Siemens

Master-Modul

SIMATIC DP
Master-Modul IM 180 für 
PROFIBUS-DP,max
12 MBaud
Nennwert (DC):5 V
Stromaufnahme, typ. :250 mA
Prozessortyp:80C165 (40 MHz)
Art des Speichers:2x 128 kbyte
Schnittstellen/Bustyp:Dual-Port-RAM

Vibro-Meter

Proximity Sensor

2 or 4 mm measurement range
−40 to 180 °C operating temperature
0.5, 1.0, 1.5, 2.0 or 5.0 m integral coaxial cable
Versions certified for use in potentially explosive atmospheres
Conforms to API 670 5th edition
8 mV/µm or 2.5 µA/µm (2 mm range)
4 mV/µm or 1.25 µA/µm (4 mm range)
−40 to 180 °C, Ø8.2 mm tip, reverse-mount

Vibro-Meter

Signal Conditioner

Voltage at min. GAP : −1.6 V
Voltage at max. GAP : −17.6 V
Dynamic range : 16 V
Output impedance : 500 Ω
Short-circuit current : 45 mA
Output capacitance : 1 nF
Output inductance : 100 µH
Operating : −35 to +85°C
Storage : −40 to +85°C

General Electric

Emergency Turbine Protection I/O Pack

Input Voltage Range: 85–264 V AC
Output Voltage: 24 V DC
Output Current: 10 A
Efficiency: 88%
Operating Temperature Range: -40°C to +70°C
Storage Temperature Range: -40°C to +85°C
Humidity Range: 5% to 95% non-condensing
Power Consumption: Approximately 25 W

Vibro-Meter

Communication Board

VM600 series
Humidity: 5% to 95% non-condensing
Vibration: 0.15 g²/Hz (5 to 500 Hz)
Shock: 15 g (11 ms half-sine)
Operating Temperature Range: -20°C to +60°C (-4°F to +140°F)
Storage Temperature Range: -40°C to +85°C (-40°F to +185°F)

Vibro-Meter

CPUM modular CPU card

VM600 series
Humidity: 5% to 95% non-condensing
Vibration: 0.15 g²/Hz (5 to 500 Hz)
Shock: 15 g (11 ms half-sine)
Operating Temperature Range: -20°C to +60°C (-4°F to +140°F)
Storage Temperature Range: -40°C to +85°C (-40°F to +185°F)

PROPORTIONAL AMPLIFIER CARD

PROPORTIONAL AMPLIFIER CARD
2.5AMP
12VDC
VP01-B

UniOP

OPERATOR INTERFACE

OPERATOR INTERFACE
TOUCHPANEL
5.7 INCH MONOCHROME LCD
24 VDC
0.6 AMP
RS-232 / RS-485 / RS-422 / PC/PRINTER

Bently Nevada

Process Variable Monitor

Inputs Signal -10 Vdc to +10 Vdc 
Barrier I/O:4-20 mA DC
 Isolated I/O:4-20 mA DC
Voltage Compliance:13.66 V 
Isolation:500 Volts 
Power Consumption: 7.0 Watts, typica
External transducerPower:+24 Vdc. +/- 5% @ 250mA max. Fused

Bently Nevada

Process Variable Monitor

Inputs Signal -10 Vdc to +10 Vdc 
Barrier I/O:4-20 mA DC
 Isolated I/O:4-20 mA DC
Voltage Compliance:13.66 V 
Isolation:500 Volts 
Power Consumption: 7.0 Watts, typica
External transducerPower:+24 Vdc. +/- 5% @ 250mA max. Fused.

General Electric

PROTECTION RELAY

Ambient Humidity Maximum:Up to 95% non condensing
Dimensions:approx: 11.5 in H x 5.5 in W x 8.5 in L
Display Version:Enhanced
Fuse:3.15 A H 250 V
Input Power:110-250VDC 100-240VAC
Manufacturer:GE Multilin
Model Number:369-HI-R-M-0-0-0-E
Phase Current Input:1 A and 5 A secondary

Honeywell

Analog Output Module

Output Type:4-20 mA 
Output Channels:16
Output Temperature Drift:0.005% of Full Scale/°C
Output Readback Accuracy:±4% of Full Scale
Resolution:± 0.05% of Full Scale
Directly Settable Output Current Range:0 mA, 2.9 mA to 21.1 mA
Maximum Resistive Load:800 ohms
Maximum Open Circuit Voltage:22 V

ABB

Bus Connection Module

Auxiliary power supply Powered from host device (5V dc)
Burden ~ 0.4 W Max
Max data transfer rate 1.25 Mbps
Operating temperature range -10...55°C
Storage temperature range -40...70°C

ABB

Power interface board

Application: DCS800 DC Drives
Operating Temperature:0°C to +55°C
Storage Temperature:-25°C to +70°C
Humidity:Up to 95%, non-condensing

General Electric

Reflective Memory interface Module

Memory Size:8 MB, 16 MB, or 32 MB
Data Transfer Rate:Up to 43 MB/s
Node Support:Supports up to 256 nodes
Connectors:
ST-style fiber-optic connectors
Power Requirements:+5 VDC
Storage Temperature:-40°C to +85°C
Operating Temperature:0°C to +60°C

Bently Nevada

Data Acquisition Interface Unit

8 Signal Inputs
Enhanced Parallel Port for 
Connecting to 208-P DAIUs
80 Mb Hard Disk Space
Up to 16 Channels
Real-Time Display Capability
Backwards Compatible with 
Existing ADRE 3 Databases

Extension Cable

Impedance: Typically 50Ω or 75Ω
Length: 45 feet (13.72 meters)
Temperature Range:
Operating: -40°C to +120°C.

Isolated current input module

Input Type:4-20 mA
Input Voltage:24 V DC
Input Range:4-20 mA
Signal Isolation:1500 V to 2500 V
Accuracy:accuracy of ±0.1%
Operating Temperature Range:0°C to 60°C (32°F to 140°F)
Power Supply:24 V DC

ABB

AC-DC/DC-DC Power supply Converter Moudle

Range: 85 V to 264 V AC
Frequency: 50/60 Hz 
Primary DC Output Voltage: 24 V DC
Total Output Power: 160 W
Primary Output Current: 6.7 A
Storage Temperature: -20°C to 85°C
Operating Temperature: 0°C to 60°C

ABB

Synchron Transformer

Rated Power: 5 VA (Volt-Ampere)
Primary Voltage: 110 V (Volts)
Secondary Voltage: 9 V (Volts)
Rated Power Capacity: 5 VA 
Frequency: 50/60 Hz

ABB

Synchron Transformer

Rated Power: 10 MVA
Primary Voltage: 7 kV
Secondary Voltage: 0 kV 
Frequency: 50 Hz or 60 Hz 

Siemens

ABB

Rigi Crowbar Drive PCB

Power Supply:24V
Operating Temperature Range
Typically -20°C to +60°C
Storage Temperature Range
-40°C to +85°C

ABB

Interface Board

24 VDC
Low power design
typically <10 W
Multiple I/O ports for 
interfacing with sensors
actuators, and controllers.
Optimized for high-speed 
communication to minimize latency

ABB

Prog.Logic Controller

Memory Size:642 kB
Memory Type User Data:RAM
Controller Processing Time:0.00008 ms
Analog Inputs:2
Analog Outputs:1
Number of Digital Inputs:6
Number of Digital Outputs:6
Number of Digital Configurable I/Os:0
Input Voltage Type:DC
Rated Voltage (Ur):24 V DC
Supply Voltage:20.4 … 28.8 V DC