Proximity Probe
Proximitor (Demodulator): 3300 XL NSv
Measurement Range: 0 to 40 mils (0 to 1.0 mm)
Sensitivity: 200 mV/mil (7.87 V/mm) ±5%
Frequency Response: 0 to 10 kHz
Gap Voltage (Vgap): -10 V DC
Linearity: ±1% of full scale
Power Supply: -18 to -26 V DC
Output Signal: -2 to -18 V DC
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 0.0 in
Minimum case length: 2.0 in
50 5.0 meters (16.4 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Power Supply Module
Input Voltage:230V AC
Range: -15% to +10% of nominal
Frequency: 50/60Hz ±5%
Output Voltages:+24V DC (±1%)
Current Ratings:24V DC
Efficiency: >88% at full load
Ripple: <1% of nominal output voltage
S+ Infi-net to Computer Interface Module
Processor: 32-bit RISC processor
Memory:8MB RAM
Power Supply: 24V DC ±10%
Power Consumption: <15W
Operating Voltage Range: 18-30V DC
Screw terminals for power
BNC or ST-type fiber for Infi-net
DB9 or DB25 for serial
RJ45 for Ethernet (if equipped)
Controller Module
CPU: 32-bit RISC processor
Clock Speed: 100-200 MHz
RAM: 32-64 MB
Flash Memory: 16-32 MB
Voltage: 24V DC
Power Consumption: 8-15W
Isolation: 1500V AC (input-to-output)
3300 XL Proximitor Sensor
3300 XL Proximitor Sensor
11 1.0 meter (3.3 feet) system length
51 5.0 meters (16.4 feet) system
91 9.0 meters (29.5 feet) system length
05 CSA, ATEX, IECEx Approvals
3300 XL Proximitor Sensor
12 1.0 meter (3.3 feet) system length
52 5.0 meters (16.4 feet) system length
92 9.0 meters (29.5 feet) system length
05 CSA, ATEX, IECEx Approvals
Power Supply Module
Input: 3x 380 to 480 VAC ±10%
Output voltage adjustable via X2X Link
Status information readable via X2X Link
Chopper output for connecting an external braking resistor
3-phase wide range input
Closed metal housing
POWER CARD
Operating Voltage Range:12V to 24V DC
Power Output Capacity:Up to 500W
Communication Interface:RS-485, CANopen
Temperature Range:-20°C to +60°C
Vibration Transmitter
0 5 0-5 mils pp (0-125 μm pp)
0 1 35 mm DIN rail clips
0 5 CSA Division 2, ATEX Zone 0,
ATEXZone 2 and includes ABS maritimeapproval
Power : Requires +12 to +35 Vdc
input at the transmitter terminal.
Maximum Loop Resistance :
1,000 Ω including cable at 35 Vdc.
Current Limiting : 23 mA typical.

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.