ALL MANUFACTURERS


ALL MANUFACTURERS
Please click on the part number or image to view product details.
show:
2776-2800 of 80420
< page << 112 of 3217 >
Allen-Bradley

GuardLogix 5580 Safety Controller

User memory:10 megabytes
Safety memory:5 megabytes
Digital I/O / Analog I/O:128,000 / 4000 max
Ethernet performance:10/100/1000 megabits per second
Current draw at 1.2 Volts DC:5.0 milli Amps
Current draw at 5.1 Volts DC:1.2 Amps

Bently Nevada

3300 XL 8 mm Proximity

3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx  Approvals

Bently Nevada

3300 XL 8 mm Proximity

3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx  Approvals

Bently Nevada

3300 XL 8 mm Proximity

3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required

Bently Nevada

3300 NSv Proximity Probes

3300 NSv Probe
3/8-24 UNF thread,without armor
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector,
standard cable
00 Not required

Bently Nevada

Proximity Probe

Armored and Unarmored Options
Multiple Connector Options
Complete Interchangeability of Units and Cabling
Compact Form Factor
-18 to -24VDC VT
Wide Temperature Range: -55°C to 100°C
11mm Probe Diameter


Bently Nevada

3300 XL 8mm Proximity

3300 XL 8 mm Probe
3/8-24 UNF thread,without armor
0 2 Miniature coaxial ClickLocconnector
standard cable
0 0 Not required

Bently Nevada

3300 XL Proximitor Sensor

3300 XL Proximitor Sensor
03 Armored cable with 
connectorprotector
05 CSA, ATEX, IECEx  Approvals

Bently Nevada

3300 XL Proximitor Sensor

3300 XL Proximitor Sensor
03 Armored cable with 
connectorprotector
00 Not required

Bently Nevada

3300 NSv Probe

3300 NSv Probe
M10X1 thread, witharmor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc 
connector,standard cable
00 Not required

Bently Nevada

Proximity Probe Housing Assemblies

Aluminum body with 304stainless steel sleeve
28 3300 XL 8mm probe, 
selectablehazardous area approvals
05 0.5 m (20 in)
00 Without fittings
023/4-14 NPT

Bently Nevada

3300 XL 8 mm Proximity

3300 XL 8 mm Probe
3/8-24 UNFthread
without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector 
with connectorprotector, standard cable
00 Not required

Bently Nevada

3300 XL 11 mm Probe

3300 XL 11 mm Probe
5/8-18 UNF-2A, without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector 
with connectorprotector, standard cable
00 Not required

Allen-Bradley

CONTROL MODULE

4139145401S1FX
CONTROL MODULE
SMC-FLEX
STANDARD
120-240 VAC
FLEX QUICK START
150-FS1FX

Yokogawa

RTD Input Module

Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C 
Storage Temperature:-40°C to +85°C

Yokogawa

Digital input Module

Input Voltage:24V DC
Input Current:10-20 mA
Signal Input Range:0-24V DC
Input Channels:8 or 16
Operating Temperature:-10°C to +60°C 
Storage Temperature:-40°C to +85°C

Yokogawa

Fieldbus Communication Module

Input Voltage:24V DC
Current Consumption:Typically 100-200 mA
Fieldbus Power:24V DC 
Operating Temperature:Typically -10°C to +60°C
Storage Temperature:-40°C to +85°C

Yokogawa

CANopen Communication Module

Communication profile CiA 301 
Number of installed NFLC121 modules 4 max. for FCN-500
Number of slave devices 126 slave devices per 
CANopen Communication Module
Node Bootup
SYNC producer
Heartbeat Consumer/Producer

Yokogawa

Relay Output Module

Number of output channels 16
Rated applied voltage 24 to 125 V DC 
100 to 240 V AC, 50/60 Hz
Output response time 12 ms or less
Maximum current consumption 780 mA (5 V DC)
External connection Pressure clamp terminal

Yokogawa

Frequency Input Module

Number of input channels 8, isolated channels
Input signal (*1) Contact ON/OFF, voltage pulse
Input frequency 0.1 Hz to 10 kHz
Frequency accuracy 0.1% of reading
Minimum input pulse width 40 μs
Shunt resistance Select from OFF/1000 Ω
Pull-up resistance 68 kΩ (12 V DC or 24 V DC)
Data refresh cycle 10ms
Maximum current consumption 300 mA (5 V DC), 400 mA (24 V DC)

Yokogawa

Power Supply Module

100 to 120 V AC
Duplex configuration: Possible
Hot-Swap: Possible
Rated output: +5.1 V DC, 7.8 A
Analog field power supply: Input: 24 V DC ±10 %, 4 A, 
Duplexed (matching-diode)• LED: SYS 
(5 V system power output ON)
FLD (24 V field power supply ON)
Checking terminals: +5 V, +24 V

Yokogawa

SB bus repeat module

Transmission method Serial communication
Baud rate 128 Mbps
Transmission distance Max. 8 m per line
Extension units Max. 2 units
Duplex configuration Possible
Supplyvoltage 5 V DC±5%
Currentdissipation Max. 500 mA

Yokogawa

Power supply module

Rated input voltage:220 to 240 V AC
Input voltage range:170 to 264 V AC (rms)
Input frequency:47 to 66 Hz (Rating: 50/60 Hz)
Input current: Max. 0.7 A
Fuse rating:3.15 A
Leak current Max. :1 mA
Withstanding voltage:3000 V AC for 1 minute
Insulation resistance:50 MΩ at 500 V DC

Yokogawa

Analog Input Module

Input signal 4 to 20 mA 
Allowable input current 24 mA 
Accuracy ±0.1% of full scale 
Overcurrent protection Provided 
Data refresh cycle 10 ms
Input step response time 100 ms
Temperature drift Max. ±0.01%/°C

Yokogawa

Base module

Operation -40 to +70 °C 
Transportation/storage -40 to +85 °C
Dust 0.3 mg/m3 or less
Protection class IP20
Altitude 3000 m or less
Electric field 3 V/m or less (26 MHz to 1 GH
Magnetic field 30 A/m (AC) or less, 400 A/m (DC) or less

show:
2776-2800 of 80420
< page << 112 of 3217 >
All product and service marks contained herein are the trademarks or service marks of their respective owners.