ALL MANUFACTURERS


ALL MANUFACTURERS
Please click on the part number or image to view product details.
show:
2751-2775 of 80420
< page << 111 of 3217 >
General Electric

Analog Input Module

Input Channels: 16 Analog input channels
Voltage :0–10 VDC, ±10 VDC
Current: 4–20 mA
Sampling Rate: 500 Hz
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically 5 W
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)

General Electric

Analog Input Module

Input Channels: 12 Analog input channels
Signal Type:Voltage 0-10 VDC
Current :4-20 mA
Accuracy: ±0.1% of full scale
Nominal Operating Voltage: 24 VDC
Voltage Range: 20.4 to 30 VDC
Power Consumption: Typically <6 W

General Electric

Speed Protection Module

Nominal Operating Voltage: 125 VDC
Voltage Range: 85–250 VDC
Power Consumption: Typically <10W
Range: 0–100,000 RPM
Accuracy: ±0.1% of full scale
Operating Temperature:-40°C to +70°C (-40°F to +158°F)
Storage Temperature:-40°C to +85°C (-40°F to +185°F)

General Electric

Speed Protection Module

Operating Voltage:125 VDC
Voltage Range: 85–250 VDC 
Power Consumption: typically <10W
Range: 0–100,000 RPM

Siemens

Yokogawa

PROCESSOR MODULE

SCP461-E1 
PROCESSOR MODULE
ENHANCED RFI
ISA STANDARD G3
FOR SSC60S
SSC60D

Yokogawa

Optical ESB Bus RepeaterModule

Function: ESB Bus optical transport function
Connection method: Star type connection 
Chain type connection 
Available for both star and chain type connection.
Number of connecting stage: Maximum two
Transmission distance: Maximum 5 km (total two stages) 
In case of Vnet/IP system with the R1.03 or later, 
the total distance of two stagesis maximum 10 km.
Current consumption: 0.5 A

Yokogawa

Current Output Module

Number of output channels 8 channels, module isolation
Rated output range 4 to 20 mA
Maximum range of guaranteed precision 1.25 to 23 mA
Output range 1.25 to 23 mA
Allowable load resistance @ rated range 230 to 600 Ω
Accuracy ±48 µA
Data update frequency 40 ms
Temperature drift ±16 µA/10 ºC
Withstand voltage 1.5 kV AC between output signal and system for 1 minute

Yokogawa

Output Module

Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line 
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum

Yokogawa

Output Module

Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
External power supply 24 V DC +20 %/–10 %
Output format Current source
Maximum load current 0.6 A/output line 
Minimum load current 35 mA
Load resistance range 40 to 685 Ω
Output response time 30 ms maximum

Yokogawa

Output Module

Number of outputs 4-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
External power supply 24 V DC +20 %/–10 %
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 2 A/output line
Minimum load current 100 mA
Load resistance range 12 to 240 Ω)
Maximum lamp load (*1) 1 A/output line

Yokogawa

Output Module

Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Maximum load current 0.6 A/output line
Minimum load current 35 mA
Load resistance range 40 to 685 Ω 
Output response time 30 ms maximum

Yokogawa

Input Module

Number of inputs 16-channel, module isolation
Input current 6 mA ± 20 %
Contact rating 24 V DC +20 % / -10 %
External power supply 24 V DC +20 % / -10 % 
Input response time 40 ms maximum
Withstand voltage (*1) (*2) 2 kV AC between input signal and system for 1 minute, 16-input line collectivelyconnected

Yokogawa

Current Input Module

Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Permissible input range 0 to 25 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute

Yokogawa

Current Input Module

Number of input channels 16 channels, module isolation
Rated input range 4 to 20 mA
Input impedance during Power-OFF 500 kΩ minimum
Data update frequency 40 ms
Temperature drift ±16 µA/10 °C
Withstand voltage 1.5 kV AC between input signal and system for 1 minute

Yokogawa

Output Module

Number of outputs 8-channel, module isolation
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 5 A minimum
Maximum leak current at output offstatus 1.6 mA
Output format Current source
Minimum load current 35 mA
Load resistance range 40 to 685 Ω 
Output response time 30 ms maximum

Yokogawa

Digital Output unit

Number of outputs 4-channel, module isolation 
Output voltage 24 V DC
Output voltage drop 1 V maximum
External power supply rating 24 V DC, 10 A minimum
Output format Current source
Maximum load current 2 A/output line (8 A in total output lines) (*4)
Minimum load current 100 mA
Load resistance range 12 to 240 Ω (*6)

Expansion Card

Product type:Controller
IP rating:IP20
Manufacturer:Carel
Power Supply:24Vac/Vdc
Accessory type:General Accessories
Board type:pCO expansions

Input Output Module

Analog Inputs:0-10V or 4-20m
Digital Outputs:24V DC
Analog Outputs: 0-10V or 4-20mA
Power Supply:24V DC
Digital Inputs: Typically 8 or 16 digital inputs

2-Phase Stepper Motor Driver

Operation method:Unipolar constant current drive
Applied Motor:2-phase stepper motor
Resolution:Intelligent type
Power supply:24-35VDC 
Max. Run Current:2A/Phase
Max. Current Consumption:3A
Number Of Axes:1-axis
Environment_Ambient temperature:0 to 50℃, storage: -10 to 60℃
Environment_Ambient humidity:35 to 85% RH, storage: 35 to 85% RH

Dynalco Digital Indicator Panel

Dynalco Part No.: LMD-120D
Description: Current Loop-Powered Digital Indicator
Input Signal: 4–20 mA or 10–50 mA, jumper-selectable
Loop Burden: 2 volts maximum, i.e. 100 Ohms at 20 mA
Display: 3½ digits standard; 
4½ digits with fixed zero at right-most digit. 
Selectable decimal point.
Span and zero adjust: 
25-turn potentiometers permit span adjustment from 
100 up to 2000 units, and zero adjustment 
from – 1000 up to +1000 units
Accuracy: 0.1% linearity, 
0.5% stability over the environmental range

Emerson

Control Techniques Drive

Voltage Rating:400V AC
Current Rating:45A at 400V
Frequency Range:0-500 Hz
Input Power: 3-phase 400V AC
Control Inputs/Outputs:0-10V or 4-20mA
Operating temperature range: Typically -10°C to +50°C
Storage temperature range: -40°C to +70°C

Synchronizing relay

SYNCHRONIZING RELAY
48/250 V
57-120 VAC

ABB

PULSE AMPLIFIER BOARD

Voltage Rating:24V DC
Input Signal Type:24V
Operational Temperature Range: -20°C to +70°C
Part Number:61073027C

POWER SUPPLY

POWER SUPPLY
230VAC
50/60HZ

show:
2751-2775 of 80420
< page << 111 of 3217 >
All product and service marks contained herein are the trademarks or service marks of their respective owners.