only
023/4-14 NPT
Proximity Probe HousingAssemblies
34 3300 XL 8mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
Minimum length 2.0 in
5.8 in (147.32 mm) = 058
04 One 3/4-14 NPT plug only
023/4-14 NPT
Proximity Probe HousingAssemblies
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
096 Minimum length 9.6 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
Proximity Probe HousingAssemblies
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
085 Minimum length 8.5 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT
Proximity Probe HousingAssemblies
34 3300 XL 8 mm probe with connectorprotector
selectable hazardous areaapprovals
10 1.0 m (39 in)
066Minimum length 6.6 in
04 One 3/4-14 NPT plug only
02 3/4-14 NPT

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.