Digital Isolated Input Module
Series:ControlLogix
Inputs:16 Individually Isolated; SOE
Input Voltage:125 Volts DC Sink-Source
Operating Voltage Range:90-140 Volts DC
Maximum Input Current, Off-State:0.3 milliamps
Power Dissipation (Max):5.5 Watts at 60 degrees Celsius
Module Type:Digital Isolated Input Module Series of Events
Diagnostic Input Module
Series:ControlLogix
Module Type:Diagnostic Input Module
Inputs:8 Diagnostic
Input Voltage:120 Volts AC
Operating Voltage Range:79-132 Volts AC
Input Delay Time:Programmable 9 or 18 milliseconds
Minimum Operating Current:5 milliamperes at 79 Volts AC
Maximum Operating Current:16 milliamperes at 132 Volts AC
Maximum Input Current, Off-State 2.5 milliamperes
Variable speed drive
Range of product:Easy Altivar 610
Product or component type:Variable speed drive
Device short name:ATV610
Variant:Standard version
type of cooling:Forced convection
Supply frequency:50...60 Hz +/-5 %
Network number of phases:3 phases
rated supply voltage:380...460 V - 15...10 %
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:456 Amps, 250kW ND, 200kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:367 Amps, 200kW ND, 160kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:None
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:302 Amps, 160kW ND, 132kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 7
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:260 Amps, 132kW ND, 110kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:400 VAC, 3 PH
Output Current:260 Amps, 132kW ND, 110kW HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
3300 NSv Extension Cable
065 6.5 meters (21.3 feet)
04With stainless steel armor
withFEP jacket, with connectorprotector
3300 XL 8 mm Probe
3300 XL 8 mm Probe
M10 x 1 thread,with armor
05 0.5 meter (1.6 feet)
01Miniature coaxial ClickLocconnector with
connectorprotector, standard cable
3300 NSv Proximity Probes
3300 NSv Probe
M8X1 thread, witharmor
05 0.5 meter (20 in)
01Miniature coaxial ClickLoc
connectorwith connector protector, standardcable
3300 XL 8 mm Probe
3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector with
connectorprotector, standard cable
05 CSA, ATEX, IECEx Approvals
PanelView Plus 6 Operator Terminal
Manufacturer:Rockwell Automation
Product Family:PanelView Plus 6 Operator Terminal
Memory:512 MB Flash/ 512 MB RAM
Compatible Hardware:PanelView Plus 6 700-1500
Status indicators:Red and Green LED
Interfaces:Ethernet port, serial port, two USB ports
CompactFlash card slot
Marine Certified:Yes
Operating Temperature:0-55 Degree Celsius
Power input:24VDC
Power Dissipation:70 Watts
Digital Output IOTA Redundant
Extensive internal diagnostics to ensure dataintegrity
Optional redundancy
Electronic Overcurrent protection
Configurable Safe-state (FAILOPT)
Latched, pulsed or pulse-width modulated output
Digital Input IOTA Redundant
Extensive internal diagnostics for data integrity
NO Open wire detection
Optional redundancy
Internal or external field power selection
Supplies Non-incendive field power
Direct / Reverse Input Indication
Galvanic isolation
Analog Output IOTA Redundant
Extensive self-diagnostics
Optional redundancy
Supplies non-incendive field power
Open-wire Bad PV Detection
Non-incendive Power
Velomitor CT Transducer
07 Plate Stud 3/8-in 24 to 3/8-in 24
00 MIL-C-5015 connection interface
00 No Approvals
3300 NSv Proximity Probes
330902 3300 NSv Probe
1/4-28 UNF thread,with armor
Minimum unthreaded length: 0.0 in
Minimum case length: 1.0 in
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
05 Multiple Approvals
3300 NSv Proximity Probes
330902 3300 NSv Probe
1/4-28 UNF thread,with armor
Minimum unthreaded length: 0.0 in
Minimum case length: 4.0 in
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
05 Multiple Approvals

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.