PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type:
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:186 Amps, 150HP ND, 125HP HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:156 Amps, 125HP ND, 100HP HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:156 Amps, 125HP ND, 100HP HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered,
CM jumper installed (preferred)
Dynamic Braking:DB Transistor
PowerFlex 753 AC Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:125 Amps, 100HP ND, 75HP HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
HIM Blank (No HIM)
PowerFlex 753 AC Packaged Drive
Bulletin Number:PowerFlex 753 AC Drive
with Embedded I/O
Corrosive Gas Protection and Cooling Type
Standard Protection, Forced Air
Voltage Class:480 VAC, 3 PH
Output Current:125 Amps, 100HP ND, 75HP HD
Enclosure Type:Open Type
Input Type:AC Input with Precharge, no DC Terminals
Frame Size:Frame 6
EMC Filtering Options:Filtered
CM jumper installed (preferred)
Dynamic Braking:None
HIM Blank (No HIM)
PowerFlex 753 AC Packaged Drive
Manufacturer:Rockwell Automation
Brand:Allen-Bradley
Part Number/Catalog No.:20F1ANC477JN0NNNNN
Series:PowerFlex 753
Frames:6...8
Enclosure Type:AC Input w/Precharge, no DC Terminals
Frames:2 2...7
Enclosure Type 2:IP20/IP00, NEMA/UL Type Open
Voltage:400V AC/540V DC
Filtering:Yes
Default CM Cap Connection:Jumper Installed
CPU module
SIMATIC S7-200 SMART
CPU SR20, CPU
AC/DC/relay
onboard I/O: 12DI 24 V DC; 8 DQ relay 2A
power supply: AC 85 - 264 V AC at 47-63 Hz
77 to 138 V DC
program/data memory 20 KB
DC power supply input module
Brand:GE Fanuc
Series:Versamax
Part Number:IC200PWR001
Product Type:DC Power Supply
Input Voltage:24 Volts DC
Output Voltage:5 Volts DC and 3.3 Volts DC
Input Power:11 Watts
Holdup Time:10 Milliseconds
Total Output:1.5 A maximum
3.3V Output Current:0.25 A maximum
SMART DIGITAL OUTPUT MODULE
SMART DIGITAL OUTPUT MODULE
SIMATIC S7-200
8 DIGITAL OUTPUTS
2 AMP RELAY
Inverter Drive
SINAMICS V20
380-480 V 3AC -15%/+10% 47-6
Rated power 0.75 kW with 150% overload for 60 sec
unfiltered I/O interface: 4 DI, 2 DQ, 2 AI, 1 AO
Fieldbus: USS/Modbus
RTU with built-in BOP Degree of protectionIP20/UL
open Size: Size A 90x150x146
PULSE TRANFORMER
Isolation Voltage: Typically 2–4 kV
Primary/Secondary Voltage: 5–24 V AC/DC input
Operating Temperature: -40°C to +85°C
Certifications: Complies with IEC/EN
Turns Ratio: 1:1 or custom ratios
Impedance:50–100 Ω
Single Board Computer
Network: Dual Gigabit Ethernet ports.
USB: USB 2.0/3.0 ports for peripheral connectivity.
Serial: RS-232/422/485 interfaces.
Graphics: VGA, DVI, or DisplayPort for display output
Operating Temperature: -40°C to +85°C (ruggedized variants).
Certifications: MIL-STD-810 (shock/vibration), CE, RoHS.
Power Input: 5V or 12V DC
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.8 in
20 2.0 meters (6.6 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 5.5 in
20 2.0 meters (6.6 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.5 in
20 2.0 meters (6.6 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
Binary output module
24 binary outputs with enclosed relays (NO contacts)
Current carrying capacity of the relays: max. 1 A
Channel-by-channel isolation of the outputs
Module is capable of redundant operation
Monitoring of the module
Counter for switching cycles (channel by channel)
Analog output module
16 analog outputs, output signal 0/4 ... 20 mA,
channel-by-channel configuration
Load: max. 700 Ohm
Monitoring of loads
Channel-by-channel isolation of outputs
Module is capable of redundant operation
Digital communication with field devices according to
HART protocol (Version 5.0 / 5.1)
Monitoring of modules
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Binary input module
32 binary inputs divided into two groups each with 16 inputs
Process current circuits in accordance
with EN 50020 with type of protection EEx ib IIC
Combined installation possible with
"Non-Ex-modules" in one module sub-rack
Signal recording with 1 ms time resolution
Monitoring of module
Central galvanic separation of system inputs
Group-set filter time
Module is capable of redundancy
Coupling Unit
Data Rate: Up to 12 Mbps
Isolation:1500 V AC
Power Supply: 24 V DC (±10%)
Power Consumption: Typically 5–10 W
Fieldbus Port: 9-pin D-sub or M12 for PROFIBUS
Operating Temperature:
-25°C to +70°C (-13°F to +158°F)
Humidity: 5–95% noncondensing
ControlLogix Jumper Bars
BAR JUMPER
CONTROLLOGIX
FOR 36 PIN TERMINAL WIRING BLOCKS
25 PER PACKAGE

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.