GuardLogix 5580 Safety Controller
User memory:10 megabytes
Safety memory:5 megabytes
Digital I/O / Analog I/O:128,000 / 4000 max
Ethernet performance:10/100/1000 megabits per second
Current draw at 1.2 Volts DC:5.0 milli Amps
Current draw at 5.1 Volts DC:1.2 Amps
3300 XL 8 mm Proximity
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity
3300 XL 8 mm Probe
3/8-24 UNFthread, without armor
10 1.0 meter (3.3 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity
3300 XL 8 mm Probe
3/8-24 UNFthread, with armor
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
3300 NSv Proximity Probes
3300 NSv Probe
3/8-24 UNF thread,without armor
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector,
standard cable
00 Not required
Proximity Probe
Armored and Unarmored Options
Multiple Connector Options
Complete Interchangeability of Units and Cabling
Compact Form Factor
-18 to -24VDC VT
Wide Temperature Range: -55°C to 100°C
11mm Probe Diameter
3300 XL 8mm Proximity
3300 XL 8 mm Probe
3/8-24 UNF thread,without armor
0 2 Miniature coaxial ClickLocconnector
standard cable
0 0 Not required
3300 XL Proximitor Sensor
3300 XL Proximitor Sensor
03 Armored cable with
connectorprotector
05 CSA, ATEX, IECEx Approvals
3300 XL Proximitor Sensor
3300 XL Proximitor Sensor
03 Armored cable with
connectorprotector
00 Not required
3300 NSv Probe
3300 NSv Probe
M10X1 thread, witharmor
10 1.0 meter (39 in)
02 Miniature coaxial ClickLoc
connector,standard cable
00 Not required
Proximity Probe Housing Assemblies
Aluminum body with 304stainless steel sleeve
28 3300 XL 8mm probe,
selectablehazardous area approvals
05 0.5 m (20 in)
00 Without fittings
023/4-14 NPT
3300 XL 8 mm Proximity
3300 XL 8 mm Probe
3/8-24 UNFthread
without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
3300 XL 11 mm Probe
3300 XL 11 mm Probe
5/8-18 UNF-2A, without armor
10 1.0 meter (3.3 feet)
01Miniature coaxial ClickLocconnector
with connectorprotector, standard cable
00 Not required
CONTROL MODULE
4139145401S1FX
CONTROL MODULE
SMC-FLEX
STANDARD
120-240 VAC
FLEX QUICK START
150-FS1FX
CANopen Communication Module
Communication profile CiA 301
Number of installed NFLC121 modules 4 max. for FCN-500
Number of slave devices 126 slave devices per
CANopen Communication Module
Node Bootup
SYNC producer
Heartbeat Consumer/Producer
Relay Output Module
Number of output channels 16
Rated applied voltage 24 to 125 V DC
100 to 240 V AC, 50/60 Hz
Output response time 12 ms or less
Maximum current consumption 780 mA (5 V DC)
External connection Pressure clamp terminal
Frequency Input Module
Number of input channels 8, isolated channels
Input signal (*1) Contact ON/OFF, voltage pulse
Input frequency 0.1 Hz to 10 kHz
Frequency accuracy 0.1% of reading
Minimum input pulse width 40 μs
Shunt resistance Select from OFF/1000 Ω
Pull-up resistance 68 kΩ (12 V DC or 24 V DC)
Data refresh cycle 10ms
Maximum current consumption 300 mA (5 V DC), 400 mA (24 V DC)
Power Supply Module
100 to 120 V AC
Duplex configuration: Possible
Hot-Swap: Possible
Rated output: +5.1 V DC, 7.8 A
Analog field power supply: Input: 24 V DC ±10 %, 4 A,
Duplexed (matching-diode)• LED: SYS
(5 V system power output ON)
FLD (24 V field power supply ON)
Checking terminals: +5 V, +24 V
SB bus repeat module
Transmission method Serial communication
Baud rate 128 Mbps
Transmission distance Max. 8 m per line
Extension units Max. 2 units
Duplex configuration Possible
Supplyvoltage 5 V DC±5%
Currentdissipation Max. 500 mA
Power supply module
Rated input voltage:220 to 240 V AC
Input voltage range:170 to 264 V AC (rms)
Input frequency:47 to 66 Hz (Rating: 50/60 Hz)
Input current: Max. 0.7 A
Fuse rating:3.15 A
Leak current Max. :1 mA
Withstanding voltage:3000 V AC for 1 minute
Insulation resistance:50 MΩ at 500 V DC
Analog Input Module
Input signal 4 to 20 mA
Allowable input current 24 mA
Accuracy ±0.1% of full scale
Overcurrent protection Provided
Data refresh cycle 10 ms
Input step response time 100 ms
Temperature drift Max. ±0.01%/°C
Base module
Operation -40 to +70 °C
Transportation/storage -40 to +85 °C
Dust 0.3 mg/m3 or less
Protection class IP20
Altitude 3000 m or less
Electric field 3 V/m or less (26 MHz to 1 GH
Magnetic field 30 A/m (AC) or less, 400 A/m (DC) or less