CONTROL MODULE
CONTROL MODULE
E300 OVERLOAD RELAYS
193 IEC RELAY
I/O ONLY
6 INPUTS / 3 RELAY OUTPUTS
24 V DC CONTROL VOLTAGE
Overload Relay
COMMUNICATION MODULE
E300 OVERLOAD RELAYS
IEC
DEVICENET
193/592 IEC/NEMA
Analog Input Module
Channels: 15
Signal Types:
standard current input:4-20 mA
voltage inputs0-5 VDC
Input Range: 0-10 VDC, ±10 VDC,
Signal Conversion: 16-bit
Input Impedance: High input impedance f
or accurate measurements without significant loading.
Input Accuracy: Typically ±0.1%
Operating Temperature: -20°C to +60°C
Analog output module
Channels: 16 or 32
current output:4-20 mA
voltage output:0-10 VDC or ±10 VDC
Output Range:0-10 V, ±10 V, 4-20 mA
Resolution: 16-bit
Accuracy:
±0.1% of full scale for voltage outputs
±0.1% of full scale for current outputs
NSv Proximitor Sensor
3300 NSv Probe
3/8-24 UNF thread
withoutarmor
5.0 metre (16.4 feet) systemlength
panel mount
0 0 Not required
NSv Proximity Sensor
7.0 5.9 ± 0.9
Extension cabledc resistance
Center conductor: 0.220Ω/m (0.067 Ω/ft)
RecommendedGap Setting 1.0 mm (40 mils)
IncrementalScale Factor 7.87 V/mm (200 mV/mil)
OperatingTemperature-52°C to +177°C
StorageTemperature-52°C to +177°C (-62°F to+351°F)
Analog output Module
SIMATIC S7-300
Analog output SM 332
isolated, 2 AO, U/I
resolution 11/12 bits
20-pole
Removing/inserting
with active backplane bus possible
ANALOG INPUT MODULE
SIPLUS S7-300
SM 331-20-pole -25...+70°C
with conformal coatingbased on
Analog input isolated 2 AI
Resolution 9/12/14 bits
U/I/thermocouple/resistor
alarm diagnostics
1x 20-pole
Removing/inserting with active backplanebus
Servo Control
Design Euro card
Functionality Valve specific
valve parametersfixed
User software Application parameters from
PC viauser software ProVRD
Operating system MS-DOS
Supply voltage 18...30VDC
Solenoid current ranges 0,8 / 2,7 / 3,5A
Current consumption max. 2,0A
Pre-fuse 1,6 / 3,15A fast
Ambient temperature 0...+50°C
Connection DIN 41612F, 48-pole
Command signal inputs 0...+/- 10V
VME Interface Control Card
Work With MV Series Controllers
6U Single-Slot VME Modules
running at 40 MHz
can be configured with 2, 4, or 8 MB
Gateways
PROFIBUS DP-V0 Master
to Modbus RTU Slave
Product Category: Gateways
Product: X-Gateways
Data Rate: 12 Mb/s
Interface Type: Ethernet, USB
IP Rating: IP20
Operating Supply Current: 200 mA
Product Type: Gateways
Series: Anybus X-Gateway
Subcategory: Ethernet & Communication Modules
Communication Module
Tricon
TCM SERIES
2 X NET LINK PORTS
4 X 9 PIN SERIAL PORTS
1 X 9 PIN DEBUG PORT
Current/Ground Fault Sensing Module
Current/Ground Fault Sensing Module
for E300 Overload Relays,
0.5-30A
DIN Rail / Panel Mount,
with Line- and Load-Side Power Conductor Terminals,
Directly Replaces 193-ECPM2
Series A
Operator Panel
Operating Temperature 0° to 50° C
Storage Temperature -20° to 80° C
Operating Humidity 5 to 95% (non-condensing)
Air Composition No corrosive gases permitted
Power Budget Requirements 5 VA @ 8--30 VDC
Safety-Related Controller
Number of outputs 8
Output voltage L+ minus 2 V
Minimum load 2 mA for each channel
Internal voltage drop max. 2 W at 2 A
Leakage current (with lowlevel)max. 1 mA at 2 V
Number of counters 2
Inputs 3 on each (A, B, Z)
CPU module
Processor Atom E3815 1.46 GHz
Main 256 MB with ECC
Static RAM 2 MB with ECC
backed up by battery
1 GB on-boad flash memory
SDHC (4 to 32 GB) Class 10
D-sub 9 pins, male (*2)
Full/Half duplex (software settings)
Synchronisation Asynchronous
CPU module
SH-4A (SH7730) 256 MHz
128 MB with ECC
1 MB with ECC, backed up by battery
128 MB on-board flash memory
RS-422/RS-485:
120 Ω built-in,
ON/OFF (DIP switch settings)
SB bus (single)
CPU module
Operation 0° to 55°C
Transportation/storage 40° to 85°C (*1)
Dust 0.3 mg/m3 or less
Resistance to corrosive gases
ANSI/ISA S71.04 Class G2 (Standard)
(ANSI/ISA S71.04 Class G3, option)
Resistance to vibration
0.15 mm P-P (5 to 58 Hz), 1 G (58 to 150 Hz)
Resistance to shock
15 G, 11 ms
(during power-off, for sine half-waves in XYZ-directions)
Altitude 2000 m or less
CPU module
High-performance
high-elibility modular controller
Memory with ECC
Low heat dissipation eliminates the need for a fan
Awealth of RAS features -CPU self-diagnostics
temperature monitoring. 1/0 diagnostics, and more
power supply module, local bus (SB bus)
and control network can all be duplexed
and all modules are hot-swappable
Can function as link active schedulers
(L ASs) for low-speed voltage mode (H1)
FOUNDATION Fieldbus segments
and link up FOUNDATION Fieldbus-enabled feld devices
CPU module
Processor Atom E3815 1.46 GHz
Main 256 MB with ECC
Static RAM 2 MB with ECC
backed up by battery
1 GB on-boad flash memory
SDHC (4 to 32 GB) Class 10
D-sub 9 pins, male (*2)
Full/Half duplex (software settings)
Synchronisation Asynchronous
4 Ethernet ports : RJ45 modular jacks
Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.