Model: 51401072-300
Type: Memory Board
Function: Used in process control systems
System Compatibility: Honeywell TDC 3000 Process Control System
Operating Temperature Range: 0°C to 60°C (32°F to 140°F)
PQMIIT20CA
POWER QUALITY METER
20-60VDC/20-48VAC
50/60HZ
20VA
ONE 4 TO 20 MA ANALOG INPUT
FOUR (4) OUTPUT RELAYS / FOUR (4) SWITCH INPUTS
FOUR (4) ISOLATED ANALOG OUTPUTS SETPOINTS FOR ALARM OR CONTROL
MODBUS COMM 2 REAR RS485 PORTS 1 FRONT RS232 PORT
Model: IS400REPIH2A-AA
Type:Pcb board
Input Voltage: Typically 48V DC,
Operating Temperature: Typically 0°C to 50°C.
Storage Temperature: -20°C to 70°C.
Humidity: Typically 5% to 95% RH
Model: DSQC 501
Part Number: 3HAC3617-1
Type:Backplane Board
Input Voltage: Typically 24V DC
Operating Temperature: Typically 0°C to 50°C.
Storage Temperature: -20°C to 70°C.
Humidity: Up to 95% RH (non-condensing)
Model: DSQC 328
Part Number: 3HAB7229-1
Type:Digital I/O Relay Board
Input Voltage:24V DC
Storage Temperature: -20°C to 70°C.
Input Voltage: Typically 24V DC
Power Consumption: Typically around 15-30W
Current Rating: Typically 1A at 24V DC
Humidity: Up to 95% RH (non-condensing)
Model: DSQC503A
Part Number: 3HAC18159-1
Type: Axis Computer Board
Operating Temperature: Typically 0°C to 50°C.
Storage Temperature: -20°C to 70°C.
Input Voltage: Typically 24V DC
Power Consumption: Typically around 15-30W
Current Rating: Typically 1A at 24V DC
Humidity: Up to 95% RH (non-condensing)
Model: DSQC504
Part Number: 3HAC5689-1/03
Type: CONNECTION BOARD
Operating Temperature: Typically 0°C to 50°C.
Storage Temperature: -20°C to 70°C.
Humidity: Up to 95% RH (non-condensing).
Model: DSQC505
Part Number: 3HAC4296-1
Type: Power Supply Unit
Input Voltage:AC 100-240V (50/60 Hz)
Output Voltage:24V DC
Output Power:Typically 100W or more (depends on load)
Current Rating:Around 4A at 24V DC
Efficiency: High efficiency for industrial use
Parameter:Value
Voltage Rating:24 V DC
Current Rating:≤ 3 A
Signal Type:DeviceNet™ communication + Power supply
Conductors:11 cores (twisted pairs)
Shielding:Double-layer braided copper shield
Impedance:120 Ω
Gas, steam or liquid measurements
Threads and flange connections
Gas tight feedthrough
Easy menu-guided commissioning
-40 to 257°F (-40 to 125°C) process temp
-15/0 up to 10,500psi (-1/0 up to 700bar) measuring range
HistoROM data management
Overload-resistant
Seamless and independent system integration
6ES79720BB500XA0
SIMATIC DP BUS CONNECTOR
FOR PROFIBUS UP TO 12MBIT/S
90DEGREE ANGLE CABLE OUTLET
15.8X72.2X36.4MM
IPCD TECHOLOGY FAST CONNECT
W/PG SOCKET
Operatingtemperature-35°C to +85°C
Storagetemperature-52°C to +100°C
Power Requires +12 to +35 Vdc input atthe transmitter terminal
Frequencyresponse5 Hz to 6,000 Hz +0, 3 dB.
Minimumtarget size 9.5 mm (0.375 in) diameter.
NonHazardous,Zone 2 or Div 2Hazardousarea locationsPower Supply: 28 V
DIN Rail mounted managed Ethernet switch (wall mounting possible)
Metal housing
Up to 10 ports (electrical, optical or SFP cages)
Up to 3 GbE ports (electrical, SFP or Combo ports)
Multimode and Single Mode versions available
Huge variety on optical ports (e.g. SFP cages, SC, ST)
SFP’s in various versions available (MM, SM, single fibre)
Low voltage (18 - 60 VDC) or high voltage (48 - 320 VDC, 90 - 265 VAC) power supply
Redundant power supply possible
Typical power consumption: 12 - 21 W
Operating Temperature Range: -25°C to +65°C
Storage Temperature Range: -40°C to +85°C
Humidity: 0-95%
Input Voltage: 48V DC
Module Capacity: The rack can accommodate up to 15 slot modules
Rack Dimensions: 19 inch rack width, in compliance with industry standards
From the Vibro-Meter ® product line
Power supply unit for VM600 system rack (6U)
High performance
Wide input voltage range
Over-voltage protection
Continuous short-circuit proof
Minimal derating within the operating temperature range
6U height
Compact design
Fully VME compatible
Conforms to EC standards for EMC