DRIVE MAIN BOARD
Control Voltage: +24 V DC (±10%)
Power Handling:75–150 kW
Operating Temperature: 0°C to +55°C
Storage Temperature: -25°C to +70°C
Humidity: Up to 95%
LINE MODULE
SINAMICS / SIMODRIVE 611 BASIC
LINE FILTER FOR 55KW ACTIVE
LINE MODULE INPUT: 3AC 380-480V
50/60HZ
CONTROL MODULE
CONTROL MODULE
CLOSED-LOOP / OPEN-LOOP
CUPM
MOTION CONTROL PERFORMANCE 2
FOR SIMOVERT MASTERDRIVES
Power Interface Board
6RY18030-DA02
Power Interface Board
Input Voltage:+24 V DC
Optional Input Ranges: 10~30 V DC
Continuous (Logic/Control): 1–3 A
Rush (Reley Outputs): 5–10 A
Operating Temperature: 0°C to +55°C
Allocation board
Allocation board
C98043-A7126-L1
Control Circuit: 24 V DC ±10%
Communication: +15 V DC/-15 V DC
Screw-terminals for ≤1.5–2.5 mm² wires
Temperature: 0°C to +55°C (derating at >+40°C).
Humidity: ≤90% non-condensing
POWER INTERFACE BOARD
POWER INTERFACE BOARD
Terminals C98043-A7105-L1
SCREW CLAMP TERMINALS
W/ FUNCTIONAL SAFETY
REPLACES 6RY1803-0DA01
Interconnect Cable
CABLE EXTENSION 26FEET
Cable Length:26 feet (7.92 meters)
Cable Type:Shielded Foil-Braid Coaxial
Center Conductor: Tinned Copper (20 AWG)
Insulation:High-grade PFAS
Dual-Layer: Aluminum Foil + 85% Braided Copper
Velomitor CT Transducer
Low-Frequency
Measures Casing Vibration Velocity
Compatible with Cooling Towers and
Air-Cooled Heat-Exchanger Fan Assemblies
3300 NSv Proximity Probes
330902 3300 NSv Probe
1/4-28 UNF thread,with armor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required
3300 NSv Extension Cable
065 6.5 meters (21.3 feet)
05With stainless steel armor
without FEP jacket
withconnector protector
05 Multiple Approvals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
05 CSA, ATEX, IECEx Approvals
Ingersoll Rand Proximity Probe
3300 NSv · 25" Length
Power Supply:-18 to -24 V DC
Output Signal: -2 to -18 V DC
Sensitivity: 200 mV/mil (7.87 V/mm)
Measurement Range: 0–80 mils (0–2.0 mm)
Frequency Response: 0 to 10 kHz
Probe: -30°C to +150°C (-22°F to +302°F)
Cable: Up to +125°C (°C short-term)
Power interface board
power interface
C98043-A7003-L1 incl
painted terminals
Power Side:240-690 V AC
Control Voltage: 24 V DC
Terminal Current Rating: 5–20 A
Thermal Compliance:500–600 W
Excitation board
Excitation board
power unit 15 A 4Q
C98043-A7111-L1
Continuous Output Current: 15 A
Output: 160–400 V DC
Input: Logic supply 24 V DC ±10%
Isolation: ≥2500 V AC
Temperature: 0–55°C (non-condensing)
Relative Humidity: ≤95%
Power Interface Board
AC: 120–480 V AC
DC Voltage Input: 24 V DC ±15%
Relay Outputs:10 A @ 250 V AC
Current Handling: Up to 100 A
Isolation Voltage: Up to 2.5 kV
Secondary Voltage: 12 V/24 V DC
POWER INTERFACE BOARD
POWER INTERFACE BOARD
RELAY OUTPUTS
WITH ON-BOARD TRANSFORMERS
Signal Interface:24 V DC
Number of Relays:8 to 16 channels
AC Load: 240 V AC @ 8–10 A
DC Load: 24–48 V DC @ 5-8 A
6RY1703-0GA01
PC BOARD
BACK PANEL
REAR
6RY1703-0GA01
Contact Rating: 5‒10 A @ 24–230 V AC/DC
Isolation Class:24 V AC/DC isolation
Control Side: 24 V DC
Power Circuit: Up to 690 V AC three-phase
POWER INTERFACE BOARD
POWER INTERFACE BOARD
RELAY OUTPUTS
WITH ON-BOARD TRANSFORMERS
Contact Configuration:Typically SPDT or DPDT relays
Maximum Switching Voltage:250 V AC/DC
Current Rating:5–15 A per relay
Purpose:24 V AC/DC to lower voltage
Control Input(s): 24 V DC
FIELD POWER SUPPLY PC BOARD
PC BOARD ASSEMBLY
FIELD POWER SUPPLY PC BOARD
Nominal Input: 110-240 V AC
Frequency: 47-63 Hz
Voltage Output: Likely 24 V DC
Operating Temperature: Range of 0°C to +60°C
Humidity Tolerance: ≤95%, non-condensing
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.