3300 XL Standard Extension Cable
075 7.5 meters (24.6 feet)
02 Standard cable with connectorprotector
05 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes
330104 3300 XL 8 mm Probe
M10 x 1 thread,with armor
15 1.5 meter (4.9 feet)
12 Miniature coaxial ClickLocconnector
FluidLoc cable
05 CSA, ATEX, IECEx Approvals
3300 NSv Proximity Probes
330903 3300 NSv Probe
M8X1 thread,without armor
10 1.0 meter (39 in)
01Miniature coaxial ClickLoc connector
with connector protector, standardcable
00 Not required
Controller Module
Clock Speed: 800 MHz – 1.5 GHz
RAM: 2 GB DDR4
Operating Voltage: 24 V DC
Power Consumption: ≤18 W
Isolation: ≥3000 V AC
Ethernet Interfaces:2× Gigabit ports
Discrete I/O: 12–24 V DC
Analog Interfaces: 4–8 channels
Motherboard
Input Voltage: 24 V DC
Backplane Power: 5 V DC
RAM Slots: 2× DDR4 SO-DIMM
Storage: Integrated 16 GB flash
Operating: -40°C to +70°C
Humidity: 5–95% non-condensing
MTBF: >250,000 hours
Processor Module
Operating Voltage: 24 V DC
Power Consumption: <12 W
Input Protection:±40 V peak transient
Digital I/O: 16 channels
Analog I/O (Optional): 4 channels
Ethernet: 2× 10/100 Mbps ports
Serial: RS-232/RS-485 for legacy devices
Fieldbus: PROFIBUS DP
Control Board
Operating Voltage: 24 V DC
Power Consumption: ≤15 W
Voltage Range: 0–10 V DC
Resolution: 12-bit
Channels: ≥8 opto-isolated
Input Signal Level: 24 V DC
ADAPTER BOARD
Electrical Rating:24V DC (±10%)
Compatibility:ACS880-04
Communication Ports:RS485
Operation: 0°C to +55°C
Storage: -40°C to +85°C
PROGRAMMED MODULE
PROGRAMMED
ZINT-571
3AXD50000037997P
Key Function:DCS/SCADA
integrated safety relays
Voltage Supply:24V DC (±10%)
Operating Temp.:-25°C to +60°C
PROGRAMMED MODULE
CCU-24 SP
PROGRAMMED
ZINT-571P
3AXD50000037997P
Key Function:DCS/SCADA
integrated safety relays
Voltage Supply:24V DC (±10%)
Operating Temp.:-25°C to +60°C
CONTROL UNIT
Input Voltage:24V DC (±15%)
Fieldbus: PROFIBUS DP, PROFINET
Digital I/O: ≥16 configurable
Analog I/O: 2x ±10V/4–20mA inputs
Safety I/O: Safe Torque Off
Compatible Drives:ABB ACS880 series
RPBA/PXG01 I/O Boards
Operating Environment:-15°C to +55°C
FIELD SUPPLY BOARD
6RY18030CA05
FIELD SUPPLY
C98043-A7116-L1
SPARE PART
FOR MOTOR CONTROL DC DRIVE
Control Board
PROFIBUS DP
SIMOVERT chassis
Logic Voltage: 24V DC
Analog I/O: ±10V / 4–20mA
Digital I/O: 24V DC terminals
Operating Temp.: 0°C to 55°C
SINGLE MOTOR MODULE
SINAMICS S120
SINGLE MOTOR MODULE
INPUT: DC 600V
OUTPUT: 3AC 400V,
30A FRAME SIZE: BOOKSIZE C-TYPE
INTERNAL AIR COOLING OPTIMIZED
PULSE SAMPLE AND SUPPORT OF
THE EXTENDED SAFETY INTEGRATED FUNCTIONS
INCL. DRIVE-CLIQ CABLE
INVERTER CUVP BOARD
INVERTER CUVP BOARD
Logic Supply Voltage:24V DC ±10%
Multi-core DSP/Vector processor
Temperature Range:0°C to +55°C
EnDAT 2.2, Hiperface DSL¹, TTL/HTL²
SINAMICS S120 FW ≥ V4.8
Control Module
SINAMICS S
spare part
Pre-charging resistor 4R0
Resistance Value: 4Ω (4.0 Ohms)
Resistance:Ω (4.0 Ohms) ±10% tolerance
Power Rating:500 W to 1500 W
Control Board
Input Power: 24V DC
Sensor Interfaces: Analog I/O (0-10V/4-20mA)
ARM/X86-based chipsets
Temperature Range: -20°C to +60°C
Humidity Tolerance: ≤95% (non-condensing)
Inverter drive board
SINAMICS S120 Motor Modules
DC Link Voltage: voltages up to 600–900V
Logic Power Supply: 24V DC ±10%
Real-time IGBT driver control
Operating Temp.: -10°C to +50°C
POWER SUPPLY UNIT
POWER SUPPLY UNIT
CIM PM-IF
SINAMICS spare part
CIM PM-IF for Power Module
PM 240 FSGX CIB,
power supply board and mounting plate
Thyristor Module
A5E00712730
GM150TYP
SINAMICS GM150 (IGBT) 3.3kV
Voltage Class: 3.3 kV (±10%)
X21 Terminal: 24V DC
Capacitor board
SINAMICS S120
Adapter cable 4-pole
for connection of the connector X41
for replacement of the CIB module
with a Control Interface Module (CIM)
is only required for air-cooled Power Modules