ALL MANUFACTURERS


ALL MANUFACTURERS
Please click on the part number or image to view product details.
show:
2601-2625 of 80404
< page << 105 of 3217 >
ABB

Inverter Drive

Power Rating:5.5 kW
Phase:3
Supply Voltage:400 V ac
Current Rating:13.8 A
For Use With:AC Motors
Series:ACS310
Field Bus Communication Type:ModBus
IP Rating:IP20
Output Frequency:0 → 500Hz
STO:No
Drive Type:AC
Mounting Type:Module For Cabinet Building

Frequency Converter

Power Supply: 3-phase 380-480V AC, 50/60 Hz
Output Voltage: Adjustable from 0 to input voltage
Output Frequency Range: 0 to 320 Hz
Rated Power: 22 kW
Current Rating:  47.5 A 

Interface Circuit Board

Input Voltage: 24V DC
Isolation Voltage: Up to 1500V DC
Operating Temperature: -20°C to 70°C

Siemens

Power supply module

Power supply module 
PSU1 For devices with 
Designs E through 
H 3 AC 500-575V, 
50/60 Hz and 675-780V DC

Woodward

Digital Synchronizer Load Control Module

DSLC MASTER 
SYNCHRONIZER AND LOAD CONTROL
MICROPROCESSOR
3PHASE
DIGITAL
IMPORT/EXPORT

Module

Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C

Alarm ALA Board

Input Voltage Range:24 V DC or 110 V AC/DC
Relay Contacts:1 A to 5 A,
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C

ABB

TACHOMETER CARD

Type: Tachometer Card
Series: SADC
Input Type:0-10 V or 4-20 mA output
Input Voltage Range:0 to 10 V DC
Operating Temperature Range:-20°C to +70°C
Storage Temperature Range:-40°C to +85°C

Digital Input Module

Input Voltage Range: 24 V DC
Number of Inputs: 32 discrete inputs
Operating Voltage:  24 V DC
Operating Temperature: -20°C to +60°C 
Storage Temperature: -40°C to +85°C
Humidity Range: Typically 5% to 95% 

DIESEL SBU MODULE

Power Supply: Typically 24V DC
Operating Temperature: Typically -20°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95%, non-condensing

Flexible Control Controller

Open circuit voltage: 24 VDC
Closed circuit current: 5 mA, DC
Frequency range: 0-4 Hz
Tolerance: ± 3.3 % of full scale
Repetitive accuracy: ± 1 % of full scale
Input resistance, current: < 250 Ω
Input resistance, voltage: 10 kΩ ± 10 %
Maximum contact load: 240 VAC, 2 A
Minimum contact load: 5 VDC, 10 mA

Remote Distress Alarm

Input Voltage: 24V DC (nominal)
Power Consumption: Typically 10W
Operating Temperature: -15°C to +55°C
Storage Temperature: -40°C to +70°C
Humidity: 0 to 95% RH, non-condensing

Powermonitor 3000 Master Module

Powermonitor 3000
Master Module with 
3-Phase metering & setpoints & I/O
Data logging
5 Amps, Control Power
120V/240V AC 50/60- Hz or 
125V/250V DC
Revenue metering 
compliance to 1% Accuracy

B&R

Digital input module

I/O module:16 digital inputs 24 VDC in 4 groups
Status indicators:I/O function per channel
Operation:0 to 60°C
Storage:-25 to 70°C
Nominal voltage:24 VDC
Hardware:≤12 ms

Temperature Controller

Switchable displaysk 
Text or bar graph displayk 
8 limit comparatorsk 
4 setpointsk 
2 parameter setsk 
Maths and logic modulek 
Ramp and profile program function

Schneider Electric

Network switch

Concept:Transparent Ready
Port Ethernet:10/100BASE-TX - 8 port(s) copper cable
Supply voltage limits:9.6…32 V DC SELV
Power consumption in W:6 W
Alarm output:1 voltfree contact 1 A
Ambient air temperature for operation:0…60 °C
rated supply voltage:12...24 V

Weight indicator

Load cell supply 5 V alternating current supply
Input signal 0 15 mV
Sensitivity 0.6 μV / d
Unit kg, g, t, lb, N, kN
Linearity error <0.05 ‰ / 10 K
Range stability,TKc<0.04 ‰ / 10 K

Flue Gas Oxygen Analysers

Measuring Range:From 0 to 1 %, 0 to 25 % O2 v/v 
Linearity:±1 % of output span 
Repeatability:±1 % of output span 
Max. Flue Gas Temperature: 800 °C (1472 °F) 
Sample Pressure:±2 psig (± 13.8 kPa)
Display / Keypad:Single-line 4 digit LED; 4 keys
Environment:Ambient Temp.: -20 to 71 °C (-5 to 160 °F) 
Relative Humidity:10 % to 80 %, non-condensing 

Encoder

Power Supply:Typically 5 to 24 VDC
Current Consumption:Typical: 40 mA
Operating Temperature:
-10°C to +70°C (14°F to 158°F)
Storage Temperature:
-20°C to +85°C (-4°F to 185°F)

DEIF

Paralleling & Protection Unit

Input Voltage:110/220 VAC or 24 VDC
Frequency Range:50 Hz or 60 Hz
Operating Temperature:
-20°C to +60°C (-4°F to +140°F)
Storage Temperature:
-40°C to +85°C (-40°F to +185°F)
Humidity:
5–95% RH

Woodward

SYNCHRONIZING UNIT

Input Voltage:110/220 VAC or 24 VDC
Frequency Range:50 Hz or 60 Hz
Frequency: ±10%
Operating Temperature:-10°C to +60°C (14°F to 140°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Humidity:5–95% RH

ABB

Panel Keyboard Operator

Input Voltage Range: 0–30 VDC
Output Voltage Range: 0–30 VDC
Output Current: Up to 2 A per channel
Input Voltage: 24 VDC ±10%
Power Consumption: ≤10 W
Operating Temperature: -40°C to +85°C
Storage Temperature: -55°C to +100°C
Humidity: 5–95% RH

Discrete I/O Module

Input Voltage Range: 0–30 VDC
Output Voltage Range: 0–30 VDC
Output Current: Up to 2 A per channel
Input Voltage: 24 VDC ±10%
Power Consumption: ≤10 W
Operating Temperature: -40°C to +85°C
Storage Temperature: -55°C to +100°C
Humidity: 5–95% RH

Operator Panel

Digital inputs +12 VDC / +24VDC
Relay outputs 230 V AC/DC, 2 A
Analogue inputs 0-10 VDC
Ambient air temperature 0 ... 50 °C

DEIF

CONTROL MODULE

Rated Voltage: 24 VDC ±10%
Power Consumption: <10 W
Range: 0–5 A
Accuracy: ±0.5%
Operating Temperature: -25°C to +70°C
Storage Temperature: -40°C to +85°C
Humidity: 0–95% RH (non-condensing)
Vibration Resistance: 2 G (10–500 Hz)

show: