TDB MODULE PC BOARD
TDB MODULE PC BOARD
690VAC
FOR CONVERTER MODULE
3-phase AC Voltage: 690 V AC(±10%)
Frequency Tolerance: ±5%
Isolation Voltage: 2000 V AC
Operating Temperature:-25°C to +55°C
DRIVE BOARD
Logic Power Supply: 24 V DC
Analog Inputs:0–10 V, 4–20 mA
Switching Frequency:2–16 kHz
Temperature: -10°C to +50°C
Humidity: ≤85% (non-condensing)
TSE module
Input Channels: 1–4 sensor
Supply Voltage: 24 V DC (±10%)
Current Consumption: ≤100 mA
Ambient Temperature: Operational range 0–55°C
TECHNOLOGICAL BOARD
SIMOVERT MASTERDRIVES
TECHNOLOGICAL BOARD
T100 INCL.
OPERATING INSTRUCTIONS FOR HW
BUT WITHOUT SOFTWARE MODULE
POWER INTERFACE CONTROL BOARD
control electronics Standard incl.
terminals C98043-A7100-L1
Primary Supply (Logic): 24 V DC ±10%
Current Handling (Logic): ≤5 A
Analog signal inputs:±10 V, 4–20 mA
Operating: 0°C to +40°C (full rating).
Extended: Optional derating up to +60°C
Humidity: ≤85% (non-condensing)
Power supply module
SIMOVERT Master drives
Power supply module
PSU1 For devices with
Designs E through H 3 AC
380-460, 660-690V, 50/60 Hz
and 510-620V DC
890-930 V DC
Inverter IGD trigger board
Input Voltage: 24 V DC
Voltage Range: +15 V to -10 V
Current Capacity: 5–10 A
Switching Frequency: Up to 20 kHz
Galvanic Isolation Voltage: ≥2500 V AC
Operating Temperature: -20°C to +55°C
Storage Temperature: -40°C to +85°C
Inverter drive board
Control Voltage: 24 V DC
Signal Voltage: 5 V/3.3 V
Switching Frequency:12–16 kHz
Current Ratings:55–160 kW
Overload Capacity: Typically 150%
Temperature: –10°C to +40°C
Humidity: ≤90% (non-condensing)
Inverter drive board IGD trigger board
Trigger Voltage/Current:+15 V/-10 V
Switching Frequency: Up to 20 kHz
Isolation Voltage: ≥2000 V AC
Logic Supply: +24 V DC (±10%)
Gate Driver Supply: ±15 V DC
Operating Temperature: 0–55°C
DRIVE BOARD
Power Supply (Control Section): 24 V DC (±20%)
DC Link Voltage Handling:500–800 V DC
Motor Compatibility: up to 100s of kW
Switching Frequency: 2–16 kHz
Digital Inputs/Outputs:≥6 DI/DO
Analog Inputs:≥2 × ±10 V, 4–20 mA
Operating Temperature: 0–45°C
POWER ENTRY CONTROL MODULE
Voltage Range: 3-phase AC input
Frequency: 50/60 Hz (±5%)
DC Link voltage:510–720 V DC
Continuous Current (DC Link): Up to 60–80 A
Auxiliary Voltage Supply: 24 V DC
Aambient Temperature: 0–40°C
G120L Inverter Motherboard
Supply Voltage: 24 V DC (±20%)
Power Consumption: ≤15 W
Motor Compatibility: up to 55 kW
Standard Communication:PROFIBUS DP
Operating Temperature: -20°C to +60°C.
Relative Humidity: ≤95% (non-condensing)
OPERATOR INTERFACE
OPERATOR INTERFACE
PANELVIEW STANDARD
KEYPAD & TOUCH
PANELVIEW 550
5.3 INCH DISPLAY
256 X 128 PIXELS
MONOCHROME DISPLAY
REMOTE I/O
RS-232
100-240 VAC INPUT
50/60 HZ
Inverter Power Board
Voltage Range:380–480 V AC
Frequency: 50/60 Hz ±5%
Rated Current:20–200 A
Continuous Power: 10–150 kW
Operating Temperature: -10°C to +50°C (storage up to +70°C)
Digital Output Module
PROCESSOR MODULE
FIELD CONTROL UNIT
NO EXPLOSION PROTECTION
BASIC TYPE
TWO ETHERNET BUS PORTS
LED INDICATORS
S1 SERIES
Digital Output Module
DIGITAL INPUT MODULE
32 CHANNEL
24 VDC
ISOLATED
50 MA
PULSE WIDTH OUTPUT FUNCTION
TIME-PROPORTIONAL OUTPUT FUNCTION
STATUS DISPLAY
NO EXPLOSION PROTECTION
Digital Input Module
Number of input channels:64
Rated input voltage:24 V DC
Input ON voltage:20 to 26.4 V DC
Input OFF voltage :5.0 V DC or less
Input current :2.5 mA±20 % / channel
Maximum allowable input voltage:30.0 V DC
Input response time :8 ms or less
Minimum ON detection time:20 ms
Maximum ON/OFF cycle:25 Hz
Maximum current consumption:500 mA (5 V DC)
ESB Bus Coupler Module
EC402 ESB Bus Coupler Module
5 Standard type with no explosion protection
E Standard type with explosion protection
0 Basic type
1 With ISA Standard G3 option
Operating Voltage:24 V DC
Pulse Input Module
Number of inputchannels:8, isolated channels
Input frequency :0 to 10 kHz
Minimum input pulse width:40 µs
Pull-up resistance:68 kΩ (12 V DC or 24 V DC)
Filter:Filter for eliminating chattering can be set
Data update period:2 ms
Frequency Converter Drive Board
PROFIBUS/MPI or PROFINET
Control Voltage: 24 V DC (±15%)
Output Switching Frequency: 1–16 kHz
Isolation Voltage: ≥2.5 kV AC
Operational Temperature: 0°C to +50°C
Inverter control board
Control Voltage: +24 V DC
Switching Frequency: 5 kHz–15 kHz
Output Pulses: ≥8 PWM
Digital: Start/stop, fault reset
Analog: ±10 V
Operating Temperature: –10°C to +50°C
Inverter control board
Inverter control board
IGD9 for devices 510-620 V DC
1300 A
Logic Supply Voltage: +24 V DC (±10%)
DIP Switches:0–10 V, 4–20 mA
Operating Temperature: 0°C to +40°C
Humidity: ≤95% (non-condensing)
INVERTER DRIVE TRIGGER BOARD
Control Voltage: 24 V DC (±10%)
Isolation Voltage: ≤2.5 kV AC
Output Frequency: ≤20 kHz
Max Output Current: 3–5 A
Signal Logic: 0–24 V DC control signals
Operating Temperature: –10°C to +55°C
Storage Temperature: –40°C to +85°C
Relative Humidity: ≤93% (non-condensing)
Frequency converter trigger driver board
Logic Circuit: 24 V DC
Isolation Voltage: ≥2.5 kV AC
Output Current: Up to 2–3 A
Frequency Range: 1 kHz–20 kHz
Operating Temperature: 0°C to +60°C
Humidity: ≤95% (non-condensing)
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.