Headers & Wire Housings
NANO-FIT TPA V0 BLK 3 CKT
Product:Accessories
Number of Positions:3 Position
Pitch:2.5 mm (0.098 in)
Tradename:Nano-Fit
Minimum Operating Temperature:- 40 C
Maximum Operating Temperature:+ 115 C
Product:Switching Supplies
Input Type:1-Phase / Single Phase
Output Power: 240 W
Number of Outputs: 1 Output
Output Voltage-Channel 1:24 V
Output Current-Channel 1:10 A
Isolation Voltage:3 kVAC
Maximum Operating Temperature: + 70 C
Minimum Operating Temperature:- 40 C
Switching Capacity: 32 Gbps
Forwarding Rate: 23.8 Mpps
MAC Address Table: 8K entries
Jumbo Frame Support: Yes (up to 9KB)
VLAN: Supports up to 256 VLANs
Power Supply Voltage: 12-48 VDC
Power Consumption: 20 W (typical)
Operating Temperature:-40°C to +75°C (-40°F to +167°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Output Type: Digital (On/Off)
Nominal Output Voltage: 24 VDC
Output Channels: 16 discrete output channels
Total maximum current per module: 8 A
Power Supply: 24 VDC (nominal)
Power Consumption: 5 W typical
Signal Logic: TTL compatible
Output Type: Digital (On/Off)
Nominal Output Voltage: 24 VDC
Output Channels: 16 discrete output channels
Power Supply: 24 VDC (nominal)
Power Consumption: 5 W typical
Signal Logic: TTL compatible
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Nominal Output Voltage: 4-20 mA
Voltage Range: 0 to 20 mA
Output Resolution: 16-bit digital-to-analog conversion
Power Supply: 24 VDC
Output Load Resistance: 0 to 500 Ω
Power Consumption: 5 W typical
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Nominal Output Voltage: 4-20 mA
Voltage Range: 0 to 20 mA
Output Resolution: 16-bit digital-to-analog conversion
Power Supply: 24 VDC
Output Load Resistance: 0 to 500 Ω
Power Consumption: 5 W typical
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: 3 W typical
Input Voltage: 24 VDC
Input Current: 10 mA
perating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically 3 W
Input Voltage: 24 VDC
Input Current: 10 mA
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically 5 W
Analog voltage: ±10 VDC
Current: 4–20 mA
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically 5 W
Input Types:Voltage: ±10 VDC
Input Types Current: 4–20 mA
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Signal Types Supported Voltage: ±10 VDC
Signal Types Supported Current: 4–20 mA
Accuracy: ±0.1% of full scale
Sampling Rate: 500 Hz per channel
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically 5 W
Input Channels: 16 Analog input channels
Voltage :0–10 VDC, ±10 VDC
Current: 4–20 mA
Sampling Rate: 500 Hz
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically 5 W
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Input Channels: 16 Analog input channels
Voltage :0–10 VDC, ±10 VDC
Current: 4–20 mA
Sampling Rate: 500 Hz
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically 5 W
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Input Channels: 12 Analog input channels
Signal Type:Voltage 0-10 VDC
Current :4-20 mA
Accuracy: ±0.1% of full scale
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically <6 W
Nominal Operating Voltage: 125 VDC
Voltage Range: 85–250 VDC
Power Consumption: Typically <10W
Range: 0–100,000 RPM
Accuracy: ±0.1% of full scale
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)
Function: ESB Bus optical transport function
Connection method: Star type connection
Chain type connection
Available for both star and chain type connection.
Number of connecting stage: Maximum two
Transmission distance: Maximum 5 km (total two stages)
In case of Vnet/IP system with the R1.03 or later,
the total distance of two stagesis maximum 10 km.
Current consumption: 0.5 A
Number of output channels 8 channels, module isolation
Rated output range 4 to 20 mA
Maximum range of guaranteed precision 1.25 to 23 mA
Output range 1.25 to 23 mA
Allowable load resistance @ rated range 230 to 600 Ω
Accuracy ±48 µA
Data update frequency 40 ms
Temperature drift ±16 µA/10 ºC
Withstand voltage 1.5 kV AC between output signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
External power supply 24 V DC +20 %/–10 %
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 2 A/output line
Minimum load current 100 mA
Load resistance range 12 to 240 Ω)
Maximum lamp load (*1) 1 A/output line
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of inputs 16-channel, module isolation
Input current 6 mA ± 20 %
Contact rating 24 V DC +20 % / -10 %
External power supply 24 V DC +20 % / -10 %
Input response time 40 ms maximum
Withstand voltage (*1) (*2) 2 kV AC between input signal and system for 1 minute, 16-input line collectivelyconnected
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute
Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum
Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
Output format Current source
Maximum load current 2 A/output line (8 A in total output lines) (*4)
Minimum load current 100 mA
Load resistance range 12 to 240 Ω (*6)
Analog Inputs:0-10V or 4-20m
Digital Outputs:24V DC
Analog Outputs: 0-10V or 4-20mA
Power Supply:24V DC
Digital Inputs: Typically 8 or 16 digital inputs
Operation method:Unipolar constant current drive
Applied Motor:2-phase stepper motor
Resolution:Intelligent type
Power supply:24-35VDC
Max. Run Current:2A/Phase
Max. Current Consumption:3A
Number Of Axes:1-axis
Environment_Ambient temperature:0 to 50℃, storage: -10 to 60℃
Environment_Ambient humidity:35 to 85% RH, storage: 35 to 85% RH
Dynalco Part No.: LMD-120D
Description: Current Loop-Powered Digital Indicator
Input Signal: 4–20 mA or 10–50 mA, jumper-selectable
Loop Burden: 2 volts maximum, i.e. 100 Ohms at 20 mA
Display: 3½ digits standard;
4½ digits with fixed zero at right-most digit.
Selectable decimal point.
Span and zero adjust:
25-turn potentiometers permit span adjustment from
100 up to 2000 units, and zero adjustment
from – 1000 up to +1000 units
Accuracy: 0.1% linearity,
0.5% stability over the environmental range
Voltage Rating:400V AC
Current Rating:45A at 400V
Frequency Range:0-500 Hz
Input Power: 3-phase 400V AC
Control Inputs/Outputs:0-10V or 4-20mA
Operating temperature range: Typically -10°C to +50°C
Storage temperature range: -40°C to +70°C
User memory:10 megabytes
Safety memory:5 megabytes
Digital I/O / Analog I/O:128,000 / 4000 max
Ethernet performance:10/100/1000 megabits per second
Current draw at 1.2 Volts DC:5.0 milli Amps
Current draw at 5.1 Volts DC:1.2 Amps
Armored and Unarmored Options
Multiple Connector Options
Complete Interchangeability of Units and Cabling
Compact Form Factor
-18 to -24VDC VT
Wide Temperature Range: -55°C to 100°C
11mm Probe Diameter
Aluminum body with 304stainless steel sleeve
28 3300 XL 8mm probe,
selectablehazardous area approvals
05 0.5 m (20 in)
00 Without fittings
023/4-14 NPT
3300 XL 8 mm Probe
3/8-24 UNFthread
without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 11 mm Probe
5/8-18 UNF-2A, without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C
Storage Temperature:-40°C to +85°C
Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C
Storage Temperature:-40°C to +85°C
Input Voltage:24V DC
Current Consumption:Typically 100-200 mA
Fieldbus Power:24V DC
Operating Temperature:Typically -10°C to +60°C
Storage Temperature:-40°C to +85°C
Communication profile CiA 301
Number of installed NFLC121 modules 4 max. for FCN-500
Number of slave devices 126 slave devices per
CANopen Communication Module
Node Bootup
SYNC producer
Heartbeat Consumer/Producer
Number of output channels 16
Rated applied voltage 24 to 125 V DC
100 to 240 V AC, 50/60 Hz
Output response time 12 ms or less
Maximum current consumption 780 mA (5 V DC)
External connection Pressure clamp terminal
Number of input channels 8, isolated channels
Input signal (*1) Contact ON/OFF, voltage pulse
Input frequency 0.1 Hz to 10 kHz
Frequency accuracy 0.1% of reading
Minimum input pulse width 40 μs
Shunt resistance Select from OFF/1000 Ω
Pull-up resistance 68 kΩ (12 V DC or 24 V DC)
Data refresh cycle 10ms
Maximum current consumption 300 mA (5 V DC), 400 mA (24 V DC)
100 to 120 V AC
Duplex configuration: Possible
Hot-Swap: Possible
Rated output: +5.1 V DC, 7.8 A
Analog field power supply: Input: 24 V DC ±10 %, 4 A,
Duplexed (matching-diode)• LED: SYS
(5 V system power output ON)
FLD (24 V field power supply ON)
Checking terminals: +5 V, +24 V
Transmission method Serial communication
Baud rate 128 Mbps
Transmission distance Max. 8 m per line
Extension units Max. 2 units
Duplex configuration Possible
Supplyvoltage 5 V DC±5%
Currentdissipation Max. 500 mA
Rated input voltage:220 to 240 V AC
Input voltage range:170 to 264 V AC (rms)
Input frequency:47 to 66 Hz (Rating: 50/60 Hz)
Input current: Max. 0.7 A
Fuse rating:3.15 A
Leak current Max. :1 mA
Withstanding voltage:3000 V AC for 1 minute
Insulation resistance:50 MΩ at 500 V DC
Input signal 4 to 20 mA
Allowable input current 24 mA
Accuracy ±0.1% of full scale
Overcurrent protection Provided
Data refresh cycle 10 ms
Input step response time 100 ms
Temperature drift Max. ±0.01%/°C
Operation -40 to +70 °C
Transportation/storage -40 to +85 °C
Dust 0.3 mg/m3 or less
Protection class IP20
Altitude 3000 m or less
Electric field 3 V/m or less (26 MHz to 1 GH
Magnetic field 30 A/m (AC) or less, 400 A/m (DC) or less
01 110 to 220 Vac @ 50 to 60 Hz (externalsupply)
00 No display
03 Fiberglass NEMA 4X/IP66 WP housingwith window in door
00 None
00 None
EQUIPMENT MONITOR
GENERAL PURPOSE
1900/65A SERIES
Product Type: PAMC Acoustic Monitor (Processor)
Software: ControlST V04.03.18C
Relative humidity: 5% to 95%, no-condensing
Power Requirements +32 V dc to 18 V dc
Microprocessor: Freescale Power PC (Power QUICC II PRO 667 MHz)
Memory: 256 MB DDR SDRAMs
Freescale™ QorIQ P4080 –
8-core CPU @ 1.5GHz
Serial Rapid IO, PCIe
and 1/10GbE fabrics
Fast dual-channel memory
(up to 8 GB RAM with ECC)
Useable in managed (with MCH)
and unmanaged (without MCH) systems
24V DC for logic power
230V to 690V AC
Approximately 10-20W
0 Hz to 200 Hz
Standard range: -10°C to +50°C
Storage Temperature:-40°C to +85°C
5% to 95% RH, non-condensing
FLOWMETER MASSFLO
MASS 3000
115/230VAC/ENCLO-IP00
Gas Flow: 0.01 to 1000 kg/h
Liquid Flow: 0.1 to 1000 kg/h
Typical Accuracy: accuracy of ±0.5% of readin
Standard Temperature Range: -40°C to +150°C
Operating Pressure:0 to 100 bar
Analog Output:4-20 mA
Voltage Range: 24 V DC
R/I TRANSMITTER 24VDC 0-20MA
Input for Pt100, Ni100 or Ohm
Sensor cable compensation
Linearised analogue output
24 VDC or universally supplied
Individual 0 and 100% adjustment
DIN rail mounting on a standard 11-pole relay socket
Configuration: Non-isolated thermocouple input
Linear range: 4 to 20 mAdc
Current Output limits: <2 to >40 mA (open TC)
Compliance (supply-voltage): 8 to 50 Vdc
Reverse polarity protection: 350 V peak
Maximum loop resistance: (Supply Voltage - 8V)/20 mA
AC Power:100-240 V AC.
Max. Monitor Connections: 4 indoor monitors
Power Consumption:20-40W
Operating Temperature:
Typically, 0°C to 40°C (32°F to 104°F).
Humidity:
Typically up to 80% relative humidity
Range of Product:Altivar 312
Motor power kW:0.37 kW
Maximum Horse Power Rating:0.5 hp
Supply frequency:50...60 Hz - 5...5 %
EMC filter:Integrated
Apparent power:1 kVA
Maximum transient current:5 A 60 s
Power dissipation in W:41 W at nominal load
Speed range:1…50
Processor Model: PowerPC 600 series
Clock Speed: 200 MHz and 500 MHz
Memory Capacity: 64 MB to 1 GB
Memory Interface: 32-bit or 64-bit
Ethernet: 10/100/1000 Mbp
Input Voltage: 5 V to 12 V DC
In operation: +5 to +45 °C
Storage and transport: –25 to +60 °C
75 % year-round average
Input voltage 230 V AC or 115 V AC, 50 Hz or 60 Hz
Power consumption max. 185 VA
Sample gas pressure pabs = 70 to 105 kPa (0.7 to 1.05 bar)
Sample gas inlet temperature +10 to +50°C
Frequency coverage:136–174MHz
Number of channels:Max. 128 Ch/ 8 zones
Channel spacing:12.5/25kHz
Type of emission:16K0F3E, 11K0F3E
Current drain:10.0A
Max. audio:0.7A
Stand-by:250mA
Part Number/Catalog No.:2080-IF2
Product Type:Analog Plug-in Module
Module Type:Analog
Number of Single-Ended Inputs:2
Data Range:0-65535
Repeatability:+/- 0.1%
Update Time:180ms per Enabled Channel
Operating Altitude:2000m
Part Number/Catalog No.:2080-IF4
Product Type:Analog Plug-in Module
Module Type:Analog
Number of Single-Ended Inputs:4
Analog Normal Operating Voltage Range:0-10V DC
Analog Normal Operating Current Range:0-20mA
Data Range:0-65535
Repeatability:+/- 0.1%
Part Number/Catalog No.:2080-OF2
Product Type:Analog Plug-in Module
Number of Single Ended Outputs:2
Analog Normal Operating Voltage Range:10V DC
Repeatability:+/- 0.1%
Series:Micro870
Part Number:2080-L70E-24QBB
Product Type:Programmable Controller
CONTROLLER
PROGRAMMABLE
MICRO 820
12 INPUTS
24 VOLT DC
8 OUTPUTS: 7 RELAY AND 1 ANALOG
0 - 10 VOLT DC
4 ANALOG INPUTS
0 - 10 VOLT DC INPUT
SHARED WITH DC INPUTS
FIXED TERMINALS
Input Voltage: 24V or 120V AC/DC
Input/Output: Multiple I/O interfaces
Operating Temperature: -20°C to +70°C
Humidity: humidity of up to 95% (non-condensing)
Excellent spectral uniformity of ± 0.1 dB
100 dB maximum attenuation
Monitor output option
Ultra-low insertion loss
Ideal for BER testing
Singlemode and multimode
Card type PCIe x16
Graphics memory :128 MB DDR2
Form factor (card/bracket) :ATX/ATX
Carddimensions1:6.6” x 4.38” / 16.76 x 11.13 cm
Connectors :DVI-I x 2
Connector adapters :2 DVI-I to HD15
Max displays per card :2