Power board
voltage measurement
CM C98043-A7117-L1
Input Power AC:3‑phase (50‑60 Hz)
DClink Output:400‒610 VDC
Max SCR trigger freq:5kHz
Ambient working:-25°C-+ 55°C
Firing pulse transformer
Firing pulse transformer
up to 1000 A DCM
Primary Voltage Range:5–15V DC Pulse
Secondary Output Voltage:20Vpk
Trigger Current Transfer:≥150mA gate trigger output
Signal Rise Time:<0.1μs (typical)
Isolation Voltage:≥4kV AC RMS
Technology module
SIMADYN D
Technology module
T400 for 6SE70/71 and SRT400 32 Bit/32MHz
8BE, 2BA, 4BE/BA 5AE, 2 AO
2 pulse encoder inputs 2SER
INTERFACE+1SSI-encoder or 1SER
INTERFACE+2SSI-encoder Configurable
with D7-SYS 1MB Flash, 2MB RAM
32KB EEPROM
DC Speed Control Power Supply Board
Input Voltage:110–230 V AC
Rated Power:Max ~10 W total load
DC Outputs:±15V (±1%)
Control Loop:+24V DC (±5%)
Max Current:+15V: 700 mA†
Voltage Ripple:50 mVpp (20 MHz BW)
Frequency Stability: 50/60 Hz (±3%)
CONTROL BOARD
CONTROL BOARD
CPU BOARD
Supply Voltage: 24 V DC (±15%)
Supply Voltage: 24 V DC (±15%)
Signal Inputs: 16 mA
Signal Outputs: 250 mA
Embedded Processor: 150 MHz
ELECTRONIC CONTROL BOARD
ELECTRONIC CONTROL BOARD
ADVANCED
DC SPEED
Control electronics
Advanced painted
incl. terminals 32 MB
C98043-A7100-L204
3300 NSv Proximity Probes
330908 3300 NSv Probe
3/8-24 UNF thread,without armor
Minimum unthreaded length: 3.9 in
Minimum case length: 7.1 in
05 0.5 meter (20 in)
01Miniature coaxial ClickLoc
connectorwith connector protector, standardcable
00 Not required
Accelerometers
01 ¼-28 to M6 x 1.00 Stainless Steel
00 100 mV/g ± 20% (10.2 mV/m/s^2±20%)
00 No Approvals
Mounting Thread 1/4-28 Female
Mounting Torque(Maximum)2 to 5 ft-lb
Sensing Element Ceramic
Sensing Geometry Shear
Housing Material Stainless Steel
Sealing Welded Hermetic
Electrical Connector 2-Pin Mil-C-5015
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Minimum unthreaded length: 1.0 in
Maximum case length: 2.7 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 XL 8 mm Reverse Mount Probes
330105-02-12-CC-DD-EE3/8-24 UNF threads
05 0.5 meter (1.6 feet)
02 Miniature ClickLoc coaxialconnector
3300 XL 8 mm Proximity Probes
330101 3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
Maximum case length: 2.4 in
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
330905 3300 NSv Probe
M10X1 thread,without armor
Minimum length: 18 mm
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector
standard cable
05 Multiple Approvals
Digital Input Module
Type: Digital Input Module
Channels: 40 isolated input channels
Input Voltage: Nominal 24 VDC (range: 18–32 VDC)
Input Current: 6 mA per channel typical
Input Impedance: Approx. 4 kΩ
Logic Thresholds:
Logic '1': ≥15 V
Logic '0': ≤5 V
Trusted I/O and Communication Module
SHIELD FOR I/O AND
COMMUNICATION MODULE 1SLOT
Trusted Shield Single Slot Width
Input Voltage:24V DC
Power Consumption: 8W
Digital Inputs: 16–32 channels
Remote Expansion Cable
Full Trusted Controller Capability
100-240 Vac Input
Portable wheeled flight case
Simulation of 60 Field Signals
Pre-wired Dual Ethernet (point to point and hub)
Serial Comms wired to terminals
Configured for Companion Slot DI, AI and DO Modules
Trusted I/O SmartSlot Cable
Model Number: TC-501-02-6M5
Type: I/O SmartSlot Cable
Configuration: Typically used for internal connections
Channels: Supports 40 channels
Termination: Connects Trusted® I/O modules
to FTAs or VFTAs
Panel Mount Operator Advisor Panel (OPADP)
Communication Protocol:Modbus RTU over RS‑485
Display:128 × 64 pixel LCD
Keypad:5-button navigation
LED Status Bar:Yes (visual feedback)
Power Supply:24 V DC
Operating Temp:–20 °C to +70 °C
Storage Temp:–40 °C to +85 °C
Humidity:0–95 % RH, non-condensing
Digital Input 24V IOTA Redundant
Galvanic isolation
Open wire detectio
Optional redundancy
Direct / Reverse Input Indication
Supplies Non-incendive field power
Internal or external field power selection
Extensive internal diagnostics for data integrity
HART Analog Output Module
Input Voltage:100–240 VAC (universal)
Output Voltage:24 VDC (adjustable up to ~27 V)
Output Current:20 A continuous
Protections:Overcurrent, overvoltage, short-circuit
Operating Temperature Range:–25 °C to +70 °C
Safety Manager System Module
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Electronic Earth Leakage Detector
Supply voltage: 24 V DC
Reset input voltage: 18 - 70 V DC
Reset input current: 1.1 mA at 24 V DC
Earth fault threshold: 5.5 mA (± 1 mA)
Max. earth current: 25 - 32 mA
Max. output current: 2 A
Isolation 1500 V DC / 1000 V AC
Initial contact resistance: 30 mW
Operating temperature: -5°C-+50°C (23°F-+122°F)
Max. output voltage: 36 V DC / 30 V AC
DESK OPERATOR ENTRY PANEL
Power Supply:12–24 V DC
Current Consumption:250 mA @ 24 V DC
Connectivity:Serial (RS‑232);
Mounting:Desk or panel mount with screw terminals
Enclosure Type:Indoor use; IP20 equivalent
Operating Temp:0 °C to +50 °C
Storage Temp:–40 °C to +85 °C
Humidity Limits:Up to 90–95% RH, non-condensing
FTA interconnection cable
Direct connection between two
FS-CP series process controllers
20meters long
Shielded twisted pair design
Easy to install and use
Hot-pluggable
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.