SCALANCE XB008G
UNMANAGED INDUSTRIALETHERNET SWITCH
FOR 10/100/1000MBIT/S
W. 8 X 10/100/1000MBIT/S
RJ45- ELECTRICALPORTS
FOR ESTABLISHING SMALL STAR- ANDLINE
TOPOGRAPHIES
LED-DIAGNOSTICS, IP20
DP/AS-Interface F-Link
gateway PROFIBUS DP/AS-i
for safety-oriented data transmission
from ASIsafe to PROFIBUS-DP-PROFIsafe
Master profile M3/M4 according to
AS-i specification V3.0
degree of protection IP20
spring-loaded terminals
Aluminum body with 304stainless steel sleeve
1.1 kg (2.4 lb) typical,without fittings
28 3300 XL 8mm probe
selectablehazardous area approvals
05 0.5 m (20 in)
04 One 3/4-14 NPT plug only
023/4-14 NPT
Model Number: A5E00063020
Type: Switching Power Supply
Input Voltage: 120/230V AC (auto-ranging)
Input Frequency: 47-63 Hz
Output Voltage: 24V DC
Output Current: Insert specific current, 5 A
Output Power: Insert specific power 120 W
Efficiency: Up to [insert specific efficiency, 90%
Model Number: 6DR5220-0EM21-0AA0
Product Family: SIPART PS2
Input Signal: 4 to 20 mA
Operation Type: Double-acting for bidirectional control
Pneumatic Connection Thread: 1/4 inch NPT
Enclosure Material: Durable polycarbonate housing
Ambient Temperature Range:-30 to 65 °C
Board Compatibility:Vibration Terminal Board (TVBA)
Channels Thirteen for Proximity and Vibration
Common Mode Voltage Min:5 VDC
Frame Rates:3.125, 6.25, 12.5, 25, 50, and 100 Hz
Functional Acronym/Abbreviation:PVIB
LED Indicators:4
Probe Power:-24 VDC, 12 mA load per transducer
Status LEDs:Attn, Pwr, Link, TxRx
Part Status:Not For New Designs
For Measuring:AC/DC
Current - Sensing:1000A
Frequency:DC ~ 150kHz
Linearity:±0.1%
Accuracy:±0.4%
Voltage - Supply:24V
esponse Time:1µs
Current - Supply (Max):20mA
Operating Temperature:-10°C ~ 70°C
SIMATIC S7-300
CP 340 COMMUNICATION PROCESSOR
backplane bus 5 V DC, max.:220 mA
Power loss, max.:0.85 W
Transmission rate, min:2.4 kbit/s
FB length in RAM, max.:2 700 byte
Model Number: S79220-A3919-F000-01
Input Voltage: 24V DC
Power Consumption: < 10W (energy-efficient design)
Operating Temperature: -10°C to 50°C (14°F to 122°F)
Storage Temperature: -20°C to 60°C (-4°F to 140°F)
Humidity Range: 10% to 90%
Ethernet: 10/100 Mbps (RJ45 connector)
RS-485: For connecting peripheral devices
Series:PLC series
Data Format:BDC or Natural Binary
No. of channels:Four (4) isolated channels
Output signal:+/- 10 VDC
Voltage Range:1-5 V dc, 0-10 V dc, +/- 10 V dc
Output signal ranges:+1 to +5 VDC; -10 to +10 VDC and 0 to +10 VDC
Current Range:N/A
Module resolution:12 bits
Backplane Current:1.5 Miliamperes
Model Number: XM-500, 1440-GWEN2DN
Input Voltage: 24V DC
Power Consumption: < 5W
Operating Temperature: -20°C to 60°C (-4°F to 140°F)
Storage Temperature: -40°C to 85°C (-40°F to 185°F)
Humidity Range: 5% to 95%
220-230V 50Hz / 230-240V 60Hz
Model Number: A30-30-10
Rated Operational Current (Ie): 30 A
Rated Operational Voltage (Ue): Up to 690 V AC
Control Voltage: 24-230 V AC/DC
Poles: 3 (3-phase)
Mechanical Life: Up to 10 million operations
Electrical Life: Up to 1 million operations
Enclosure Rating: IP20
ACS510-550 Frequency converter
Model Number: 3X4K7 10028493B
Input Voltage: 3-phase, 380-480 V AC
Output Voltage: 0-480 V AC
Frequency Range: 0-400 Hz
Rated Power: 7.5 kW (10 HP)
Current Rating: 16 A
Enclosure Rating: IP20 (suitable for panel mounting)
Cooling Method: Air-cooled
Nom Input Voltage:220 Volts AC
Input Voltage Range:194-264 Volts AC
Max Real Input Power:56 Watts
Max Apparent Input Power:89 VA
Max Xformer Load:140 VA
User Output Current:N/A
Backplane Output Current:8 Amperes (at 5 Volts DC)
Frequency:47-63 Hertz
Manufacturer: ABB
Model: RINT-6512C
Type: Main Circuit Interface Board
Function: Interfaces between control logic and power circuits in drives/inverters.
Voltage Rating: 24V DC
Temperature Range: -20°C to +70°C.
Humidity: Up to 95% (non-condensing).
Manufacturer: ABB
Model: RINT-6421C
Type: Driver Board
Operating Voltage: Typically 24V DC
Current Hadling: Low to moderate
Isolation: Galvanic isolation for control and power stages
Protection: Over-current, over-voltage, short-circuit protection
Temperature Range: -20°C to +70°C
Humidity: Up to 95% (non-condensing)
Operating voltage UB 24 VDC
Upper limit value uB(t)max 30 V
Lower limit value uB(t)min 21 V
Current consumption Imax 1.5 A; standby current 270 mA
Fuse IS 4 A time-lag
Digital inputs Signal log 0 = 0 to 5 Vlog 1 = 16 V to U
Range U ±10 V
Input resistance Re > 100 kΩ, > 10 MΩ for input AI2
Resolution 5 mV for range ±10 V
Processor-based VME (VMEbus) single board computer
Up to 512MB PC133 SDRAM
Built-in SVGA support with 4 Mbytes DRAM display cache
Built-in dual 10/100 Mbit Ethernet
IDE drive support
Floppy drive support
Two RS232 serial ports
Dual USB ports
Real-Time clock/calendar
Front panel reset switch
Miniature speaker
Keyboard/Mouse port
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
1 PORT CHANNEL
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
PROFIBUS INTERFACE CARD
1 PORT CHANNEL
Operating Temperature Range: -40°C to +70°C.
Power Consumption: Maximum of 5W
Data Transfer Rate: Up to 400 Mbps
Digital I/O Channels: Provides 32 digital
3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector with
connectorprotector, standard cable
00 Not required
CONTROL BOARD
DIGITAL SIGNAL PROCESSOR
60 MHZ
MARK VI
Clock Frequency:Up to 200 MHz
Program Memory:512 KB Flash
Input Voltage:Typically 12 V DC
Power Consumption:Approximately 3–5 W
Number of input channels
16-channel input, isolated
Input signal 4 to 20 mA
Allowable input current 24 mA
Accuracy ±0.1% of full scale
Data refresh cycle 10 ms
Transmitter power supply 24.0 to 25.5 V
Temperature drift Max. ±0.01%/°C
Number of I/O channels
8-channel input, isolated channels
I/O signal 4 to 20 mA
Allowable input current 25 mA
Accuracy ±16 µA
Data update period 10 ms
Temperature drift ±16 µA/10 °C
Maximum currentconsumption
360 mA (5 V DC), 450 mA (24 V DC)
SIMATIC DP
ELECTRONIC MODULE
ET200S: 2AI HIGH SPEED I2WIRE
0 - 20MA, 4 - 20MA, 15BIT
15 MM WIDTH,FOR 2-WIRE
TRANSDUCER,CYCLE TIME OF
THE MOD.: 0.1MS,
WITH LED SF (GROUP FAULT)
High-Speed 1 MS/s 16-bit Isolation Module
(4 ch) High Noise Immunity
Suitable for testing and long-term monitoring
for power generators and multi-output power supplies.
Provides dynamic analysis of multi-channel
data recording applications.
Applicable to DL350 and DL850 series
FREQUENCY RANGE:45 Hz to 65 Hz
VOLTAGE RANGE:90 V to 305 V (L-N)
DC OUTPUT:5 A DC 12 V DC
RIPPLE AND NOISE:<1%
EFFICIENCY:>80%
LINE:<0.001% Vo
LOAD:1% Vo
AC SUPPLY VOLTAGE RANGE
90 V to 250 V (L-N)
DC OUTPUT
5 A DC 12 V DC at 13.7 V DC
RIPPLE AND NOISE:<1%
EFFICIENCY:>80%
REGULATION LINE:<0.001% Vo
LOAD:1% Vo
CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
460 mA at 12 V, 245 mA at 24 V
MAXIMUM STANDBY CURRENT
375 mA at 12 V, 200 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
CONTINUOUS VOLTAGE RATING
5 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 100 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
530 mA at 12 V, 280 mA at 24 V
MAXIMUM STANDBY CURRENT
320 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Synchronising & Load Sharing Auto Start Control Module
CONTINUOUS VOLTAGE RATING
8 V to 35 V continuous
CRANKING DROPOUTS
Able to survive 0 V for 50 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
460 mA at 12 V, 245 mA at 24 V
MAXIMUM STANDBY CURRENT
375 mA at 12 V, 200 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
Able to survive 0 V for 50 mS
providing supply was at least 10 V
before dropout and supply recovers to 5 V
This is achieved without the need for internal batteries
LEDs and backlight will not be maintained during cranking
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 96 mA at 24 V
MAXIMUM STANDBY CURRENT
51 mA at 12 V, 47 mA at 24 V
Able to survive 0 V for 50 mS
providing supply was at least 10 V
efore dropout and supply recovers to 5 V
This is achieved without the need for internal batteries.
LEDs and backlight will not be maintained during cranking
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
MAXIMUM OPERATING CURRENT
85 mA at 12 V, 96 mA at 24 V
MAXIMUM STANDBY CURRENT
51 mA at 12 V, 47 mA at 24 V
MAXIMUM SLEEP CURRENT
35 mA at 12 V, 32 mA at 24 V
MAXIMUM DEEP SLEEP CURRENT
<10 uA at 12 V, <10 uA at 24 V
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for up to 1 Minute
CRANKING DROPOUTS
Able to survive 0 V for 100 mS,
providing supply was at least 10 V
before dropout and supply recovers to 5 V.
This is achieved without the need for internal batteries
MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V
MAXIMUM STANDBY CURRENT
330 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
CONTINUOUS VOLTAGE RATING
8 V to 35 V Continuous
5 V for up to 1 minute
MAXIMUM OPERATING CURRENT
510 mA at 12 V, 240 mA at 24 V
MAXIMUM STANDBY CURRENT
330 mA at 12 V, 160 mA at 24 V
CHARGE FAIL/EXCITATION RANGE
0 V to 35 V
Operating Voltage Range: 8 V to 35 V
Cranking Dropout:
Able to withstand 0 V for 50 ms,
provided the supply was at least 10 V
before the dropout and recovers to 5 V
afterward. No internal battery is required.
Maximum Operating Current:
100 mA at 12 V, 105 mA at 24 V
Maximum Standby Current:
60 mA at 12 V, 55 mA at 24 V
Maximum Sleep Current:
40 mA at 12 V, 35 mA at 24 V
DSE 6120 MKII is an
Auto Mains (Utility) Failure Control Module
developed to provide a wide range of
operating and monitoring features for
single diesel and gas gen-sets
Back-lit icon LCD display
Front panel editing
LED and LCD alarm indication
Power Save mode
CAN and Magnetic Pick-up/Alt.
versions available (specify on
ordering)
PC configurable
6 Digital inputs
4 Outputs (2 configurable on
Magnetic Pick up/Alt., 4 configurable on CAN version)
Configurable timers and alarms
Alternative configuration
Remote Start input
Generator voltage display
Fan Type: Axial Fan
Voltage: 230V AC
Frequency: 50/60 Hz
Power Consumption: 120W
Current Consumption: 0.55A
Speed: 1400 RPM
Airflow: 2200 m³/h (1295 CFM)
Operating Temperature Range: -30°C to +60°C
suitability for use Swappable lens with C-mount connection
suitability for operation lens for MV440
mechanical datacolor black
design, dimensions and weight
sheight 37.2 mm
diameter 29.5 mm
120 Volts Doubler Mode:Yes
Continuous Output Current (0-peak):5.7 Amperes
Integrated AC (EMC) Line Filter:No
Input Voltage:120/240 Volts (AC), 1 Phase
Power Rating:800 W
Part Number/Catalog No.:2097-V31PR2-LM
Safe Torque-Off:Yes
Module Width:Single Slot
Compatible controllers:SLC 5/02 or later
Pass through:Supported
Communication Port:One (1) DeviceNet
Data Transfer speed:125Kbps
Storage Temperature:-40 to 85 C (-40 to 185 F)
Vibration:Tested 5 g @ 10-500Hz per IEC 68-2-6
Operating Shock:30 g peak acceleration, 11(+1)ms pulse width
Series:SLC 500
Module Type:DeviceNet Scanner Module
Scan I/O:Yes
Backplane Current (5 Volts):500 milliamps