Accelerometers
0 1 ¼-28 UNF integral stud
0 0 None
InputVoltage -24 ± 0.5 Vdc.
Bias Current 2 mA nominal.
Output BiasVoltage: -8.5 ± 0.5 Vdc.
3300 XL 11 mm Probe
3300 XL 11 mm Probe
1/2-20 UNFthread
without armor
10 1.0 meter (3.3 feet)
11Miniature coaxial ClickLocconnector
with connectorprotector, FluidLoc cable
05 Multiple Approvals
Order in increments of 0.1 in
Threaded length configurations:
Maximum case length: 9.9 in
Minimum case length: 1.0 in
Example: 2 4 = 2.4 in
Interconnect Cable
Product Type : Interconnect Cable
Model : 16710 - TEIP11-PS I/P Converter, signal converter for standard signals, with power stage
Cable Length Option : 20 - 20 ft
3300 XL 8 mm Proximity Probes
3300 XL 8 mm Probe
M10 x 1 thread
without armor
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
05 0.5 meter (1.6 feet)
02 Miniature coaxial ClickLoc
connector, standard cable
00 Not required
Probe Proximity Vibration
Proximity Vibration Probe
±0.25 mm to ±10 mm
Standard 4-wire or 2-wire
-40°C to +120°C
4-20 mA
3300 XL 11 mm Extension Cable
080 8.0 meters (26.2 feet)
01 Armored cable
05 Multiple Approvals
Outputresistance50 Ω
3300 XL 8 mm Proximity
Tip Diameter: 8 mm
Cable Length: 130 inches (10.8 feet)
Measurement Range: Up to 2 mm (80 mils)
Linear Range: 0.25–2.0 mm (10–80 mils)
Output Sensitivity: -7.87 V/mm (-200 mV/mil)
Frequency Response: 0–10 kHz
16710 Interconnect Cables
3-conductor shielded
22 AWG (0.5 mm2)
armored cable with 3- socket plug at one end,
terminal lugs at the other end
Minimum length of 3.0 ft (0.9 m),
maximum length of 99 ft (30 m).
Cable Length Option in feet : 35 = 35ft
3300 5mm Proximity Probes
330171 3300 5mm Probe
1/4-28 UNFthread, without armor
0 0 = 0.0 in.
Minimum unthreaded length: 20 = 2.0 in
0 5 0.5 meter (1.6 feet)
0 2Miniature coaxial ClickLocconnector
standard cable
0 0 Agency Approval Option
990 Vibration Transmitter
05 0-5 mils pp (0-125 μm pp)
50 5.0 meters (16.4 feet)
70 7.0 meters (23.0 feet)
01 35 mm DIN rail clips
05CSA Division 2, ATEX Zone 0
ATEXZone 2 and includes
ABSmaritime approval
3300 NSv Extension Cable
3300 NSv Extension Cable
060 6.0 meters (19.7 feet)
06 FluidLoc cable without stainlesssteel armor
Extension cabledc resistance
Center conductor: 0.220Ω/m (0.067 Ω/ft)
Shield: 0.066 Ω/m (0.020Ω/ft)
3300 NSv Proximity Probes
330905 3300 NSv Probe
M10X1 thread,without armor
Minimum unthreaded length:80 mm
Minimum length: 130 mm
10 1.0 meter (39 in)
12 Miniature coaxial ClickLoc connector
FluidLoc cable
3300 NSv Extension Cable
060 6.0 meters (19.7 feet)
04With stainless steel armor
withFEP jacket
with connectorprotector
05 Multiple Approvals
Interconnect Cable
Impedance: Probable 50 Ohms
Voltage Rating: ≤30 V DC
Operating Temperature: -40°C to +85°C
Shielding: Dual-layer (foil + braided shield) for robust EMI/RFI protection
Bend Radius: ≥10x cable diameter
3300 XL Standard Extension Cable
065 6.5 meters (21.3 feet)
01 With stainless steel armor, withFEP jacket
00 Not Required
Case ExpansionTransducer Systems
Input Power:+24 Vdc, 30 mA minimum
Input Power:+13.5 to +26 Vdcunregulated
30 mAminimum
Voltage:+1 to +6 Vdc, all models
Output Noise:<10 mV
135613-01 and -11 0.20 V/mm (5.0 V/in)
3300 XL 11 mm Extension Cable
3300 XL 11 mm Extension Cable
080 8.0 meters (26.2 feet)
11 Armored FluidLoc cable
05 Multiple Approvals
Emergency Shutdown Device
Ethernet-6 Ports:10/100 Mbps
Protocol :TCP/IP
Input Range:18-36 Vdc Voltage
Power Consumption:24 W Typical/35 W Maximum
Closed StateImpedance:57 KΩ Maximum
Open StateImpedance:187 KΩ Minimum
Internal WettingVoltage:10-15 Vdc
Input Resistance:150 KΩ Typical
Faulted InputTolerance:±40 V
3300 NSv Proximity Probes
05 0.5 meter (20 in)
02 Miniature coaxial ClickLoc connector
standard cable
00 Not required
Vibration Monitors
DC Input :18~36 Vdc, max 7.5 W
Scale Factorrange:5 to 1000 mV/g
Full scale range: 2 to 80 g peak
Current SinkSource:3.3 mA ± 5%
Open CircuitVoltage:-21 to -24 Vdc
ConfigurableBandpass filter:0.2 Hz to 20 kHz
Supply Voltage :-22.8 to –25.2 Vdc
Maximum RatedCurrent:15 mA
330103 3300 XL 8 mm Probe
330103 3300 XL 8 mm Probe
M10 x 1 thread,without armor
Example: 0 6 = 60 mm
Maximum case length: 250 mm
10 1.0 meter (3.3 feet)
02 Miniature coaxial ClickLocconnector
standard cable
00 Not required
Rack Interface I/O Module
RIM I/O Module with Modem Interface
Voltage: 24V DC (±10%)
Consumption: ≤15W
Analog Inputs:4–20mA
Digital Inputs:24V DC dry contact
RS-485:Modbus RTU @ 115.2kbps max
TRANSDUCER
0 1 ¼-28 UNF integral stud
0 5Multiple approvals (CSA, ATEX, IECEx,)
Sensitivity 2.5 mV/m/s2 (25 mV/g) ±5%.
AmplitudeLinearity ±1% to 735 m/s2 (75 g) peak.
TransverseSensitivity Less than 5% of axial.
Amplitude ofResonantPeak20 dB maximum
Interconnect Cable
Shielding:100% foil/braid shielding
Impedance: 50Ω ±10%
Max Signal Frequency: Up to 20 kHz
Operating Range: –55°C to +250°C
Flexibility: 500+ flex cycles
Bend Radius: 8x cable diameter
Control Transformer Module
Input Voltage:120V AC ±10%
Output Voltage:24V DC regulated
Power Rating: 100VA (typical)
Efficiency: >85% at full load
Isolation: 1500V AC input-to-output
Thermal Protection: Shutdown at >85°C

Copyright Notice © 2004-2024 amikong.com All rights reserved
Disclaimer: We are not an authorized distributor or distributor of the product manufacturer of this website, The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because our company is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply.While many DCS PLC products will have firmware already installed, Our company makes no representation as to whether a DSC PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Our company also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from our company, its distributors, or any other source. Our company also makes no representations as to your right to install any such firmware on the product. Our company will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.