330104 3300 XL 8 mm Probe,
M10 x 1 thread,with armor
Minimum unthreaded length: 140 mm
Minimum case length: 190 mm
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
00 Not required
Discrete Internal Barrier I/OModule
with InternalTerminations
16-channel digital I/O module
Intrinsically safe (IS) barriers integrated
24V DC logic
Redundant configuration possible
LED status indicators
Operatingtemperature-35°C to +85°C
Storagetemperature-52°C to +100°C
Power Requires +12 to +35 Vdc input atthe transmitter terminal
Frequencyresponse5 Hz to 6,000 Hz +0, 3 dB.
Minimumtarget size 9.5 mm (0.375 in) diameter.
NonHazardous,Zone 2 or Div 2Hazardousarea locationsPower Supply: 28 V
Supply Voltage: 24V DC (±10%)
Power Consumption: <10W (typical)
Voltage: ±10V, 0–5V
Current: 4–20 mA
Excitation Voltage: 24V DC
Output Type: Analog (4–20 mA)
Accuracy: ±0.1% FS
Resolution: 16-bit or higher
Bandwidth: DC to 20 kHz
330105-02-12-10-02-05
DISCONTINUED BY MANUFACTURER
PROXIMITY PROBE
3300 XL 8 MM
5.0 INCH OVERALL CASE LENGTH
1.0 M (3.3 FT) TOTAL LENGTH
3/8-24 UNF THREAD
WITH ARMOR
Voltage Rating: Typically 300V AC/DC
Impedance: 50Ω or 100Ω for coaxial cables
Insulation: High-temperature thermoplastic
Temperature Range:
Operating: -40°C to +85°C (-40°F to +185°F).
Storage: -50°C to +105°C.
Systems: Designed for Bently Nevada 3500 Series
02 M8 x 1
01 CSA/US/C
Sensitivity3.94mV/mm/s (100 mV/in/s)±5%.
TemperatureSensitivity-14% to +7.5%
Velocity Range 1270 mm/s (50 in/s) peak.
TransverseSensitivityLess than 5% of sensitivity
3-conductor shielded 22 AWG(0.5 mm2)
armored cable with3-socket plug at one end
terminal lugs at the other end.
Minimum length of 3.0 ft (0.9 m)
maximum length of 99 ft (30 m)
330104-06-06-90-02-05
DISCONTINUED BY MANUFACTURER
PROXIMITY PROBE
3300 XL 8 MM
5.0 INCH OVERALL CASE LENGTH
1.0 M (3.3 FT) TOTAL LENGTH
3/8-24 UNF THREAD
WITH ARMOR
3300 NSv Probe
3/8-24 UNF thread
withoutarmor
5.0 metres (16.4 feet)
CN Multiple Approvals
Maximum case length: 9.9 in
Minimum case length: 0.8 in
Example: 2 4 = 2.4 in
085 8.50 metres (335 inches)
00 Without armor
Frequency Response: 0 Hz (DC) to 10 kHz
Noncontacting
Gap-to-Voltage Transducer Systems
Measures Static and Dynamic Distances
0 2 M8 X 1 integral stud
0 5Multiple approvals (CSA, ATEX, IECEx,)
Sensitivity 2.5 mV/m/s2 (25 mV/g) ±5%
AmplitudeLinearity ±1% to 735 m/s2 (75 g) peak
FrequencyResponse10 Hz to 15 kHz
TransverseSensitivity Less than 5% of axial.
MountedResonantFrequencyGreater than 30 kHz
Amplitude ofResonantPeak20 dB maximum