Repetitive Peak Off‑State Voltage:1 600 V DC
Average On‑State Current:460 A
Critical dI/dt:250 A/µs
Non‑Repetitive I²t:1 200 kA²·s
On‑State Voltage Drop:1.44 V
Turn‑Off Time: ≤ 200 µs
Insulation Test Voltage:1.5 kV AC
Thermal Resistance:0.074 K/W
Description: Main Power (IGBT) Module Board
Input Line Voltage:380 – 480 V AC, 3‑phase
Input Frequency:50 / 60 Hz
DC‑Link Voltage (typical):580 – 650 V DC
Rated Output Current:Up to 250 A (frame‑dependent)
Switching Devices:Discrete IGBT modules
Insulation Test Voltage:1.5 kV AC
Description: Main power (IGBT) module
Input Line Voltage:380 – 480 V AC
Input Frequency:50 / 60 Hz
DC‑Link Voltage (typical):580 – 650 V DC
Rated Output Current:Up to 250 A
Insulation Test Voltage:1.5 kV AC
Description: Main power (IGBT) module
Input Line Voltage:380 – 480 V AC
Input Frequency:50 / 60 Hz
DC‑Link Voltage (typical):580 – 650 V DC
Rated Output Current:Up to 250 A
Insulation Test Voltage:1.5 kV AC
SINAMICS SM120 Modular Motor Control System
Isolation Rating:1.5 kV AC
Operating Temperature:–25 °C to +60 °C
Storage Temperature:–40 °C to +85 °C
Relative Humidity:5 % to 95 % RH
Supported baud rates: Up to 800 Mbp
Data Rates:Up to 12 Mbps for PROFIBUS DP
INTERFACE MODULE
PC BOARD
MICROMASTER 430/440 series
Nominal Supply Voltage:480 – 690 V AC
Supply Frequency:50 – 60 Hz
Logic Supply Internal:24 V DC rail
Operating Ambient Temp:–25 °C to +60 °C
Storage Temp:–40 °C to +85 °C
Relative Humidity:5 % to 95 % RH, non‑condensing
Family: MICROMASTER 430 /440
Nominal DC‑link Voltage:580 – 650 V DC
Maximum DC‑link Voltage (cap rating):800 V DC
Capacitance (effective):330 µF ± 20 %
Bleeder (Discharge) Resistor:100 kΩ / 5 W
Ripple Current Rating:up to 50 A rms
Insulation Test Voltage:1.5 kV AC
From the vibro-meter® product line
Ex certified versions for use in hazardous areas
TQ401 conforms to API 670 recommendations
5 and 10 m systems
Temperature-compensated design
Frequency response:DC to 20 kHz (−3 dB)
Measurement range:2 mm
Temperature range:−40 to +180 °C
From the vibro-meter® product line
Ex certified versions for use in hazardous areas
TQ401 conforms to API 670 recommendations
5 and 10 m systems
Temperature-compensated design
Frequency response:DC to 20 kHz (−3 dB)
Measurement range:2 mm
Temperature range:−40 to +180 °C
Allocation Board
painted with functional safety
A5E43710360
Signal Voltage:+15V / –15V
Max Analog I/O Levels:±10V DC
±10V DC :24V
Resolver/Encoder/Tacho: ≤300kHz input
Current Isolation:1.9kV tested rms
Normalizing module
ABI Adaption Board
single/master
Voltage ranges: 380V–600V AC
Operating V Logics Side:24V + 5V DC
Analog I/O Rating:-10 V- +10 V
Power Consumption:15 W max
Operating Humidity:< 95 % Noncon
voltage measurement
CM C98043-A7117-L1
Input Power AC:3‑phase (50‑60 Hz)
DClink Output:400‒610 VDC
Max SCR trigger freq:5kHz
Ambient working:-25°C-+ 55°C
Firing pulse transformer
up to 1000 A DCM
Primary Voltage Range:5–15V DC Pulse
Secondary Output Voltage:20Vpk
Trigger Current Transfer:≥150mA gate trigger output
Signal Rise Time:<0.1μs (typical)
Isolation Voltage:≥4kV AC RMS