Prog.Logic Controller
Memory Size:142 kB
Memory Type User Data:RAM
Controller Processing Time:0.00008 ms
Number of Digital Inputs:8
Number of Digital Outputs:6
Number of Digital Configurable I/Os:0
Input Voltage Type:DC
Rated Voltage (Ur):24 V DC
Supply Voltage:20.4 … 28.8 V DC
2-port Modbus/TCP adapter module
2 x RJ45 connectors
Data rates: 10/100 Mbps
Maximum Nodes: Up to 32 nodes
Power Supply Voltage: 24 V DC
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% (non-condensing)
Control Unit
Power Supply Voltage: 24 V DC ±10%
Power Consumption: Typically 5 W
RAM: 64 MB (typical)
Analog Outputs: 2 channels, 0-10 V or 4-20 mA
Operating Temperature: -20°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% (non-condensing)
EtherNet/IP adapter module
Supports 10 Mbps and 100 Mbps
Maximum Nodes: Up to 64 nodes
Operating Voltage: 24 V DC ± 10%
Power Consumption: 2.5 W (typical)
Operating Temperature: -25°C to +60°C
Storage Temperature: -40°C to +85°C
Humidity: 5% to 95% (non-condensing)
Control Panel 7 TFT touch screen
Operation 0 +50 °C
Storage -20 +70 °C
Memory Size User Data:128 MB
Memory Size User Program:256 MB
Memory Type User Data:Flash Disk
Memory Type User Program:DDR RAM
Power Consumption (@Pcons):16.8 W
Power Supply:24 (18 ... 30) V DC
Product Main Type:CP635
Product Name:Control Panels
PROFIBUS DP adapter module
Baud Rates Supported: 9.6 kbps to 12 Mbps
Communication Connector: 9-pin D-Sub
Operating Voltage: 24 V DC ± 10%
Power Consumption: Typically 2.5 W
Operating Temperature Range: -25°C to +60°C
Storage Temperature Range: -40°C to +85°C
Relative Humidity: 5% to 95%
CANopen interface Module
Operating Voltage: 24 V DC
Interface Type: CAN 2.0A and CAN 2.0B
Standard CAN: Up to 1 Mbps
Processor Module
Memory Size:642 kB
Memory Type User Data:RAM
Number of Digital Inputs:8
Number of Digital Outputs:6
Rated Voltage (Ur):24 V DC
Supply Voltage:20.4 … 28.8 V DC
POWER SUPPLY
1606XLB480E
POWER SUPPLY
1606-XLB SERIES
SINGLE-PHASE
INPUT VOLTAGE - 100-240 V AC
RATED OUTPUT - 480 W
24-28 V DC OUTPUT
XB205-3 managed Layer 2 IE switch
SCALANCE XB205-3
MANAGEABLE LAYER 2
IE-SWITCH 5X10/100
MBITS/S RJ45 PORTS
3X MM FO ST-PORT 1X
CONSOLEPORT DIAGNOSTICS-LED
REDUNDANT POWER SUPPLY
TEMP.-RANGE 0 DGR C UP TO +60 DGR C; DIN RAIL MOUNTINGPROFINET IO-DEVICE
VersaMax CPUE05 Controller
Program Storage:System flash, battery-backed RAM
Power Requirements:5V uses 220mA, 3.3V uses 570mA
Floating :Pointyes
Boolean Execution Speed:0.8 ms/K (typical)
Realtime Clock Accuracy (for timer functions):100ppm (0.01%) or +/- 9sec/day
Time of Day Clock Accuracy:100ppm at full temperature range
Embedded Communications:RS-232, RS-485, Ethernet
Configurable Memory:64K bytes maximum
Ethernet Data Rate:10Mbps (half- or full-duplex)
Ethernet Port:RJ-45, UTP
Number of SRTP Server Connections:8
DC LVDT Assembly
Linear Range Option : 02= 50.8 mm (2.00 in)
Spring Option : 01 = With spring return
24765 dc LVDT Assembly Electrical Scale Factor
0.404 V/mm (10.25 V/in).
24765 dc LVDT Assembly Electrical Linear Range
50.8 mm (2.00 in).
24765 dc LVDT Assembly Electrical -3 dB Frequency
15 Hz.
SPINDLE DRIVE
Input Voltage: 200 V to 400 V
Output Power: 7.5 kW
Output Current:15 A to 30 A
Frequency Range:0 Hz to 300 Hz
Ambient Temperature: 0°C to 40°C
EMC FILTER 3 PHAS
Type: 3-Phase EMC Filter
Rated Voltage: 480 VAC or 400 VAC
Rated Current: 16 A to 29 A
Frequency Range: 50 Hz to 60 Hz
Attenuation:150 kHz to 30 MHz
Operating Temperature Range: -25°C to +85°C
Storage Temperature Range: -40°C to +85°C
CVMI Board
Voltage Input Range:24 VDC or 110/220 VAC
Current Input: 1-10 A
Power Supply: 24 VDC or 48 VDC
Operating Temperature Range: -20°C to +60°C
Storage Temperature Range: -40°C to +85°C
3300 NSv Probe
3300 NSv Probe
1/4-28 UNF thread,without armor
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connectorwith
connector protector, standardcable
00 Not required
3300 XL 8 mm Probe
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
90 9.0 meters (29.5 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Probe
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector with connectorprotector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Probe
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector with connectorprotector
FluidLoc cable
00 Not required
3300 XL 8 mm Probe
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector with connectorprotector
FluidLoc cable
00 Not required
Interconnect Cable
Product Type : Interconnect Cable
16710 - Model: 3-conductor shielded 22 AWG (0.5 mm2)
armored cable with 3-socket plug at one end,
terminal lugs at the other end.
Minimum length of 3.0 ft (0.9 m)
maximum length of 99 ft (30m)
Infineon Technologies IGBT Module
Collector-Emitter Voltage: 1700 V
Continuous Collector Current: 1000 A at 25°C
Gate-Emitter Voltage : ±20 V
Power Dissipation : 6000 W
Junction Temperature : -40°C to +150°C
Case Temperature : Up to 125°C
Contactor
Contactor
TeSys Deca
3P(3NO), AC-3/AC-3e
440V, 95A
110V AC 50/60Hz coil
screw clamp terminals
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.