Contactor
220-230V 50Hz / 230-240V 60Hz
Model Number: A30-30-10
Rated Operational Current (Ie): 30 A
Rated Operational Voltage (Ue): Up to 690 V AC
Control Voltage: 24-230 V AC/DC
Poles: 3 (3-phase)
Mechanical Life: Up to 10 million operations
Electrical Life: Up to 1 million operations
Enclosure Rating: IP20
Frequency converter
ACS510-550 Frequency converter
Model Number: 3X4K7 10028493B
Input Voltage: 3-phase, 380-480 V AC
Output Voltage: 0-480 V AC
Frequency Range: 0-400 Hz
Rated Power: 7.5 kW (10 HP)
Current Rating: 16 A
Enclosure Rating: IP20 (suitable for panel mounting)
Cooling Method: Air-cooled
power supply module
Nom Input Voltage:220 Volts AC
Input Voltage Range:194-264 Volts AC
Max Real Input Power:56 Watts
Max Apparent Input Power:89 VA
Max Xformer Load:140 VA
User Output Current:N/A
Backplane Output Current:8 Amperes (at 5 Volts DC)
Frequency:47-63 Hertz
Main Circuit Interface Board
Manufacturer: ABB
Model: RINT-6512C
Type: Main Circuit Interface Board
Function: Interfaces between control logic and power circuits in drives/inverters.
Voltage Rating: 24V DC
Temperature Range: -20°C to +70°C.
Humidity: Up to 95% (non-condensing).
Driver board
RINT-6421C
68638721C
Supply Voltage:24 V DC (±10%)
Power Consumption:1.5 W
Isolation:500 V AC
Digital valve amplifier
Operating voltage UB 24 VDC
Upper limit value uB(t)max 30 V
Lower limit value uB(t)min 21 V
Current consumption Imax 1.5 A; standby current 270 mA
Fuse IS 4 A time-lag
Digital inputs Signal log 0 = 0 to 5 Vlog 1 = 16 V to U
Range U ±10 V
Input resistance Re > 100 kΩ, > 10 MΩ for input AI2
Resolution 5 mV for range ±10 V
PCB BOARD
RATED VOLTAGE: 0...793 VAC / 0...650 VDC
SUPPLY VOLTAGE: 88....264 VAC / 77...286 VDC
POWER CONSUMPTION: 14 VA
RELAY CONTACTS: 5 AMP 250 VAC
Processor-based VME (VMEbus) single board computer
Up to 512MB PC133 SDRAM
Built-in SVGA support with 4 Mbytes DRAM display cache
Built-in dual 10/100 Mbit Ethernet
IDE drive support
Floppy drive support
Two RS232 serial ports
Dual USB ports
Real-Time clock/calendar
Front panel reset switch
Miniature speaker
Keyboard/Mouse port
Pcb board
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
Pcb board
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
Pcb board
1 PORT CHANNEL
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
PROFIBUS INTERFACE CARD
PROFIBUS INTERFACE CARD
1 PORT CHANNEL
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector,
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 11 mm Probe
3300 XL 11 mm Probe
5/8-18 UNFthread, with armor
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe,
3/8-24 UNFthread, with armor
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 NSv Extension Cable
065 6.5 meters (21.3 feet)
01 With stainless steel armor
withFEP jacket
01 Multiple Approvals
3300 NSv Proximity Probes
3300 NSv Probe
1/4-28 UNF thread,with armor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required
3300 NSv Extension Cable
065 6.5 meters (21.3 feet)
01 With stainless steel armor
withFEP jacket
CN Multiple Approvals
Velomitor Interconnect Cable
Cable Length:
75 feet (22.86 meters)
Temperature Range:
-29°C to 121°C (-20°F to 250°F)
Ordering Information:
Available in 1-foot (0.3-meter)
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
M10 x 1 thread,without armor
20 2.0 meters (6.6 feet)
02 Miniature coaxial ClickLocconnector,
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
M10 x 1 thread,without armor
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector with connectorprotector,
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
3300 NSv Probe
M8X1 thread,without armor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.